Filters
total: 60
filtered: 58
Chosen catalog filters
Search results for: constructed wetlands
-
The use of constructed wetlands for the treatment of industrial wastewater
PublicationConstructed wetlands are characterized by specific conditions enabling simultaneous various physical and biochemical processes. This is the result of specific environment for the growth of microorganisms and hydro-phytes (aquatic and semiaquatic plants) which are capable of living in aerobic, anaerobic and facultative anaerobic conditions. Their interaction contributes to the intensification of oxidation and reduction responsible...
-
Kinetics of nitrogen removal processes in constructed wetlands
PublicationThe aim of this paper is to present a state-of-the-art review of the kinetics of nitrogen removal in constructed wetlands. Biological processes of nitrogen removal from wastewater can be described using equations and kinetic models. Hence, these kinetic models which have been developed and evaluated allow for predicting the removal of nitrogen in treatment wetlands. One of the most important, first order removal model, which is...
-
Constructed wetlands systems for wastewater treatment in Poland
PublicationOczyszczalnie hydrofitowe mogą stanowić interesującą alternatywę dla konwencjonalnych rozwiązań gospodarki ściekowej na terenach o rozproszonej zabudowie. Celem pracy była ocena działania i skuteczności usuwania zanieczyszczeń w hybrydowych systemach hydrofitowych pracujących w rejonie Gdańska, w klimacie umiarkowanym.Technologiczne rozwiązanie składające się z osadnika gnilnego oraz złoża hydrofitowego z podpowierzchniowym przepływem...
-
Sewage gardens - constructed wetlands for single family households
PublicationDuring the last 30 years the increase of interest in low-cost decentralized and small wastewater treatment plants (WWTP) is observed in Europe. For this purpose sand filters, stabilization ponds, mini reactors with activated sludge, trickling filters and treatment wetlands are used. Among the listed facilities treatment wetlands (TWs) offer effective and reliable treatment efficiency, being at the same time low-cost and simple...
-
Experience of hybrid constructed wetlands operation in Gdansk region
PublicationThe investigation were carried out at five local hybrid constructed wetlands (HCWs), which secured biological treatment of domestic wastewater generated from 15 to 600 pe. Based on over two years monitoring it was indicated that HCWs ensured very effective removal of organic matter from 74.9 to 95.5 COD % in wild range of loadings (1.5 - 17.0g COD/ m3day). Efficiency of total nitrogen removal varied significantly from 23.4 two...
-
Recent developnents in wastewater treatment in constructed wetlands in Poland
PublicationNowadays more than 100 constructed wetlands are in operation in Poland. Most of them are one stage wetland systems with horizontal subsurface flow. Such constructed wetlands ensure efficient removal of organic matter (BOD5, CODCr) and suspended solids but efficiency of nitrogen compounds removal in many cases is insufficient.In the period from 1995 to 2003 measurements of removal of contaminations in 11 individual pilot household...
-
Pathways of nitrogen compounds depletion in hybrid constructed wetlands
PublicationHybrid Constructed Wetlands are composed of two or more filters with mixed flow direction of sewage. Apparently in the HCWS the benefits of both types of bed are merged, resulting in better effluent quality (organic and nitrogen componds removal). Such heterogeneous environment creates possibilities for different ways of nitrogen "disappearing". The objective of the present study was to compare the removal of nitrogen with accompanying...
-
Operation of multistage constructed wetlands systems in temporary climate
PublicationThe investigation were carried out at two different hybrid constructed wetlands, which treated municipal sewage after mechanical treatment from small villages in Pomeranian Region. In all facilities first step of biological treatment were horizontal flow beds. The main difference concern configuration of the facilities and sewage distributions systems into vertical flow beds. The measurement period was divided into vegetation...
-
Influence of oxygenation of constructed wetlands for effectiveness of contaminants removal
PublicationBadania prowadzono w trzech hybrydowych systemach hydrofitowych (HSH): Wiklinie, Wieszynie i Wiedersbergu. Obiekty charakteryzowały się różnym ładunkiem doprowadzanej SO. Określenie jakości SO w ściekach polegało na przeprowadzeniu analizy specjacji substancji organicznej zgodnie z metodyką podaną w niemieckich wytycznych ATV-131. Na podstawie analizy frakcji ChZT wykazano, że szybkość rozkładu SO (k) w złożach była determinowana...
-
Sesonal changes of contamination removal in constructed wetlands system.
PublicationBadania prowadzona w dwch oczyszczalniach hydrofitowych zasilanych ściakami bytowo-gospodarczymi.Analizowany okres pomiarowy podzielono na sezon wegetacyjny (od kwietnia do października) oraz poza wegetacyjny (pozostałe miesiące).Uzyskane rezutlaty pozwoliły na oceną skuteczności usuwania zanieczyszczeń oraz wyznaczenie szybkości usuawania zanieczyszczeń w obu analizowanych okresach.
-
Spetiation of organic matter in Vertical Flow Constructed Wetlands
PublicationThe object of the research were VFCWs which are a component of biological treatment of two hybrid hydrophyte systems located in Wieszyno and Wiklino, close to Słupsk, Poland. The facilities that are subject to analyses are unified in terms of structure (filtration material, depth of the bed and time of operation), but they differ in organic matter load, amounting respectively to: 8.0 gCOD/m2day and 31.0 gCOD/m2day.The intensity...
-
Review on mechanisms and efficiency of removal of microbiological contaminants in constructed wetlands
PublicationConstructed wetlands (CW) have been considered as a waste and a stormwater treatment systems for small communities or for areas with unsteady sewage flow conditions. Several investigations were undertaken for estimation suspended solids, organic matter and nutrients efficiency removal but only few focused on retention of microorganisms in constructed wetlands. In this review mechanisms of elimination of viruses, indicator bacteria...
-
Influence of configurations of the beds on contaminations removal in hybrid constructed wetlands.
PublicationThree hybrid constructed wetlands in configuration HF-VF-HF in Poland and one with another configuration VF-HF-Pond in Gremany were analysed. These hybrid constructed wetlands provide the second stage biological treatment. They are located in Pommerania region, in Sarbsk, Wiklino and Wieszyno, and their capacities are 29.7, 18.6 and 24.5 m3/day, respectively. The analysed system in Germany in Waizenfeld (Gemeinde Pommelsbrunn,...
-
Treatment of landfill leachate by constructed wetlands: three case studies
PublicationThe performance of three CW systems treating landfill leachate, two located in northern Poland (Szadółki near Gdańsk and Gatka near Miastko) and one in southern Sweden (Örebro), is discussed. The CWs differ in size, hydraulic regime, type of hydrophytic plants and type of leachate pre-treatment before discharging to the CW. The CW in Szadółki consists of two parallel beds with sub-surface, horizontal flow of leachate (HSSF) planted...
-
Constructed wetlands for landfill leachate treatment - perspectives of application in Poland
PublicationWody odciekowe z wysypisk odpadów komunalnych charakteryzują się wysokimi stężeniami zanieczyszczeń specyficznych. Do oczyszczania odcieków stosowane są metody utleniania, w których wykorzystuje się tlenowe lub beztlenowe procesy mikrobiologiczne, a także utlenianie chemiczne oraz techniki membranowe.Alternatywą dla wymienionych rozwiązań jest zastosowanie do oczyszczania odcieków metody hydrofitowej z wykorzystaniem złóż gruntowych...
-
Distribution of heavy metals in vegetation of constructed wetlands in agricultural catchment
PublicationW artykule przedstawiono wyniki pomiarów zawartości wybranych metali ciężkiech w nadziemnych i podziemnych częściach trzech gatunków roślin hydrofitowych zasiedlających ekosystem oczyszczalni hydrofitowej w Bielkowie k. Gdańska.
-
Polish constructed wetlands performance and transfer of results into Alpine environment.
PublicationPrzyjmuje się, że oczyszczalnia hydrofitowa opisana może być równaniem kinetyki reakcji pierwszego rzędu. Uzyskano z danych doświadczalnych, że współczynnik kinetyki reakcji k jest uzależniony od temperatury oczyszczalnych ścieków w gruncie porośniętym trzciną. Można więc wyznaczyć przebieg funkcji k(T), gdzie k jest współczynnikiem kinetyki reakcji, a T-temperaturą ścieków. Można więc niskie wartości k uzyskane w warunkach...
-
Development of models for nitrogen-removal processes in subsurface flow constructed wetlands
PublicationThis paper summarizes recent progress in modelling approach of subsurface flow constructed wetlands (SSF CWs), focusing on nitrogen removal processes.
-
Nitrogen pathways during sewage treatment in constructed wetlands in temporary climate
PublicationThe objectives of this paper is to estimate the role and quantity of the unit process responsible for removal or/and retention of nitrogen in different types of constructed wetlands in vegetation season and outside vegetation season. To estimate the role of the plant two objects inhabited one with willow and the other with reed were selected to assessment. Among anthers it was indicated that the concentrations of contamination...
-
Performance of subsurface vertical flow constructed wetlands receiving municipal wastewater.
PublicationPrzedstawiono skuteczność pracy oczyszczalni hydrofitowych z pionowym przepływem ścieków. Wsazano jak usuwanie azotu uzależnione jest od temperatury, podobnie usuwanie ładunkuu BZT5. Wskazano na różnice w pracy oczyszczalni w okresie lata i zimy.
-
Efficiency of pollutant removal by five multistage constructed wetlands in a temperate climate
PublicationIn recent years, an increase in interest in hybrid constructed wetland systems (HCWs) has beenobserved. These systems are composed of two or more filters with different modes of sewage flow.Based on over eight years of monitoring, carried out at five local HCWs located in the PomeraniaRegion of Northern Poland, the effective removal of organic matter (from 74.9 to 95.5% COD) in theloading range 1.5-17.0 g COD·m-2·d-1 was confirmed....
-
Effectiveness of pollutants removal in hybrid constructed wetlands – different configurations case study
PublicationIn recent years, an increase in interest in hybrid constructed wetland systems (HCWs) has been observed. The aim of the paper is to compare different HCW configurations in terms of mass removal rates and efficiency of pollutants removal. Analysed data have been collected at multistage constructed wetlands in Poland, which are composed by at least two beds: horizontal subsurface flow (SSHF) and vertical subsurface flow (SSVF). The...
-
Kinetics of pollutants removal in vertical and horizontal flow constructed wetlands in temperate climate
PublicationThis paper reports a comparative study on kinetics of organic matter expressed as BOD5 and nitrogen removal in constructed wetlands operated in Poland. Analyzed data were collected at eight wetland systems, composed of subsurface flow beds: horizontal flow (HF) and vertical flow (VF), in different number and sequences. The analysis involved particularly mass removal rates (MRR) and first-order removal rate coefficients of BOD5...
-
25 years of research and experiences about the application of constructed wetlands in southeastern Poland
PublicationThis paper is a review of research and experiences related to the application of constructed wetland systems (CWs) in southeastern Poland in 1992–2016. On the basis of literature data, a comparison between pollutant removal efficiencies of one-stage and hybrid CWs was made. Some problems regarding the operation of these treatment plants were also presented. Data from various facilities indicate that one-stage CWs with horizontal...
-
Dependence between quality and removal effectiveness of organic matter in hybrid constructed wetlands
PublicationW procesie oczyszczania ścieków w Vertical Flow Constructed Wetland (VF-CW) jednym z czynników jest dopływ tlenu. Niewystarczający dopływ tlenu do złoża może być przyczyną braku efektywności usuwania zanieczyszczeń, a więc wskazywać na niewłaściwą eksploatację obiektu.Obiekty badań stanowiły złoża pionowe stanowiące jeden z elementów biologicznego oczyszczania dwóch hybrydowych systemów hydrofitowych zlokalizowanych w Wieszynie...
-
Influence of COD-fractions on removal effectiveness and accumulation of organic matter in constructed wetlands
PublicationW pracy wykazano, że efektywność usuwania substancji organicznej doprowadzanej w ściekach bytowo-gospodarczych do złóż hydrofitowych zależy od rodzaju frakcji substancji organicznej oraz ich stężeń. Na podstawie analizy poszczególnych frakcji ChZT (rozpuszczonych związków organicznych biologicznie łatwo- i nierozkładalnych oraz zawiesin organicznych biologicznie wolno- i nierozkładalnych) wykazano, że na akumulację substancji organicznej...
-
Efficiency of Wastewater Treatment in Single-Family Constructed Wetlands in Kaszuby Lake District
PublicationIn the paper results of investigation upon three different configurations of single family treatment wetlands were presented. It was indicated that the application of treatment wetlands for single family effluent is a effective and sustainable solution for wastewater treatment in the rural areas. In spite of the receiving higher concentration of pollutants in comparison to the TWs operated in Europe and USA analysed TWs ensure...
-
Quantitatively and qualitatively characteristic of organic matter in sewage after treatment in constructed wetlands
PublicationNajczęstszym kryterium oceny skuteczności oczyszczania ścieków jest efektywność usuwania zanieczyszczeń. Jednakże oczyszczone ścieki zawierają pewne ilości substancji organicznej niepodatnej na rozkład biologiczny tzw. refrakcyjnej.Organiczne substancje refrakcyjne to przede wszystkim kwasy humusowe, które swoja obecnością w wodzie mogą pogarszać jej właściwości i utrudniać procesy uzdatniania do celów konsumpcyjnych. Wykazano,że...
-
The Oxygen Transfer Capacity of Submerged Plant Elodea densa in Wastewater Constructed Wetlands
Publication -
Application of vertical flow constructed wetlands for highly contaminated wastewater treatment: preliminary results
PublicationBasing on quantitative and qualitative characteristics of reject waters (RWC) generated during dewatering of digested sewage sludge on centrifuges in conventional WWTP and municipal landfill leachate (LL), the pilot constructed wetlands for treatment of both types wastewater were designed and built. In the paper the conception, design and assumed treatment efficiencies of the pilot plants are presented. The water balance of the...
-
Distribution and removal efficiency of heavy metals in two constructed wetlands treating landfill leachate
PublicationThe results of heavy metals (Fe, Mn, Zn, Ni, Cu, Cr, Pb, Cd) removal and partitioning between aqueous and solid phases at two wetlands (TWs) treating municipal landfill leachates are presented. One of the TWs is a surface flow facility consisting of 10 ponds. The other TW is a newly constructed pilot-scale facility consisting of three beds with alternately vertical and horizontal sub-surface flow. The metals concentrations were...
-
Removal of selected sulfonamides and sulfonamide resistance genes from wastewater in full-scale constructed wetlands
PublicationSulfonamides are high-consumption antibiotics that reach the aquatic environment. The threat related to their presence in wastewater and the environment is not only associated with their antibacterial properties, but also with risk of the spread of drug resistance in bacteria. Therefore, the aim of this work was to evaluate the occurrence of eight commonly used sulfonamides, sulfonamide resistance genes (sul1–3) and integrase genes...
-
Nitrogen removal in vertical flow constructed wetlands: influence of bed depth and high nitrogen loadings
PublicationThe aim of the study was to evaluate the nitrogen removal and its effects on the plant’s growth and leaves morphology. using two subsurface vertical flow (VF bed), with different depths (0.24 m2 × 0.70 m; 0.24 m2 × 0.35 m) and nitrogen load increments. The VF bed were planted with Vetiveria zizanioides, filled with light expanded clay aggregates (Leca®NR 10/20) and fed in parallel mode with synthetic wastewater. High ammonium nitrogen...
-
Hybrid constructed wetlands for the National Parks in Poland - a case study, requirements, dimensioning, preliminary results
PublicationWater and wastewater management, especially in rural areas, greatly affects loads of nutrients discharged to the Baltic Sea. In Poland, this management is unbalanced because of the dispersed development and in many locations con struction of sewerage system is uneconomic or even impossible. For this reason, a significant part of sewage from single-family houses in rural areas must be discharged into domestic sewage systems. The...
-
Application of subsurface vertical flow constructed wetlands to reject water treatment in dairy wastewater treatment plant
PublicationThe paper presents the effects of applying subsurface vertical flow constructed wetlands (SS VF) for the treatment of reject water generated in the process of aerobic sewage sludge stabilization in the biggest dairy wastewater treatment plant (WWTP) in Poland. Two SS VF beds were built: bed (A) with 0.65 m depth and bed (B) with 1.0 m depth, planted with reeds. Beds were fed with reject water with hydraulic load of 0.1 m d-1 in...
-
Molecular transformation of dissolved organic matter in manganese ore-mediated constructed wetlands for fresh leachate treatment
PublicationThe organic matter (OM) and nitrogen in Fresh leachate (FL) from waste compression sites pose environmental and health risks. Even though the constructed wetland (CW) can efficiently remove these pollutants, the molecular-level transformations of dissolved OM (DOM) in FL remain uncertain. This study reports the molecular dynamics of DOM and nitrogen removal during FL treatment in CWs. Two lab-scale vertical-flow CW systems were...
-
The treatment of wastewater containing pharmaceuticals in microcosm constructed wetlands: the occurrence of integrons (int1–2) and associated resistance genes (sul1–3, qacEΔ1)
PublicationThe aim of this study was to analyze the occurrence of sulfonamide resistance genes (sul1–3) and other genetic elements as antiseptic resistance gene (qacEΔ1) and class 1 and class 2 integrons (int1–2) in the upper layer of substrate and in the effluent of microcosm constructed wetlands (CWs) treating artificial wastewater containing diclofenac and sulfamethoxazole (SMX), which is a sulfonamide antibiotic. The bacteria in the substrate...
-
Correction: Białowiec, A., et al. The Oxygen Transfer Capacity of Submerged Plant Elodea densa in Wastewater Constructed Wetlands. Water, 2019, 11, 575
Publication -
30 years of treatment wetland application in poland- progress and reserch
PublicationThe experiences with design and operation of constructed wetlands in the Pommerania region during last 30 years followed by carried out investigations of treatment processes lead to the following conclusions:First applications of constructed wetlands for biological sewage treatment were made in 1984-92. The later implementations of multi-stage constructed wetlands in the individual household and local scale enable wastewater treatment...
-
History and Perspective of Treatment Wetland in Poland – Part One: Lesson learned
PublicationEarly implementation of treatment wetlands under supervision of the researchers from were quite promising. The constructed facilities ensured effective wastewater treatment and sludge dewatering. In the next years a number of treatment wetland s systems were constructed without following the designing principles and left without proper maintenance. In the consequence this lead to unsatisfactory treatment results. Investigations...
-
Evaluation of respiration capacity of VF in hybrid constructed wetland systems.
PublicationThree VF-beds operating in hybrid constructed wetlands in configuration HF-VF-HF were analysed. These hybrid constructed wetlands provide the II stage biological treatment. They are located in Pommerania voivodship, in Sarbsk, Wiklino and Wieszyno, and their capacities are 29.5, 14.2 and 21.6 m3/d, respectively. The article focuses on performance and operation of VF-CW plants during one year. Based on removal of organic matter...
-
Removal and speciation of heavy metals in the constructed wetland treating landfill leachate
PublicationThe results of heavy metals removal and speciation of metals at two treatment wetlands receiving landfill are discussed. The first TW is a surface flow facility consisting of 10 ponds. The next TW is a newly constructed pilot-scale facility consisting of three beds with alternately vertical and horizontal sub-surface flow. The metals concentrations were analysed in leachate(both TWs) and bottom sediments (surface flow TW). Seasonal...
-
The newest researches and applications of treatment wetlands in sewage sludge management
PublicationIn the paper the newest researches and applications of treatment wetlands conducted by re-searchers of Civil and Environmental Faculty are presented. Among others it was proved that this technology could be successfully implemented for highly polluted wastewater treatment. Within the research project two multistage treatment wetlands, one for landfill leachate and the second for reject water from digested sewage sludge centrifugation,...
-
Landfill leachate treatment at a pilot plant using hydrophyte systems
PublicationConstructed wetlands can provide an effective and economical solution to landfill leachate treatment. In the article the performance of a CW for leachate treatment, consisting of two horizontal flow constructed wetlands (HF-CW) beds, working at the municipal landfill in Gdansk-Szadolki in the period 2004-2005 is being discussed. The plant has been operating since 2001. Clogging problems and surface flow occurred in the system...
-
The Concept of Construction of Hybrid Constructed Wetland for Wastewater Treatment in Roztocze National Park
PublicationRoztocze National Park (RNP) is one of 23 national parks in Poland. It was created in 1974 both to protect the natural and cultural heritage as well as to share the park area for science, education and tourism. In caring for the environment, the park removed asbestos coverage, performs thermo-modernization using renewable energy sources by the installation of solar panels and photovoltaic cells on the roofs of buildings, and pellet...
-
Potential and limits of landfill leachate treatment in a multi-stage subsurface flow constructed wetland – evaluation of organics and nitrogen removal
PublicationConstructed wetlands have potential of treating wastewater of poor biodegradability. The performance of a multistage sub-surface flow wetland treating municipal landfill leachate was assessed during three years of operation. During the study three research periods with different operation conditions were established. The hydralic loads, operation mode of vertical flow beds and type of treated wastewater (raw leachate – leachate...
-
Present state and future of wetland technology in environmental protection in Poland
Publication: Polish experience with implementation and operation of constructed wetland systems are presented. Wetland technology can be applied for the removal of contaminants from aerial sources, point sources and for utilization of sewage sludge.From 1994-2002 monitoring of three different facilities for water protection was carried out. Substantial im-provement of water quality after implementation of the facilities was observed.From...
-
Application of vertical flow cw for highly contaminated wastewater treatment
PublicationBasing on quantitative and qualitative characteristics of reject waters generated during digested sewage sludge dewatering on centrifuges in conventional WWTP (RWC) and municipal landfill leachate (LL), the pilot constructed wetlands for treatment of both types of highly contaminated wastewater were designed. In the paper the characteristics of the pilot plants and assumed treatment efficiencies are presented. According to the...
-
Coupling transformation of carbon, nitrogen and sulfur in a long-term operated full-scale constructed wetland
PublicationThe coupling transformation of carbon, nitrogen and sulfur compounds has been studied in lab-scale and pilot-scale constructed wetlands (CWs), but few studies investigated full-scale CW. In this study, we used batch experiments to investigate the potentials of carbon, nitrogen and sulfur transformation in a long-term operated, full-scale horizontal subsurface flow wetland. The sediments collected from the HSFW were incubated for...
-
The influence of humic substances in treated sewage on the quality of surface waters
PublicationAt present the evaluation of WWTP effectiveness is based upon organic matter and nutrients removal. Recently it was found out that sewage treatment leads to formation of resistant to biochemical degradation organic compounds, similar to humic acids. The humic acids formed during sewage treatment process play diversified functions when discharged to surface waters - for instance they can act as carriers of hydrophobic organic pollutants...