Filters
total: 11
Search results for: kurtosis
-
Peculiarities of measurement uncertainty evaluation at calibrating a ring gauge
PublicationExample S13 from EA-4/02 M:2013 “Calibration of a ring gauge with a nominal diameter of 90 mm” is analyzed. The report uses the kurtosis method and the law of propagation of expanded uncertainty developed by the authors to the expanded uncertainty evaluation. It is shown that the introduction of a coaxiality correction for the ring gauge and the measuring axis of the comparator leads to the need to estimate its standard measurement...
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
On the Handling of Outliers in the GNSS Time Series by Means of the Noise and Probability Analysis
PublicationThe data pre-analysis plays a significant role in the noise determination. The most important issue is to find an optimum criterion for outliers removal, since their existence can affect any further analysis. The noises in the GNSS time series are characterized by spectral index and amplitudes that can be determined with a few different methods. In this research, the Maximum Likelihood Estimation (MLE) was used. The noise amplitudes...
-
Outlier detection method by using deep neural networks
PublicationDetecting outliers in the data set is quite important for building effective predictive models. Consistent prediction can not be made through models created with data sets containing outliers, or robust models can not be created. In such cases, it may be possible to exclude observations that are determined to be outlier from the data set, or to assign less weight to these points of observation than to other points of observation....
-
Optimal placement of IMU sensor for the detection of children activity
PublicationIn this paper an investigation to determine the optimal placement of IMU sensors for the purpose of children characteristic activity detection is presented. The article compares four different placement of two IMU sensors on human body. Ten healthy volunteers participated within the study. Data were collected firstly from two wireless 9-axial IMU sensors placed at the left and right wrists, then sensors were placed at lower back...
-
A Simplified Method of Trend Removal to Determine Noise Observed During a Supercapacitor’s Discharging
PublicationIn this paper, new method of trend removal is proposed. This is a simplified method based on Empirical Mode Decomposition (EMD). The method was applied for voltage time series observed during supercapacitor discharging process. It assured the determination of an additive noise component after subtracting the identified trend component. We analyzed voltage time series observed between the terminals of the supercapacitor when discharged...
-
Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer
PublicationThe discords concerning the measurement uncertainty evaluation in the Guide to the Expressing of Uncertainty in Measurement (GUM) and its Supplement 1 are considered. To overcome these discords, the authors of the paper propose to use the kurtosis method and the law of the propagation of the expanded uncertainty. Using the example of the goniometer calibration, the features of accounting for the distribution laws of input quantities...
-
Cyclic deformation and fracture behaviour of additive manufactured maraging steel under variable-amplitude loading
PublicationThe cyclic deformation and fracture behaviour of 18Ni300 maraging steel produced by laser beam powder bed fusion is studied under variable-amplitude loading. The tests were conducted under fully-reversed strain-controlled conditions with a loading sequence comprising three ascending cycles and three descending cycles repeated sequentially until failure. After the tests, fracture surfaces were examined using height and volume surface...
-
Could thermal imaging supplement surface electromyography measurements for skeletal muscles?
PublicationAbstract—(1) Background: The aim of this study is to present the results of experiments in which surface electromyography (sEMG) and thermal imaging were used to assess muscle activation during gait and to verify the hypothesis that there is a relationship in the case of low fatigue level between sEMG measured muscle activation, assessed in the frequency domain, and thermal factors calculated as minimum, maximum, kurtosis, mean,...
-
Results of research on the SME sector in the context of applying tax reliefs
Open Research DataThis dataset presents the quantitative results of the survey conducted in the period June 2019 - April 2020. In total, 274 completed survey questionnaires were obtained.
-
Underground Water Level Prediction in Remote Sensing Images Using Improved Hydro Index Value with Ensemble Classifier
PublicationThe economic sustainability of aquifers across the world relies on accurate and rapid estimates of groundwater storage changes, but this becomes difficult due to the absence of insitu groundwater surveys in most areas. By closing the water balance, hydrologic remote sensing measures offer a possible method for quantifying changes in groundwater storage. However, it is uncertain to what extent remote sensing data can provide an...