Search results for: INTERFEROMETERIA POLARYZACYJNA
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 10 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 10 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Sposób poprawy własności dynamicznych czujników konduktometrycznych.
PublicationW artykule przeanalizowano wpływ mechanizmu transportu migracyjnego jonów na własności dynamiczne czujników konduktometrycznych. Pokazano, że czujniki te są przetwornikami pierwszego rzędu i ich właściwości dynamiczne determinowane są przez ich budowę. Zaproponowano modyfikację konstrukcji tych czujników poprzez wprowadzenie dodatkowej elektrody polaryzacyjnej. Elektroda ta zwiększa gradient potencjału pola elektrycznego na powierzchni...
-
Direct measurement of nonlinear properties of bipartite quantum states
PublicationNieliniowe własności stanów kwantowych, takie jak entropia, splątania, określają ilość ważnych fizycznych źródeł i są często używane w informatyce kwantowej. Na ogół są one obliczane z pełnego opisu stanu kwantowego, pomimo tego, że zależą od niewielkiej ilości parametrów opisujących dany stan. Wyciągamy nielokalną i nieliniową wielkość, mianowicie entropię Renyi, z lokalnych pomiarów dwóch par fotonów splątanych polaryzacyjnie.
-
Badania naprężeń własnych laserowo przetapianej stali X20Cr13 pod wpływem kawitacji.
PublicationPraca prezentuje badania wpływu obciążeń kawitacyjnych przetapianej laserowo stali X20Cr13 na wielkość naprężeń własnych. Do wyznaczania wielkości naprężeń własnych zastosowano metodę zautomatyzowanej interferometrii siatkowej.
-
Electron-beam irradiation in TEM of hard-segment homopolymers and polyurethanes with different hard-segment content.
PublicationZbadano odporność na niszczenie radiacyjne w transmisyjnym mikroskopie elektronowym homopolimeru segmentów sztywnych i poliuretanów z różną zawartością segmentów sztywnych. Dokonano rejestracji morfologii tych polimerów w TEM w trakcie obserwacji w jasnym polu oraz selektywnej dyfrakcji elektronowej. Analizowano tkże te polimery w mikroskopie polaryzacyjnym przed i po obserwacjach w TEM. Potwierdzono doniesienia literatutowe o...
-
Nitrogen-Doped Diamond Film for Optical Investigation of Hemoglobin Concentration
PublicationIn this work we present the fabrication and characterization of a diamond film which can be utilized in the construction of optical sensors for the investigation of biological samples. We produced a nitrogen-doped diamond (NDD) film using a microwave plasma enhanced chemical vapor deposition (MWPECVD) system. The NDD film was investigated with the use of scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman...
-
Optical low-coherence interferometry for selected technical applications
PublicationW artykule przedstawiono teoretyczne podstawy optycznej interferometrii niskokoherentnej i przedyskutowano jej unikatowe właściwości. Opisano w nim opracowany przez autorów system OCT przeznaczony do badań strukturalnych materiałów technicznych. Badania te obejmują także zmiany stanu polaryzacji promieniowania rozproszonego w badanym obiekcie. W artykule zawarto wyniki badań wybranych materiałów silnie rozpraszających promieniowanie...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublicationIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
Impedancyjne monitorowanie szybkości korozji w układach wodnych z zastosowaniem inhibitorów korozji
PublicationNiniejsza praca jest poświęcona opracowaniu metodyki pomiarowej pozwalającej na wyznaczanie szybkości korozji za pomocą metody galwanodynamicznej elektrochemicznej spektroskopii impedancyjnej (GDEIS). Zaproponowana metoda pozwala na wykonywanie badań korozyjnych w których klasyczne metody pomiarowe (polaryzacja liniowa, metoda EIS, polaryzacja Tafela) charakteryzują się otrzymywaniem wyników ze znaczną dozą niepewności. W przypadku...
-
Electrochemical methods for corrosion rate determination under cathodic polarisation conditions - a review. Part II - AC methods
PublicationPrzedstawiono krytyczny przegląd prac dotyczących wykorzystania metod elektrochemicznych zmiennoprądowych do wyznaczania prądu korozyjnego metali polaryzowanych katodowo. Przedyskutowano stosowanie klasycznej liniowej spektroskopii impedancyjnej (EIS) z użyciem sygnałów pobudzających niskoamplitudowych, a następnie techniki zmiennoprądowe bazujące na sygnałach wysokoamplitudowych, a więc w zakresie nieliniowej charakterystyki polaryzacyjnej...
-
Corrosion monitoring of selected metals in artificial seawater by harmonic synthesis method
PublicationPrzedstawiono podstawy teoretyczne nowej metody elektrochemicznej nazwanej metodą syntezy harmonicznej (SH). Metoda jest oparta na pomiarach pierwszych trzech składowych harmonicznych prądu generowanego przez korodującą elektrodę po pobudzeniu sinusoidalnym sygnałem napięciowym bardzo niskiej częstotliwości. Na tej podstawie rekonstruowana jest dyskretna quasi-stacjonarna charakterystyka polaryzacyjna elektrody. Jej analiza numeryczna...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublicationThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublicationIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Potential and strain rate impact on the electrochemical properties of 304L stainless steel under tensile stresses.
PublicationPraca skupia się na badaniach aspektu elektrochemicznego i mechanicznego pękania warstwy pasywnej obecnej na stali 304L. Przedstawione zostały wyniki chwilowych zmian impedancji oraz zmiany parametrów elektrochemicznych warstwy pasywnej podczas testów rozciągania przy różnych poziomach polaryzacji anodowej oraz szybkości rozciągania. Na ich podstawie można stwierdzić, że zarówno czynnik elektrochemiczny, jak i mechaniczny wpływają...
-
Methods of electrochemical noise analysis for investigation of corrosion processes
PublicationKorozja elektrochemiczna może być oceniana za pomocą przpływu ładunków między korodującym metalem a elektrolitem. Zwykle, przpływ ładunku obserwuje się w układzie trzech elektrod jako fluktuacje prądu i napięcia (szumy elektrochemiczne). Na podstawie analizy szumów elektrochemicznych można wykrywać różne rodzaje korozji. Korozja jednorodna jest oceniana za pomocą wartości rezystancji polaryzacyjnej występującej między metalem a...
-
Cross section calculations for electron impact ionization and elastic scattering from cisplatin
PublicationCałkowity przekrój czynny na jednokrotną jonizację cisplatyny (H6N2Cl2Pt) w zderzeniach z elektronami został obliczony przy wykorzystaniu modelu BEB (binary-encounter-Bethe) dla energii zderzenia od progu na jonizację do 5 keV. W celu uzyskania danych niezbędnych w modelu BEB, geometryczna i elektronowa struktura cisplatyny została przebadana metodami chemii kwantowej. Obliczono również przekrój czynny na sprężyste rozproszenie...
-
Badanie i analiza właściwości kanałów radiowych w sieciach WBAN (część 2)
PublicationW tej części artykułu przeprowadzono analizę zaników wolnozmiennych i szybkozmiennych w sieciach WBAN typu off-body z przestrzennym odbiorem zbiorczym oraz analizę stopnia skorelowania odbieranych sygnałów. Zaprezentowano model kanału radiowego dla wąskopasmowych i szerokopasmowych sieci WBAN typu off-body, pracujących w środowisku promu pasażerskiego. Przeprowadzono analizę porównawczą zaników wolnozmiennych i szybkozmiennych...
-
Metody matematyczne syntezowania źródeł optycznych do interferometrów niskokoherentnych dla zastosowa biomedycznych
PublicationW pracy przedstawiono mozliwosci wykorzystania metod matematycznych w układach interferometrii niskokoherentnej do zastosowan biomedycznych. Metody takie sa wykorzystywane na kazdym z etapów realizacji układów: projektowania poszczególnych elementów, obróbki danych pomiarowych oraz w trakcie walidacji techniki pomiarowej. W pracy przedstawiono mozliwosci optymalizacji parametrów metrologicznych interferometrów niskokoherentnych...
-
Optical properties of thin TiO2 film deposited on the fiber optic sensor head
PublicationThe presented study was focused on investigation of the titanium dioxide (TiO2) thin film deposited on the fiber tip. The intention of this investigation was using TiO2 film in the construction of the optical fiber sensor head. In the demonstrated construction TiO2 thin layer was deposited on the tip of a commonly used telecommunication single mode optical fiber (SMF-28) by means of the Atomic Layer Deposition (ALD). Thickness...
-
Effect of temperature change on refractive index of an egg white and yolk: a preliminary study
PublicationIn this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...
-
1D portable optical coherence tomography system
Publication—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...