Search results for: wcv
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.80, b=0.25) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.7, b=0.32) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.1, b=0.14) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.7, b=0.32) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.1, b=0.14) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Joanna Rymaszewska prof. dr hab. n. med.
PeopleCV Joanna Rymaszewska Wroclaw University of Science and Technology, Wroclaw, Poland +48 601 98 26 24, joanna.rymaszewska@pwr.edu.pl orcid.org/0000-0001-8985-3592 2023 → Professor of Wroclaw University of Science and Technology (WUST), Poland 2011 → 2023 Professor of Wroclaw Medical University (WMU), PL 2016 → 2022 Head of the Department of Psychiatry, Wroclaw Medical University 2016 → 2022 Head of the Clinic of Psychiatry,...
-
Local impedance spectroscopy of membranes
PublicationCelem niniejszej publikacji jest zaprezentowanie zastosowania techniki Lokalnej Elektrochemicznej Spektroskopii Impedancyjnej (LEIS) do uzyskania lokalnej charakterystyki membran. Membranę wykonaną z polichlorku winylu (PCV), plastyfikowaną sebacynianem bis(2etyloheksylu) i domieszkowaną boranem tetradodecyloamoniowym zbadano pod kątem równomiernego rozkładu przewodnictwa na powierzchni badanej próbki. Lokalne pomiary impedancyjne,...
-
GIS for processing multidimensional marine data in SAAS model
PublicationGeographic Information Systems (GIS) have always been a useful tool for visualization and processing of geospatial data. However, their capabilities of analysis non-standard information such as hydroacoustic soundings has thus far been very limited. This paper proposes a general-purpose GIS which uses techniques such as OLAP, WCS and WCPS for processing of multidimensional spatio-temporal data. The versatility of the GIS is exemplified...
-
Hepatocellular carcinoma, NOS - Female, 72 - Tissue image [9080730005569241]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Korekcja wymiarowa nagniataniem na tokarkach CNC
PublicationW rozdziale monografii poruszono problematykę nagniatania ślizgowego z wykorzystaniem kulek ceramicznych z węgliku wolframu WC. Kulki ceramiczne WC jako element nagniatający zastosowano podczas obróbki na tokarce CNC. Uzyskanie zadawalającej jakościowo powierzchni na stali 40H wymagało spełnienia szczegółowych warunków technologicznych. W rozdziale omówiono problemy technologiczne związane z ustawieniem narzędzia do nagniatania...
-
Fizyka III (WCH) - ćwiczenia
e-Learning CoursesĆwiczenia dla studentów kierunku Inżynieria Materiałowa z przedmiotu Fizyka III - grupa WCH
-
Novel sugar-based nickel-tungsten carbide catalysts for dry reforming of hydrocarbons
PublicationThe search for new materials for dry reforming of hydrocarbons with high activity, stability, and ease of synthesis is still one of the main directions of research in the field of heterogeneous catalysis. Traditional methods of carbide synthesis require the use of combustible gases of petrochemical origin. The search for new catalysts based on renewable and safe carbon sources is highly demanded. Therefore, we report WC and Ni-WC...
-
Determination of Antioxidant Activity of Vitamin C by Voltammetric Methods
PublicationVoltammetric methods—cyclic (CV) and differential pulse voltammetry (DPV) are considered the most appropriate way to evaluate antioxidant activity of redox active compounds. They provide information about both mechanism and kinetics of electrochemical oxidation of antioxidants as well as their physical and chemical properties such as the redox potential or the number of electrons transferred. These methods are helpful for understanding...
-
Hepatocellular carcinoma, NOS - Female, 72 - Tissue image [9080730005568061]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatocellular carcinoma, NOS - Female, 72 - Tissue image [9080730005566341]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adsorptive Removal of Aqueous Phase Crystal Violet Dye by Low-Cost Activated Carbon Obtained from Date Palm (L.) Dead Leaflets
PublicationUp to now, water pollution is still one of the important issues and challenges worldwide, due to its environmental, economic and human life impacts. It is also remains a challenge to environment scientists and technologists. Nowadays, the textile dyeing industry is considered one of the largest water consuming industries and produces large volumes of colored wastewater in its dyeing and finishing process. In this study, date palm...
-
Relation of the polymorphism of cyp51A sequence and the susceptibility of Aspergillus fumigatus isolates to triazoles determined by commercial gradient test (Etest) and by reference methods
PublicationThe aim of this study was to evaluate the accuracy of commercial gradient test (Etest) in the detection of triazole resistant Aspergillus fumigatus isolates using reference microdilution methods and the analysis of sequences of the cyp 51A gene. The study was performed on twenty clinical isolates which were identified as Aspergillus fumigatus based on the DNA sequences of the ITS1-2 fragment of ribosomal DNA and the β-tubulin gene,...
-
FIZYKA CIAŁA STAŁEGO (PG_00049429)
e-Learning CoursesKierunek: Korozja (WCh), II stopnia, stacjonarne, 2021/2022 - letni (obecnie sem. 1)
-
Determination of total mercury in fish and cormorant using cold vapour atomic absorption spectrometry
PublicationW pracy opisano technikę CV-AAS do oznaczania zawartości rtęci całkowitej w tkankach ryb i kormorana. Przedstawiono proces walidacji zastosowanej procedury analitycznej, w ramach którego wyznaczono takie parametry walidacyjne jak:- selektywność,- liniowość (r>0,993),- zakres pomiarowy (0,29-100 ng),- poprawność (odzysk 98%),- powtarzalność (CV <10%).Wartość rozszerzonej niepewności <13%.Przedstawiono wyniki pomiarów dla 8 gatunków...
-
Damian Rosiak dr inż.
PeopleEducation 2010–2014: Gdansk University of Technology, Chemical Faculty (Eng.) field of study: biotechnology specialty: drug biotechnology 2014–2015: Gdansk University of Technology, Chemical Faculty (M.Sc.) field of study: biotechnology specialty: drug biotechnology 2015–2020: Gdansk University of Technology, Department of Inorganic Chemistry (Ph.D.) discipline: chemical sciences specialty: inorganic chemistry Scientific...
-
A new phosphonium calix[4]arene for selective anion recognition: synthesis and studies in solution and in ion selective electrodes
PublicationZaprezentowana została synteza i charakteryzacja tetra (trifenylofosfoniowego) p-tert-butylkaliks[4]arenu 2. Oddziaływania z anionami były badane z użyciem (1)H oraz (31)P NMR i spektrofotometrii absorpcyjnej UV. Badania wykazały oddziaływania z anionami: CLO4-, I-, oraz SCN-. Selektywność jonoforu 2 badano również w membranowych elektrodach jonoselektywnych (ISE) PCV/o-NPOE. Elektroda zawierająca związek 2 generuje odpowiedź potencjometryczną...
-
Filozofia - Bio - 21/22
e-Learning Coursesnazwa przedmiotu: Filozofia - tryb studiów - stacjonarne - stopień studiów - I stopnia - inżynierskie - kierunek studiów: Biotechnologia(WCh)
-
Filozofia - Bio - 22/23
e-Learning Coursesnazwa przedmiotu: Filozofia - tryb studiów - stacjonarne - stopień studiów - I stopnia - inżynierskie - kierunek studiów: Biotechnologia(WCh)
-
Wear Resistance Enhancement of Al6061 Alloy Surface Layer by Laser Dispersed Carbide Powders
PublicationIn this paper, results of the experimental study on improving wear resistance in sliding friction of Al-based alloy are presented. The technique used involves the formation of a metal matrix composite (MMC) in the alloy surface layer by laser dispersion of carbide powders such as WC, TiC and SiC. For WC and TiC MMC surface coatings fabricated under conditions typical for most of the technologically relevant solid-state lasers (wavelength...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.7, b=0.32) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.1, b=0.14) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.8, b=0.25) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.5, b=0.37) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.4, b=0.26) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.0, b=0.11) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=2.80, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=2.80, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=2.00, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...