Publications
Filters
total: 787
Catalog Publications
Year 2018
-
Using Wearable Electronics to Estimate Usefulness of Heart Rate Variability for Bathing Person Identif Cation
PublicationIn this paper the possibility of person identification based on biosignal is investigated. The work focus on the analysis of the changes in intervals between successive R-waves of electrocardiogram (ECG) recorded by wearable electronics in form of a necklaces. The main idea behind this project is to find efficient tool which may prevent sudden consciousness loss episodes or even sudden death episodes related to rapid temperature...
-
Water chemistry of tundra lakes in the periglacial zone of the Bellsund Fiord (Svalbard) in the summer of 2013
PublicationClimate changes observed in the Arctic (e.g. permafrost degradation, glacier retreat) may have significant influence on sensitive polar wetlands. The main objectives of this paper are defining chemical features of water within six small arctic lakes located in Bellsund (Svalbard) in the area of continuous permafrost occurrence. The unique environmental conditions of the study area offer an opportunity to observe phenomena influencing...
-
Wavelet Transform Analysis of Temperature Modulated Gas Sensor Response
PublicationThe aim of the study was to evaluate whether it is possible to extract the information about the gas concentration despite the influence of humidity. Commercial semiconductor sensor response was examined under the application of a periodic temperature change. The data was collected using measurement protocol for different concentrations of ammonia at specified levels of relative humidity. In this work we focused on the evaluation...
Year 2006
-
Validity of MRI brain perfusion imaging method
PublicationW artykule zaprezentowano zbiór analiz dotyczących walidacji metody DSC-MRI. Zbadano wpływ rozmycia, opóźnienia, niskiego SNR bolusa oraz innych możliwych źródeł zakłócających wartość parametru perfuzji. Różne metody uzyskiwania parametrów perfuzji zostały zaprezentowane i porównane.
-
Validity of MRI brain perfusion imaging method
PublicationW artykule zaprezentowano zbiór analiz dotyczących walidacji metody DSC-MRI. Zbadano wpływ rozmycia, opóźnienia, niskiego SNR bolusa oraz innych możliwych źródeł zakłócających wartość parametru perfuzji. Różne metody uzyskiwania parametrów perfuzji zostały zaprezentowane i porównane.
Year 2017
-
Virtual designs and reconstructions of amber works: Amber craftsman simulator
PublicationThis paper presents the concept of visualization of amber works in a virtual reality cave. It describes problems encountered during the acquisition, modeling and rendering of geometrical objects distinguished by heterogeneous transparency.
Year 2015
-
Visual Attention Distribution Based Assessment of User's Skill in Electronic Medical Record Navigation
PublicationCurrently, the most precise way of reflecting the skills level is an expert’s subjective assessment. In this paper we investigate the possibility of the use of eye tracking data for scalar quantitative and objective assessment of medical staff competency in EMR system navigation. According to the experiment conducted by Yarbus the observation process of particular features is associated with thinking. Moreover, eye tracking is...
Year 2013
-
VOLTAMMETRIC DETERMINATION OF DEOXYRIBONUCLEIC ACID PRESENCE ON A CARBON ELECTRODE
PublicationThis paper presents a voltammetry as a useful method to analyse DNA from different species. This electrochemical method is well know and used in different analyses. The influence of an area of working electrode and the capacity component, is shown at equals and the measurement. In voltammetry DNA measurement the capacity component is very important and must be taken into consideration. All mathematical analyses were verify at laboratory.
-
Wpływ konfiguracji elektrod pomiarowych oraz parametrów pomiaru na EDR
PublicationW pracy przebadano wplyw wybranych konfiguracji elektrod na jakość uzyskiwanego sygnału EDR. Analizie poddane zostały również częstotliwość próbkowania sygnału EKG i rozdzielczość przetwornika AC/DC. Optymalną konfiguracją elektrod jest odprowadzenie kończynowe pierwsze. Minimalne parametry układu pomiarowego do uzyskania wysokiej jakości sygnału EDR, to częstotliwość probkowania 2,5kHz oraz 14-bitowy przetwornik AC-DC.
-
Wpływ metodyki obliczania mózgowej objętości krwi na wiarygodność diagnozy udaru niedokrwiennego w badaniach DSC-MRI
PublicationNiedokrwienny udar mózgu jest jednym z najczęściej spotykanych oraz najlepiej udokumentowanych incydentów mózgowo-naczyniowych (Dani et al., Ann Neurol 2011, 70(3), 384-401), a obrazowanie mózgu metodą DSC-MRI (ang. Dynamic Susceptibility Contrast - Magnetic Resonance Imaging) wskazuje się jako umożliwiające m.in. diagnozę niedokrwionej tkanki, prognozę jej dalszych losów, oraz rozróżnienie niedokrwienia odwracalnego od nieodwracalnego...
Year 2016
-
Warstwy funkcjonalne tlenkowych ogniw paliwowych
PublicationIn this paper, results describing current research on solid oxide fuel cells conducted at Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics are presented. The results are related to three kinds of functional layers: a thin cathode layer between the porous cathode layer and the electrolyte to improve the cathode performance, a buffer layer between the electrolyte and the cathode to slow...
Year 2011
-
Wirtualny gabinet medyczny
PublicationW pracy zaprezentowane możliwości opracowanego serwisu Wirtualny Gabinet Medyczny umożliwiającego dokonywanie konsultacji lekarskich bez konieczności opuszczania domu.
-
Właściwości dynamiczne elektrody woltamperometrycznej w dziedzinie częstotliwości i koncepcja metody ich wyznaczenia
PublicationW artykule przeanalizowano zasadę pracy elektrody woltamperometrycznej. Z przeprowadznej analizy wynika, że elektroda woltamperometryczna w przypadku oznaczeń małych stężeń jest przetwornikiem I rzędu. Jej właściwości metrologiczne określa czułość, stała czasowa i częstotliwość graniczna. W artykule zaproponowano metodę pomiaru parametrów dynamicznych na podstawie pomiaru prądu granicznego reakcji elektrochemicznj przebiegajacej...
Year 2003
-
Właściwości funkcjonału celu D-optymalnego schematu próbkowania dla modeli kompartmentowych.
PublicationStworzony został program pozwalający na wizualizację rozkładu funkcji celu dla 1-kompartmentowych, 2-kompartmentowych i 3-kompartmentowych modeli, których odpowiedź ma postać sumy eksponent. W pracy przedstawiono przykładowe rozkłady funkcji celu i algorytm poszukiwania jej ekstremów.
Year 2012
-
Właściwości metrologiczne elektrod woltamperometrycznych w dziedzinie częstotliwości i metoda ich wyznaczania
PublicationW pracy przeanalizowano właściwości metrologiczne elektrod woltamperometrycznych w dziedzinie częstotliwości. Wykazano, że w przypadku małych stężeń oznaczanych jonów, elektrody te mogą być traktowane jak przetworniki pomiarowe I rzędu. Ich właściwości metrologiczne charakteryzowane są przez czułość i częstotliwość graniczną. Przeanalizowano zastosowanie metody chronoamperometrycznej do wyznaczania wartości częstotliwości granicznej...
-
Właściwości strukturalne i katalityczne domieszkowanych związków typu SrTi(1-x)Fe(x)O3
PublicationPublikacja naukowa opisująca wytwarzanie i badanie właściwości strukturalnych i katalitycznych domieszkowanego itrem i żelazem tytanianu strontu.
-
WPŁYW TECHNIKI MONITORINGU CIŚNIENIA KRWI NA KRĄŻENIE W DŁONI CZŁOWIEKA
PublicationPrzeprowadzono badania dotyczące wpływu pracy profesjonalnego monitora ciśnienia krwi CNAP 500 Monitor na krąŜenie w badanej dłoni. Zmierzono czas od zespołu QRS sygnału EKG do momentu pojawienia się minimum i maksimum sygnału fali tętna na nadgarstku oraz palcu pomierzonych z zastosowaniem czujników optycznych. Dodatkowo przeprowadzono oszacowanie teoretyczne moŜliwych zmian oraz analizę impedancyjną...
Year 2014
-
Wpływ kształtu elektrody woltamperometrycznej na jej właściwości metrologiczne w dziedzinie czasu
PublicationW artykule omówiono właściwości metrologiczne elektrod woltamperometrycznych. Wykazano, że w przypadku oznaczania małych wartości stężeń jonów metali, elektrody te zachowują się tak jak przetworniki pomiarowe I rzędu. Ich właściwości metrologiczne opisuje czułość i stała czasowa. Wartości tych wielkości są uzależnione od mechanizmu transportu jonów do/od powierzchni elektrod oraz od ich kształtu. Wykonano symulacje wpływu kształtu...
Year 2008
-
Wpływ wyboru elementu strukturalnego użytego w przetwarzaniu morfologicznym na skuteczność nowej metody usuwania tła z sekwencji MRI
PublicationZaprezentowano nową metodę usuwania zaszumionego tła z sekwencji skanów MRI. Na każdy skan składają się dwa obszary: przekrój mózgu i tło, oba zawierające szum. Tło powinno być odseparowane i wykluczone z dalszej analizy. Cel ten został osiągnięty dzięki zastosowaniu opisanego algorytmu, aplikującego podstawowe operacje morfologiczne: dylację, erozję, otwarcie i zamknięcie do uprzednio zbinaryzowanych zbiorów MRI. Pokazano rezultaty...
Year 2007
-
Wspomaganie diagnostyki układu oddechowego przez modelowanie parametrów respiracji metodą oscylacji wymuszonych
PublicationCelem pracy jest weryfikacja praktycznej przydatności parametrów modeli procesu respiracji w diagnostyce układu oddechowego. Poddana ocenie została technika oscylacji wymuszonych. Wyniki badań eksperymentalnych zaczerpnięto z literatury. Wykorzystano cztero- i sześcioparametrowy model procesu respiracji. Estymaty parametrów porównano z wynikami badań przeprowadzonymi u osób, u których stwierdzono zaburzenia układu oddechowego....