Filters
total: 633
Search results for: MAGNETIC MEASUREMENTS
-
Isolation of the relative decrease in magnetic permeability contribution to reluctance of an open magnetic circuit based on stray field measurements
PublicationThe goal of the study was to evaluate a relative decrease in magnetic permeability in open magnetic circuits based on stray magnetic field measurements. The boundary element method was used to simulate magnetic circuits with variable geometry and variable magnetic permeability. The simulated magnetic circuits were rectangular or bone-shaped flat samples. Reluctance was increased in the middle of the samples resulting in leakage...
-
Analysis of the influence of ferromagnetic contaminations in plastics on the measurements of disturbances of magnetic field of the Earth
PublicationPlastics can be contaminated with small particles or filings with ferromagnetic properties. These contaminations cause significant disturbances in the magnetic field in the case of taking measurements of very low magnetic fields. The analysis of the influence of contaminated plastics on magnetic measurements is presented in this paper.
-
The influence of the geographic positioning system error on the quality of ship magnetic signature reproduction based on measurements in sea conditions
PublicationIn previous studies, the authors performed the magnetic signature reconstruction of the marine ship Zodiak as part of the measurement campaign focused on recording magnetic data and the relative position of a ship during its passage over a magnetometer immersed on the testing ground. A high degree of representation of the magnetic signature was obtained. However, the recorded measurement data revealed new patterns of the multidipole model...
-
The magnetic field measurements in selected places of the industrial building
Open Research DataThe dataset is part of a comprehensive study on the assessment of the electromagnetic field intensity in a building of an operating industrial plant. Detailed results of magnetic field measurements, carried out in selected places of this building, are presented.
-
Measurements of drive system properties of the "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Open Research DataTests of the drive system of the ultra-fast robot "SpeedLine magnetic" for labeling with the IML method were carried out in order to analyze the influence of the operating parameters of the drive system on the correctness and quality of the drive system.
-
Measurements of the mechanical system properties of "SpeedLine magnetic" ultra-fast robot prototype for IML labeling
Open Research DataThe mechanical system tests of the high-speed IML labeling robot "SpeedLine Magnetic" were carried out in order to analyze the effects of the drive system's operating parameters on vibration and noise.
-
Measurements of power supply system properties of "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Open Research DataTests of the power supply system of "SpeedLine magnetic" ultra-fast industrial robot for IML labeling were carried out to analyze the effect of the active power filter (APF) parameters on the power quality. at the target duty cycle. Tests were performed with the target duty cycle. Linear synchronous motors with permanent magnets were used to drive...
-
Influence of plastic deformation on stray magnetic field distribution of soft magnetic steel sample
PublicationThe effect of various combinations of conditions, i.e., presence of the Earth’s magnetic field during and after deformation on the distribution of stray magnetic field of S355 steel sample, which is locally deformed, was investigated. Some of the stages of the experiment were carried out in zero magnetic field. Compensation of the Earth’s magnetic field was obtained by the application of a pair of Helmholtz coils. These coils are...
-
Analysis of magnetic field of Helmholtz's coils
PublicationThe 3-axis fluxgate magnetometer requires conducting a precise calibration in the magnetic field whose value is determined and which is characterized by the high uniformity of the distribution of the field, especially along the axis of the sensors. The generation of the magnetostatic field characterized by the high uniformity, can be achieved by using the Helmholtz's coils. The requirements of the uniformity of distribution of...
-
System of wireless magnetic sensors for detection and identification of ferromagnetic vehicles
PublicationThe paper presents the results of deformation of the Earth's magnetic field by land vehicles. Basing on the analysis of the shape of the magnetic field deformation, it is possible to detect and identify a vehicle. In order to eliminate the interference of the Earth's magnetic field by the environment, the measurements were performed in a differential configuration. Under a development project a wireless system of magnetic sensors...
-
Compensation of magnetic disturbances caused by sensors in a differential magnetometric system
PublicationStudy of low magnetic fields necessitates the use of precision magnetometers working in a differential system. Minimization of this error is a substantial issue in the case of magnetometers working in a differential system on a mobile platform. The compensation method of heading error consists in taking measurements of changes in magnetic induction with the use of the tested magnetometer for various locations of the sensor in relation...
-
Determination of Mechanical Properties of P91 Steel by Means of Magnetic Barkhausen Emission
PublicationIn this work, an attempt at determination of mechanical properties by means of a method based on magnetic Barkhausen emission measurements was proposed. The specimens made of P91 steel were subjected to creep or plastic flow which were interrupted after a range of selected time periods in order to achieve specimens with an increasing level of strain. Subsequently, measurements of magnetic Barkhausen emission were carried out, and...
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublicationThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...
-
Research of leakage magnetic field in deenergized transformer
PublicationThe article deals with the issue of the numerical analysis of the magnetic field occurring around the transformer after it has been powered down. The main goal of this analysis was to examine if it is possible to identify the residual fluxes in the transformer legs based on this fields’ measurements. It was also intended to determine the type and the location of magnetic sensors. Numerical analysis of the magnetic field was performed....
-
Analysis of magnetic field of Hemholtz's coils and ferromagnetic objects
PublicationThe 3-axis fluxgate magnetometer requires conducting a precise calibration in the magnetic field whose value is determined and which is characterized by the high uniformity of the distribution of the field, especially along the axis of the sensors. The generation of the magnetostatic field characterized by the high uniformity, can be achieved by using the Helmholtz's coils. The requirements of the uniformity of distribution of...
-
The electromagnetic field intensity in industrial buildings
Open Research DataThe dataset contains the results of measurements of electromagnetic fields, separately electric and magnetic, carried out at selected places in the building of an operating industrial enterprise.
-
Low-Dimensional Magnetic Semimetal Cr0.65Al1.35Se3
PublicationWhile exploring novel magnetic semiconductors, the new phase Cr0.65Al1.35Se3 was discovered and characterized by both structural and physical properties. Cr0.65Al1.35Se3 was found to crystallize into orthorhombic CrGeTe3-type structure with space group Pnma (no. 62). Vacancies and mixed occupancies were tested, and the results show that one of the 4c sites accommodates a mixture of Cr and Al atoms, while the other 4c site is fully...
-
Spectroscopic and magnetic studies of highly dispersible superparamagnetic silica coated magnetite nanoparticles
PublicationSuperparamagnetic behavior in aqueously well dispersible magnetite core-shell Fe3O4@SiO2 nanoparticles is presented. The magnetic properties of core-shell nanoparticles were measured with use of the DC, AC magnetometry and EPR spectroscopy. Particles were characterized by HR-TEM and Raman spectroscopy, showing a crystalline magnetic core of 11.5 ± 0.12 nm and an amorphous silica shell of 22 ± 1.5 nm in thickness. The DC, AC magnetic...
-
Investigation of magnetic order in a new intermetallic compound Nd2PtGe3
PublicationIn the present study we report a successful synthesis of the new intermetallic compound Nd2PtGe3 by an arc-melting method. The powder X-ray diffraction analysis indicates that this compound crystallizes in an disordered variant of the AlB2-type structure (space group P6/mmm, no. 191) with lattice parameters a = 4.2455 Å and c = 4. 1933 Å. The compound exhibits a cluster-glass transition below Tf = 2.9 K, characterized through ac...
-
Magnetic field maps of an astable multivibrator in frequency range from 100 kHz to 50 MHz
Open Research DataThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...