Novel structure and size-reduction-oriented design of microstrip compact rat-race coupler
PublicationIn this paper, a novel structure of a miniaturized microstrip rat-race coupler has been proposed. Surrogate-based optimization procedures are applied to explicitly reduce the coupler size while maintaining equal power split at the operating frequency of 1 GHz and sufficient bandwidth for return loss and isolation characteristics. The optimization is performed using the objective function with four penalty components. The footprint...
-
Uncertainty Quantification of Additive Manufacturing Post-Fabrication Tuning of Resonator-Based Microwave Sensors
PublicationReconfigurability, especially in terms of the ability of adjusting the operating frequency, has become an important prerequisite in the design of modern microwave components and systems. It is also pertinent to microwave sensors developed for a variety of applications such as characterization of material properties of solids or liquids. This paper discusses uncertainty quantification of additive-manufacturing-based post-fabrication...
-
Optimization-Based Robustness Enhancement of Compact Microwave Component Designs with Response Feature Regression Surrogates
PublicationThe ability to evaluate the effects of fabrication tolerances and other types of uncertainties is a critical part of microwave design process. Improving the immunity of the device to parameter deviations is equally important, especially when the performance specifications are stringent and can barely be met even assuming a perfect manufacturing process. In the case of modern miniaturized microwave components of complex topologies,...
-
Non-isolated resonant quasi-Z-source network DC–DC converter
PublicationA novel non-isolated resonant quasi-impedance (quasi-Z)-source network DC–DC converter is proposed. The resonant impedance source network is derived from the quasi-Z-source network by including the autotransformer-based resonant cell instead of the second inductor of the quasi-Z-network. The leakage inductance of the autotransformer and two resonant capacitors connected in series with the autotransformer windings constitute a high-frequency...
-
New concept and analysis of the multicell piezoelectric motor
PublicationThis work presents the design, modeling and tests of the prototype multicell piezoelectric motor (MPM). A new concept of the electromechanical structure of the considered prototype is based on three rotating-mode actuators. The electromechanical structure of each actuator has been considered as an independent one - referred to as a ”single cell” (single actuator). Combined three resonant actuators generate three traveling waves...
-
Chosen Analysis Results Of The Prototype Multicell Piezoelectric Motor
PublicationThis paper presents the design, modeling and tests of the prototype multicell piezoelectric motor (MPM). A new concept of the electromechanical structure of the considered prototype is based on three rotating-mode actuators. The electromechanical structure of each actuator has been considered as an independent one - referred to as a “single cell” (single actuator). Combined three resonant actuators generate three traveling waves...
-
Koncepcja i modelowanie wysokoobrotowego napędu elektrycznego turbosprężarki. Zastosowanie w ogniwach paliwowych pojazdów samochodowych
PublicationAbstract: Electrical vehicles powered by hydrogen fuel cells become a potential alternative to conventional vehicles. The polymer electrolyte membrane (PEM) are typical fuel cells used in fuel cell vehicle (FCV). The global efficiency of a PEM fuel cell stack is greatly impacted by the use of a motorized compressor for the air supply system. The motor-compressor set-up may consume up to 19 % of the energy supplied by the PEM fuel...
-
Building a Nest by an Automaton
PublicationA robot modeled as a deterministic finite automaton has to build a structure from material available to it. The robot navigates in the infinite oriented grid $Z x Z$. Some cells of the grid are full (contain a brick) and others are empty. The subgraph of the grid induced by full cells, called the {\em field}, is initially connected. The (Manhattan) distance between the farthest cells of the field is called its {\em span}. The robot...
-
Experimental data of galvanic electric cells measurements
Open Research DataInternal temperature of an electric cell can be measured and monitored using microsphere-based fiber-optic sensors with thin ALD ZnO coating. Their compact size will allow to integrate them easily and effectively within the electric cells. Utilization of presented sensors allows to detect, in real time, damages to the structure of the sensor head that...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Design and Experiments of a Piezoelectric Motor Using Three Rotating Mode Actuators
PublicationThis paper represents a numerical and experimental investigation of the multicell piezoelectric motor. The proposed design consists of three individual cells that are integrated into the stator, double rotor, and a preload system combined into a symmetrical structure of the motor. Each of the cells is characterized by a traveling wave and rotating mode motor. A finite element numerical analysis is carried out to obtain optimal...
-
Design Evolution of the Ultrasonic Piezoelectric Motor Using Three Rotating Mode Actuators
PublicationThe development process and experimental investigation of the multicell piezoelectric motor is presented in this paper. The proposed design consists of three individual cells integrated into the stator, double rotor, and a preload system. Those elements are combined into a symmetrical structure of the motor. The two new prototypes have been designed, simulated and tested. Finite element numerical analysis is carried out to obtain...
-
Compressive strength and density of cement pastes containing iron oxide (Fe3O4) nanoparticles (nanomagnetite)
Open Research Data*.ODS - open-data source spreadsheet - Dataset presenting:
-
Characteristics of LaCo 0.4 Ni 0.6-x Cu x O 3-δ ceramics as a cathode material for intermediate-temperature solid oxide fuel cells
PublicationIn this study, the effects of Cu-ion substitution on the densification, microstructure, and physical properties of LaCo0.4Ni0.6-xCuxO3-δ ceramics were investigated. The results indicate that doping with Cu ions not only enhances the densification but also promotes the grain growth of LaCo0.4Ni0.6-xCuxO3-δ ceramics. The Cu substitution at x ≤ 0.2 can suppress the formation of La4Ni3O10, while the excess Cu triggers the formation...
-
Rheological and compressive strength (ultrasonic pulse method) properties of cement pastes containing iron oxide (Fe3O4) nanoparticles
Open Research DataRheological data of cement pastes containing different replacement levels of cement with iron oxide nanoparticles deterimined using MCR 301 (Anton Paar) stress-imposed rheometer, equipped with calibrated helicoidal geometry
-
Rapid Design of 3D Reflectarray Antennas by Inverse Surrogate Modeling and Regularization
PublicationReflectarrays (RAs) exhibit important advantages over conventional antenna arrays, especially in terms of realizing pencil-beam patterns without the employment of the feeding networks. Unfortunately, microstrip RA implementations feature narrow bandwidths, and are severely affected by losses. A considerably improved performance can be achieved for RAs involving grounded dielectric layers, which are also easy to manufacture using...
-
Novel Versatile Topologies and Design Optimization of Wide-Bandstop Frequency Selective Surfaces for X-Band, Ku-Band and Millimeter-Wave Applications
PublicationNovel designs of frequency selective surface (FSS) are presented for wideband applications in X, Ku and mmWave (millimeter Wave) bands. Two identical metallic layers of FSS are imprinted on both sides of the RO4003 substrate. The geometry parameters are optimized to maximize the bandstop at the specified in-band maximum transmission level of –10 dB; satisfaction of the latter condition is enforced through appropriate formulation...
-
Circularly Polarized Metalens Antenna Design for 5G NR Sub-6 GHz Communication Systems
Publication5G NR (new radio) FR1 range refers to as Sub-6GHz band (410MHz to 7125MHz and 3.4GHz to 6GHz). In this paper, the frequency range of interest is from 3.4 to 6GHz, as many cellular companies are focusing on this Sub-6GHz band. A wideband circularly polarized (CP) antenna radiator is designed with diamond shape patches, fed by a microstrip line at the bottom through a rectangular shape wide slot on a ground plane. The proposed CP...
-
9-Cyano-10-methylacridinium hydrogen dinitrate
PublicationThe title compound, C15H11N2+·HN2O6−, crystallizes in the monoclinic space group C2/c with four molecules in the unit cell. The planar 9-cyano-10-methylacridinium cations lie on crystallographic twofold axes and are arranged in layers, almost perpendicular to the ac plane, in such a way that neighbouring molecules are positioned in a `head-to-tail' manner. These cations and the hydrogen dinitrate anions are linked through C—H⋯O...
-
Designing a High-sensitivity Microscale Triple-band Biosensor based on Terahertz MTMs to provide a perfect absorber for Non-Melanoma Skin Cancer diagnostic
PublicationNon-melanoma skin cancer (NMSC) is among the most prevalent forms of cancer originating in the top layer of the skin, with basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) being its primary categories. While both types are highly treatable, the success of treatment hinges on early diagnosis. Early-stage NMSC detection can be achieved through clinical examination, typically involving visual inspection. An alternative,...