Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublicationThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublicationThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Theoretical analysis of current induced by high-energetic radiation in dielectric materials
PublicationW pracy poddano analizie mechanizmy generacji i rekombinacji nośników ładunku w obecności wysokoenergetycznego promieniowania. Przedstawiono zależności gęstości prądu elektrycznego od natężenia promieniowania i napięcia polaryzujacego próbkę.
-
European Society of Hypertension Working Group on Obesity Obesity-induced hypertension and target organ damage: current knowledge and future directions
Publication -
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Analysis of unsteady flow forces on the thermowell of steam temperature sensor
PublicationIn this paper, 3D numerical analysis of unsteady flow forces acting on the measuring sheath of steam temperature is presented. According to that purpose, the CFD (Computation Fluid Dynamic [1]) approach has been used. The nonstationary of fluid acting on the measuring sheath such as: Strouhal frequency, amplitude of pressure, structure of vortex, peak of pressure, field of pressure, field of velocity etc. are studied analytically...
-
Jednoelektronowy atom Diraca w słabym polu magnetycznym
PublicationW rozprawie przedstawiono opis wpływu zewnętrznego stałego, słabego, jednorodnego pola magnetycznego na jednoelektronowy atom Diraca. Wykorzystując funkcje gęstości ładunku elektrycznego oraz gęstości prądu elektrycznego, rozważono procesy indukowania się w atomie dodatkowych elektromagnetycznych momentów multipolowych. Dokonano analizy indukowanego momentu dipolowego, w wyniku której uzyskano wyrażenie dla magnetyzowalności atomu....
-
Paweł Możejko dr hab.
People -
Magnetism from fundamentals to spintronics 22/23
e-Learning Courses1. Basic magnetic quantities2. Magnetism of atoms and molecules, atoms in external magnetic fields3. Solid state magnetism, types of magnetic materials (dia-, para-, and ferromagnetism)4. Ferromagnetism and domain structures5. Magnetism of small particles, single domain particles (StonerWohlfarth model), thin films6. Experimental techniques of magnetic properties and magnetisation state determination. Domain structurevisualisation...
-
Tobacco Induced Diseases
Journals -
The effect of current delay angle on tripping of residual current devices
PublicationPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
New synthesis method of sword-sheath structured carbon nanotubes
Publication -
Detection of high frequency current components by residual current devices
PublicationThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Current divider-based nanosecond high current pulse measuring systems
PublicationThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Time-current tripping characteristics of RCDs for sinusoidal testing current
PublicationLow-voltage electrical installations are verified initially – before being put into operation, as well as periodically – during their utilization. According to the IEC standards, the scope of the verification includes measurements of both the tripping current and the disconnection time of residual current devices (RCDs). Experiences in RCDs testing show that disconnection times of two or more similar RCDs can be quite different....
-
A current-controlled FET
PublicationA novel semiconductor device, viz., Horizontally-Split-Drain Current-Controlled Field-Effect Transistor (HSDCCFET) with two control electrodes is proposed in this works. For the sake of brevity, the device can be called a CCFET. Operating principle of the proposed transistor is based on one of the galvanomagnetic phenomena, the Biot-Savart-Laplace law and a Gradual Channel Detachment Effect (GCDE). The transistor is dedicated...
-
Immunity of residual current devices to the impulse leakage current in circuits with variable speed drives
PublicationThis paper concerns reliability of supply in variable speed drive circuits with residual current devices. During normal operation of these circuits high value of leakage current causes unwanted tripping of residual current devices. Immunity of residual current devices to the impulse leakage current should be evaluated. The system for testing of residual current devices and results of the test are presented
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027639791]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027636471]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [603073002763621]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027639941]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027638801]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027633201]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [603073002763401]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027635341]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027638361]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027633341]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027638941]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027635721]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027639221]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027638001]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027634551]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [603073002763131]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027633421]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Nerve sheath tumor, NOS - Female, 15 - Tissue image [6030730027632141]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Robert Bogdanowicz dr hab. inż.
PeopleRobert Bogdanowicz received his Ph.D. degree with honours in Electronics from the Gdansk University of Technology. He worked as a post-doc researcher in Ernst-Moritz-Arndt-Universität Greifswald Institut für Physik. He has initiated optical emission imaging of muti-magnetron pulsed plasma and contributed to the development of antibacterial implant coatings deposited by high-power impulse magnetron sputtering. He moved back to...
-
Fibroma of tendon sheath - Male, 30 - Tissue image [6180730013783931]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fibroma of tendon sheath - Male, 30 - Tissue image [6180730013788931]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fibroma of tendon sheath - Male, 30 - Tissue image [6180730013782401]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multiple output CMOS current amplifier
PublicationIn this paper the multiple output current amplifier basic cell is proposed. The triple output current mirror and current follower circuit are described in detail. The cell consists of a split nMOS differential pair and accompanying biasing current sources. It is suitable for low voltage operation and exhibits highly linear DC response. Through cell devices scaling, not only unity, but also any current gains are achievable. As...
-
Fibroma of tendon sheath - Male, 30 - Tissue image [618073001378831]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fibroma of tendon sheath - Male, 30 - Tissue image [6180730013787731]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Earthquake-Induced Structural Pounding
PublicationEarthquake-induced structural pounding between insufficiently separated build-ings, or bridge segments, has been repeatedly observed during ground motions. The reports after earthquakes indicate that it may lead to some local damage in the case of moderate seismic events or may result in considerable destruction or even collapse of colliding structures during severe ground motions. Pounding in build-ings is usually caused by the...
-
Monitoring of current collectors on the railway line
PublicationProper cooperation the current collectors and the overhead line is a pre-requisite for reliable and safe operation of railway transport. Instances of maladjustment and, in some cases, damage to the current collectors, occur between periodic inspections of the rolling stock. In order to detect such anomalies quickly, the test stand was developed, with the aim of monitoring the technical state of the current collectors under operating...
-
Leakage Current Measurements of Surge Arresters
PublicationThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...