dr inż. Krzysztof Czuszyński
Zatrudnienie
Publikacje
Filtry
wszystkich: 30
Katalog Publikacji
Rok 2017
-
Analysis of Properties of an Active Linear Gesture Sensor
PublikacjaBasic gesture sensors can play a significant role as input units in mobile smart devices. However, they have to handle a wide variety of gestures while preserving the advantages of basic sensors. In this paper a user-determined approach to the design of a sparse optical gesture sensor is proposed. The statistical research on a study group of individuals includes the measurement of user-related parameters like the speed of a performed...
-
Extending touch-less interaction with smart glasses by implementing EMG module
PublikacjaIn this paper we propose to use temporal muscle contraction to perform certain actions. Method: The set of muscle contractions corresponding to one of three actions including “single-click”, “double-click” “click-n-hold” and “non-action” were recorded. After recording certain amount of signals, the set of five parameters was calculated. These parameters served as an input matrix for the neural network. Two-layer feedforward neural...
-
Pose classification in the gesture recognition using the linear optical sensor
PublikacjaGesture sensors for mobile devices, which have a capability of distinguishing hand poses, require efficient and accurate classifiers in order to recognize gestures based on the sequences of primitives. Two methods of poses recognition for the optical linear sensor were proposed and validated. The Gaussian distribution fitting and Artificial Neural Network based methods represent two kinds of classification approaches. Three types...
Rok 2015
-
Application of smart glasses for fast and automatic color correction in health care
PublikacjaIn recent years different applications of smart glasses in health care have been proposed. In this paper we present the experiments related to automatic color correction using smart glasses platform developed within the eGlasses project. The color pattern is proposed and tested enabling the automatic detection of the pattern and automatic correction of colors. Additionally, the method for encoding and decoding of patient ID in...
-
Comparison of active proximity radars for the wearable devices
PublikacjaTwo methods of object position and movement estimation in relation to the user of smart glasses were investigated. An active infrared and ultrasonic methods of the obstacle detection were presented and compared. Application of these methods depend on active transducers type (physical medium used), geometry and surface properties of detected objects and their movement direction and speed. In the article properties of both detectors...
-
Feasibility Study for Food Intake Tasks Recognition Based on Smart Glasses
PublikacjaIn this exploratory study 13 adult test subjects have performed different food intake tasks while wearing a three axis accelerometer mounted at a temple of glasses. Two different algorithms for task recognition have been applied and compared. The retrospective data processing leads to better task recognition results when the frequency range of 50 Hz to 100 Hz is analysed within accelerometer signal recordings. A straightforward...
-
Interactions using passive optical proximity detector
PublikacjaIn this paper we evaluated the possible application of a passive, optical sensor as an interface for human-smart glasses interactions. The designed proximity sensor is composed of set of photodiodes and the appropriate hardware and software components. First, experiments were performed for the estimations of such parameters as distance to an object, its width and velocity. Achieved results were satisfactory. Therefore, next, a...
Rok 2013
-
Bezprzewodowy moduł detekcji źródeł dźwięku – system klasyfikatorów
PublikacjaMonitoring bezpieczeństwa osób starszych i chorych przebywających samotnie w pomieszczeniach można realizowaćpoprzez detekcję dźwięków nietypowych. W tym celu zbudowano moduł nasłuchujący, który analizuje dźwięki z otoczenia. Oblicza on szereg parametrów dźwięku, także bazujących na STFT i MFCC. Umożliwiają one wychwycenie i sklasyfikowanie takich odgłosów jak jęki, krzyki, kaszel oraz huki. Przedstawiono...
-
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublikacjaThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...
Rok 2018
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublikacjaThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
Digits Recognition with Quadrant Photodiode and Convolutional Neural Network
PublikacjaIn this paper we have investigated the capabilities of a quadrant photodiode based gesture sensor in the recognition of digits drawn in the air. The sensor consisting of 4 active elements, 4 LEDs and a pinhole was considered as input interface for both discrete and continuous gestures. Index finger and a round pointer were used as navigating mediums for the sensor. Experiments performed with 5 volunteers...
-
Gesture Recognition With the Linear Optical Sensor and Recurrent Neural Networks
PublikacjaIn this paper, the optical linear sensor, a representative of low-resolution sensors, was investigated in the multiclass recognition of near-field hand gestures. The recurrent neural network (RNN) with a gated recurrent unit (GRU) memory cell was utilized as a gestures classifier. A set of 27 gestures was collected from a group of volunteers. The 27 000 sequences obtained were divided into training, validation, and test subsets....
-
Optical Sensor Based Gestures Inference Using Recurrent Neural Network in Mobile Conditions
PublikacjaIn this paper the implementation of recurrent neural network models for hand gesture recognition on edge devices was performed. The models were trained with 27 hand gestures recorded with the use of a linear optical sensor consisting of 8 photodiodes and 4 LEDs. Different models, trained off-line, were tested in terms of different network topologies (different number of neurons and layers) and different effective sampling frequency...
-
Pose-Invariant Face Detection by Replacing Deep Neurons with Capsules for Thermal Imagery in Telemedicine
PublikacjaAbstract— The aim of this work was to examine the potential of thermal imaging as a cost-effective tool for convenient, non- intrusive remote monitoring of elderly people in different possible head orientations, without imposing specific behavior on users, e.g. looking toward the camera. Illumination and pose invariant head tracking is important for many medical applications as it can provide information, e.g. about vital signs, sensory...
Rok 2016
-
Cardiovascular data analysis using electronic wearable eyeglasses-preliminary study
Publikacjahe paper presents an alternative approach to the monitoring of the cardiovascular system. The study depicts configurations of the utilized system and preliminary results of electrical and mechanical parameters of the cardiac system which can be measured using a head-worn device.
-
EMG and gaze based interaction with graphic interface of smart glasses application
PublikacjaIn this paper we investigate the effectiveness of the interaction using eye tracking and electromyography. Smart glasses requires reliable interfaces for controlling the graphic content displayed directly in front of the user's eye. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublikacjaRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublikacjaIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
Rok 2014
-
Impact of surface skin temperature change on blood flow characteristics in palm
PublikacjaHeating a human palm during 3 minutes period causes changes in superficial skin temperature and leads to thermoregulation system response. The response time and level of flow characteristics change depend on the subject hand size and health of his vascular tree. A solution of Pennes bioheat propagation model was analyzed in order to see how much heat has to be transferred into the tissue to extort the observable reaction. The reflective...
-
Interaction with medical data using QR-codes
PublikacjaBar-codes and QR-codes (Quick Response ) are often used in healthcare. In this paper an application of QR-codes to exchange of laboratory results is presented. The secure data exchange is proposed between a laboratory and a patient and between a patient and Electronic Health Records. Advanced Encryption Standard was used to provide security of data encapsulated within a QR-code. The experimental setup, named labSeq is described....
wyświetlono 753 razy