O-substituted tetrahydroxamate derivatives of p-tert-butylcalix[4]arene as receptors for transition and heavy metal cations
PublicationTetrasubstituted O-hydroxamate derivatives of p-tert-butylcalix[4]arene were applied as active materials in ion-selective membrane electrodes and were tested towards Pb-selectivity. The electrodes gave near-Nernstian characteristics for Pb2+ cations. The selectivity coefficients were determined. The influence of plasticizer on the electrode behaviour was studied. The dependence of the chemical structure on selectivity coefficients...
-
Dipodal Tetraamide Derivatives of 1,10-Diaza-18-Crown-6 and Alkylmalonic Acids—Synthesis and Use as Ionophores in Ion Selective Membrane Electrodes
PublicationNovel dipodal derivatives of an 18-membered diaza-crown ether with two diamide chains featuring methylmalonic or butylmalonic acid residues were obtained and tested as ionophores in ion-selective plasticized membrane electrodes. The objective of the study was to identify measurement conditions which ensure the most favorable performance for magnesium ion-selective electrodes. The relationship between the molar lipophilic anion...
-
Measurement of activity coefficients at infinite dilution of organic solutes in the ionic liquid 1-hexyl-1,4-diaza[2.2.2]bicyclooctanium bis(trifluoromethylsulfonyl)imide using gas–liquid chromatography
PublicationBased on gas–liquid chromatography (GLC) retention data, activity coefficients at infinite dilution of 39 different solutes in the ionic liquid 1-hexyl-1,4-diaza[2.2.2]bicyclooctanium bis(trifluoromethylsulfonyl)imide ([HDABCO][NTf2]) have been determined. Measurements covered a broad range of types of organic solutes including alkanes, alcohols, ketones, benzene derivatives and McReynold’s compounds. Activity coefficients were...
-
Calix[4]arene-Thioamides as Ionophores for Transition and Heavy Metal cations
PublicationCalix[4]arene derivatives play an important role as sensing materials in Ion Selective Electrodes(ISEs). Nowadays a high impact is put to control in natural waters the level of toxic heavy metals, like Pb ,Cd, Hg or Cu which may cause the great risk to human health. Our goal was to design and to synthesize ligands possessing ability to bind transition and heavy metal cations. The synthesis, crystal structures,extractive and ionophoric...
-
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 16. Synthesis of 25, 26, 27, 28-tetrakis(piperidinethiocarbonylmethylene)-p-tert-butylcalix[4]arene and its interaction with metal ions
PublicationThe synthesis, characterisation and X-ray crystal structures of p-tert-butyl-calix[4]arenethioamide L and its complex with lead L-Pb2+ is reported. The cation-binding properties in solution have been assessed by liquid-liquid extraction of the metal picrates from water into dichloromethane and by stability constants determination in acetonitrile using UV-absorption spectrophotometry or potentiometry. The compound was used as active...
-
Solid-Contact Ion-Selective Electrodes with Highly SelectiveThioamide Derivatives of p-tert-Butylcalix[4]arene for theDetermination of Lead(II) in Environmental Samples
PublicationThioamide derivatives of p-tert-butylcalix[4]arene were used as ionophores in the development of solid-contact ion-selective electrodes based on conducting polymer poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) which was synthesized by electrodeposition on the glassy carbon electrodes. The typical ion-selective membranes with optionally two different plasticizers [bis(2-ethylhexyl)sebacate (DOS) and 2-nitrophenyl...
-
Measurements of Activity Coefficients at Infinite Dilution for Organic Solutes in the Ionic Liquids N-Ethyl- and N-Octyl-N-methylmorpholinium Bis(trifluoromethanesulfonyl)imide. A Useful Tool for Solvent Selection
PublicationIn recent years, many papers describing ionic liquids (IL) as promising solvents in separation techniques have been published. The conscious choice of appropriate ionic liquid as absorption media in effective extraction of selected types of analytes requires deeper understanding of the analyte−IL interactions. Therefore, intensive research is conducted to determine the values of activity coefficient at infinite dilution, which...
-
Permeation and sorption properties of poly(ether-block-amide) membranesfilled by two types of zeolites
PublicationThe experimental study of transport properties of mixed matrix membranes (MMMs) based on PEBA-4033 with two types of zeolites is reported. Gas (CO2, O2, N2) and vapor (benzene, toluene, methanol, water) permeation measurements were performed using the differential flow permeameter at temperature of 298.15 K and at atmospheric pressure. Gas/vapor permeation was monitored by measuring the changes of the thermal conductivity of carrier...
-
Effectiveness of toluene separation from gas phase using supported ammonium ionic liquid membrane
PublicationAmmonium ionic liquids (ILs) are relatively cheap in synthesis and environmentally benign and despite that they have been very rarely used in gas separation. In this research we used several ammonium ILs as liquid membranes for removal of residual toluene from gas phase. Ionic liquids used in this study were composed of bis(trifluoromethylsulfonyl)imide anion [Tf2N] and trimethylbutylammonium [N1114], trietylbutylammonium [N2224],...
-
A Simplistic Downlink Channel Estimation Method for NB-IoT
PublicationThis paper presents a downlink channel estimation method intended for a Narrowband Internet of Things (NB-IoT) access link. Due to its low computational complexity, this method is well suited for energy-efficient IoT devices, still providing acceptable reception quality in terms of signal-to-noise (SNR) performance. This paper describes the physical layer of NB-IoT within the scope of channel estimation, and also reviews existing...
-
Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis
PublicationLiquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI–MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace® Ultracore™ SuperC18™ (100 × 2.1 mm, 2.5 μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple “dilute & shoot” approach...
-
New bis(azobenzocrown)s with dodecylmethylmalonyl linkers as ionophores for sodium selective potentiometric sensors
PublicationNovel biscrowns 1 and 2 were synthesized from 13-membered azobenzocrown ethers containing bromoalkylenoxy chains in para position relative to the azo group. The synthesized diester molecules are dodecylmethylmalonic acid derivatives differing by the linker length. The synthesized compounds have the potential of being used as sodium ionophores in ion-selective electrodes. They were characterized and used as ionophores in classic...
-
Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo-15-crown-5) derivatives
PublicationGlassy carbon electrodes modified by conductive polymers and membrane with derivatives of bis(benzo-15-crown-5) were tested as solid contact ion selective electrodes for K+ ions concentration determination. PEDOT with PSS, Cl- and ClO4- counter ions was electrochemically deposited onto glassy carbon substrates using four different electrochemical approaches (potentiostatic, galvanostatic, potentiodynamic and potentiostatic pulses)....
-
Head-Space SPME for the Analysis of Organophosphorus Insecticides by Novel Silica IL-Based Fibers in Real Samples
PublicationThis work demonstrates the suitability of a newly developed ionic liquid (IL)-based silica SPME fiber for the determination of seven organophosphorus insecticides in cucumber and grapefruit samples by headspace solid-phase microextraction (HS-SPME) with a gas chromatography–flame ionization detector (FID). The sol-gel method released four different sorbent coatings, which were obtained based on a silica matrix containing ILs immobilized...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...