displaying 1000 best results Help
Search results for: MINICHANNEL HEAT EXCHANGER
-
Experimental investigation of heat transfer enhancement in straight and U-bend double-pipe heat exchanger with wire insert
PublicationIn this paper, the possibility of heat transfer enhancement in the U-bend exchanger was presented. Experimental research has been carried out for four individual heat exchanger constructions i.e. plain tube in tube, turbulized tube in tube, plain U-bend and U-bend with turbulator. Also, heat transfer experiments for various boundary conditions were performed to obtain reference values. In case of U-bend exchanger with and without...
-
Performance analyses of helical coil heat exchangers. The effect of external coil surface modification on heat exchanger effectiveness
PublicationThe shell and coil heat exchangers are commonly used in heating, ventilation, nuclear industry, process plant, heat recovery and air conditioning systems. This type of recuperators benefits from simple construction, the low value of pressure drops and high heat transfer. In helical coil,centrifugal force is acting on the moving fluid due to the curvature of thetube results in the development. It has been long recognized that the...
-
The low temperature waste heat recovery in drying process of pine wood using micro-jet heat exchanger
PublicationThe article presents the influence of the drying medium temperature changes for the relative and absolute moisture content values during pine wood drying. The drying process was conducted at constant atmospheric pressure and with different drying medium (air) temperature levels, respectively: 40oC, 60oC, 80oC, 100oC, and 120oC. In order to develop a method that would enable low temperature drying of solid materials the experiments...
-
Thermal performance of a prototype plate heat exchanger with minichannels under boiling conditions
PublicationTo solve the problem and to meet the requirements of customers in the field of high heat fluxes transfer in compact units, a new design of plate heat exchanger with minichannels (minichannels PHE) was proposed. The aim was to construct a compact heat exchanger of high effectiveness for the purpose of household cogeneration ORC system. In this paper the experimental analysis of an assembled prototype of such compact heat exchanger...
-
A simple approach to heat exchanger sizing optimisation by means of entrophy generation minimisation
PublicationIn the paper an attempt is presented to find the method of optimization of microtube diameter with respect to optimal thermal-hydraulic conditions in the single-phase shell-and-tube heat exchangers. The approach is based on consideration of pumping power at the condition of maximum heat transfer by the heat exchanger tube system. In the optimization method the tube diameter is first specified and then appropriate calculations are...
-
Selection Of Optimal Working Fluid For Use With Hybrid Microchannel-Microjet Heat Exchanger
PublicationThe paper presents the investigation to find best suited working fluid for a microjet- microchannel cooling module. In which microjets are impinging into the microchannels and forming a liquid film on the impingement surface. This technology takes benefits from two very attractive heat removal techniques. When laminar jets are impinging on the surface have a very high kinetic energy at the stagnation point, also in microchannels...
-
EFFECT OF WORKING FLUID SELECTION ON THERMAL PERFORMANCE OF HEAT EXCHANGER FILLED BY THE POROUS MATERIAL
PublicationThermal management of electronics semiconductor technologies that are located i.e. in a novel marine power plants or computer server rooms become very important issue for designers of such systems. Motivation and need for research in development of novel cooling strategies for modern electronics is of paramount importance. Heat exchangers filled by the porous material are a novel research topic in current heat pipe science. The...
-
An experimental investigation on the effect of new continuous core-baffle geometry on the mixed convection heat transfer in shell and coil heat exchanger
PublicationIn the article, the authors presented the influence of continuous core-baffle geometry at mixed convection heat transfer in shell and coil heat exchanger. Experiments were carried out for a large power range, i.e. from 100W to 1200W and mass flow rates ranging from 0.01 kg/s to 0.025 kg/s. During the experiments, the mass flow rate of cooling water, the temperature of water at the inlet and outlet as well as the wall temperature...
-
A new construction of shell-and-tube heat exchanger with impinging jets and minichannels technologies for heat recovery from gases – experimental analysis
PublicationA dynamic development of technologies allowing waste heat utilization is observed in a correspondence with a pro-ecological approach of the zero waste idea. Such approach becomes the most demanding in the area of low-temperature was heat sources, especially gaseous media. Till now, they were usually not utilized due to unfavorable thermal conditions and high costs. Therefore, the zero waste approach directs research on techniques...
-
Numerical modeling of cross-flow heat exchanger for air-conditioning purposes in preliminary study.
PublicationPraca przedstawia wyniki obliczeń numerycznych krzyżowego płytowo-rurowego wymiennika ciepła przeznaczonego do celów klimatyzacyjnych w początkowym etapie jego projektowania.
-
Channel Blockage and Flow Maldistribution during Unsteady Flow in a Model Microchannel Plate heat Exchanger
PublicationThis paper describes the problem of channel blockage as a result of flow maldistribution between the channels of a model mini channel plate heat exchanger consisting of one pass on each leg. Each leg of the heat exchanger contains 51 parallel and rectangular minichannels of four hydraulic diameters namely 461 μm, 571 μm, 750 μm and 823 μm. In addition, a more complex geometry has been investigated where for the sake of breaking...
-
Monitoring Regenerative Heat Exchanger in Steam Power Plant by Making Use of the Recurrent Neural Network
PublicationArtificial Intelligence algorithms are being increasingly used in industrial applications. Their important function is to support operation of diagnostic systems. This paper pesents a new approach to the monitoring of a regenerative heat exchanger in a steam power plant, which is based on a specific use of the Recurrent Neural Network (RNN). The proposed approach was tested using real data. This approach can be easily adapted to...
-
Corrosion-erosion damage of heat exchanger tubes by desalted crude oil flowing at shell side
Publication -
Corrosion-erosion damage of heat exchanger tubes by desalted crude oil flowing at shell side.
PublicationRurki wymiennika zostały uszkodzone lokalnie przez odsoloną ropę naftową przepływającą pod ciśnieniem 2,6 MPa i w temperaturze 385-395K. Większość powierzchni rurek nie była uszkodzona i była pokryta osadem związków organicznych i nieorganicznych, zabezpieczającym przed uszkodzeniami. Badania wykluczyły możliwość występowania intensywnej korozji elektrochemicznej na powierzchniach rurek pozbawionych osadu. Przyczyną perforacji...
-
Thermal and economic investigation of straight and U-bend double tube heat exchanger with coiled wire turbulator
PublicationExperimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800–9000 – on the shell side, for a constant cold water temperature of 9 ◦C and hot water of 50 ◦C. The heat exchangers were made from copper tubes with...
-
Experimental investigation on straight and u-bend double tube heat exchanger with active and passive enhancement methods
PublicationAuthors in this work want to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. In the study, Wilson plot approach was applied in order to estimate heat transfer coefficients for all heat exchanger (HX) configurations. The study focuses on experimental values of heat transfer coefficient...
-
Selected aspects of two-phase flow studies using different visualization techniques in minichannels
PublicationThe subject of the study is to present the possibility of the use of visualization techniques in the researches on two-phase flows, carried out by the authors for many years. These works included as follows: heat transfer during the flow boiling, boiling crises and condensation in flow. The issue of the heat transfer intensification during the flow boiling through the channels of small diameters was analyzed. All this work focused...
-
CHARAKTERYSTYKA WYMIANY CIEPŁA I OPORÓW PRZEPŁYWU OMYWANIA MIKROSTRUGAMI ROZWINIĘTEJ POWIERZCHNI
PublicationW artykule przedstawiono eksperymentalne badania kompaktowego wymiennika ciepła z intensyfikacją przejmowania ciepła przy użyciu mikrostrug. Niniejszy artykuł przedstawia projekt i testy prototypu, wymiennika ciepła typu mikrostrugowego. Modułowa konstrukcja wymiennika umożliwia zmianę wymiarów geometrycznych, a także zmianę materiału przegrody wymiennika ciepła. Metoda graficzna Wilsona została z zastosowana w celu określenia...
-
Analytical and reliability data from the real-time simulator biogas plant
Open Research DataThe dataset represents the results of biogas plant simulation. The described plant is an agricultural biogas system, which can produce electrical energy with power estimated up to 1070 kW and heat energy that can reach 1200 kW simultaneously.
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...