Biocompatibility and bioactivity of bearing loaded metallic implants
PublikacjaPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures
PublikacjaBackground: Intertrochanteric fractures may occur in a bone with a wide medullary canal that may lead to significant mobility of a intramedullary nail, contrary to an extramedullary device. This study evaluates the Dynamic Hip Screw and the gamma nail in AO 31.A2.1 fractures in these circumstances. Methods: Synthetic femora with canals drilled to 18 mm were used. Five fixation types were examined: a 2 - hole and a 4 – hole Dynamic...
-
Validation of Hydraulic Mechanism during Blowout Trauma of Human Orbit Depending on the Method of Load Application
PublikacjaThe more we know about mechanisms of the human orbital blowout type of trauma, the better we will be able to prevent them in the future. As long as the buckling mechanism’s veracity is not in doubt, the hydraulic mechanism is not based on equally strong premises. To investigate the correctness of the hydraulic mechanism’s theory, two different methods of implementation of the hydraulic load to the finite element method (FEM) model...
-
Mechanical and structural investigations of wings of selected insect species
PublikacjaThis paper presents research and measurements leading to obtaining the Young’s modulus of wing bearing structures of selected insect species. A small testing machine intended for three-point bending and equipped with instruments registering low forces was constructed for the needs of the experiment. The machine was used to perform numerous bending tests of wings of three species of insects (obtained from a breeding farm): Attacus...
-
The Influence of External Additional Loading on the Muscle Activity and Ground Reaction Forces during Gait
PublikacjaAsymmetrical external loading acting on the usculoskeletal system is generally considered unhealthy. Despite this knowledge, carrying loads in an asymmetrical manner like carrying on one shoulder, with one hand, or on the strap across the torso is a common practice. This study is aimed at presenting the effects of the mentioned load carrying methods on muscle activity assessed by using thermal field and ground reaction forces....
-
Analysis of muscles behaviour. Part II. The computational model of muscles group acting on the elbow joint
PublikacjaThe purpose of this paper is to present the computational model of muscles' group describing the movements of flexion/extension at the elbow joint in the sagittal plane of the body when the forearm is being kept in the fixed state of supination/pronation. The method ofevaluating the muscle forces is discussed in detail. This method is the basis for the quantitative and qualitative verification of the proposed computational model...
-
Tribology of the cartilage cells in the intelligent bioreactor
PublikacjaW badaniach analityczno-numerycznych wyznaczone zostały pola prędkości przepływu lepkosprężystej, odżywczej nienewtonowskiej cieczy biologicznej, a także powstające siły tarcia w trakcie hodowli w warstwie granicznej wokoło powierzchni hodowanych komórek w bioreaktorach, stawach człowieka oraz w szczelinach mikrołożysk. Dodatkowo rozpatrywane będą przepływy potencjalne płynu stawowego z jamy stawowej, które odżywiają chrząstkę...
-
Hydrodynamic pressure in micro-and nano bearing gap
Publikacja.
-
Mechanical behaviour of knit synthetic mesh used in hernia surgery
PublikacjaPurpose: There is a discussion in literature concerning mechanical properties and modelling of surgical meshes. An important feature of elastic modulus dependency on load history is taken into account in this paper, as implants are subjected to variable loading during human activity. The example of DynaMesh®-IPOM surgical implant is studied. Methods: The analysis is based on failure tension tests and cyclic loading and unloading...
-
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublikacjaIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
Influence of geometry and annealing temperature in argon atmosphere of TiO2 nanotubes on their electrochemical properties
Publikacja -
Application of muscle model to the musculoskeletal modeling
PublikacjaThe purpose of this paper is to investigate new fusiform muscle models. Each of these models treats a muscle as a system composedof parts characterized by different mechanical properties. These models explain the influence of differences in the stiffness of lateral parts and the degree of muscle model discretization. Each muscle model is described by a system of differential equations and a single integro-differential equation....
-
Method for assessing the dynamics and efficiency of diving fins
Publikacja -
Modelling and simulation of striated muscle and groups of muscles in arm-forearm system 2D
PublikacjaModel mięśnia szkieletowego poprzecznie prążkowanego został przedstawiony jako szeregowe połączenie aktywnych i pasywnych odcinków reologicznych. Zasymulowane zostały: skurcze pojedyncze, niecałkowity skurcz tężcowy, całkowity skurcz tężcowy. Model zespołu mięśni w układzie ramię-przedramię opisu-je zmianę kąta obrotu przedramienia względem nieruchomego ramienia. Pobudzając zginacze i prostowniki był zasymulowany obrót przedramienia.
-
Estimation of flow for tissue perfusion of nutrient liquids in bioreactor.
PublikacjaPrzedstawione zostały problemy związane z wyznaczaniem pola prędkości w warstwie przyściennej opływanej tkanki miękkiej w bioreaktorze. Warunki brzegowe na powierzchni miękkiej tkanki o właściwościach porowatych zostały w niniejszej pracy sformułowane.
-
Dynamic characteristics of interaperitoneal perfusion.
PublikacjaPrzedstawiono wyniki badań laboratoryjnych perfuzyjnego przepływu przez model jamy brzusznej człowieka. Szczególną uwagę zwrócono na techniczne aspekty modelu oraz wyników badań. Omówiono technikę pomiarową oraz przeanalizowano rezultaty pod kątem teorii przepływów przez zbiorniki i reaktory.
-
Deposition of phosphate coatings on titanium within scaffold structure
PublikacjaPurpose: Existing knowledge about the appearance, thickness, and chemical composition of phosphate coatings on titanium inside porous structures is insufficient. Such knowledge is important for the design and fabrication of porous implants. Methods: Metallic scaffolds were fabricated by selective laser melting of 316L stainless steel powder. Phosphate coatings were deposited on Ti sensors placed either outside the scaffolds or...
-
The effective elastic properties of human trabecular bone may be approximated using micro-finite element analyses of embedded volume elements.
PublikacjaBoundary conditions (BCs) and sample size affect the measured elastic properties of cancellous bone. Samples too small to be representative appear stiffer under kinematic uniform BCs (KUBCs) than under periodicity-compatible mixed uniform BCs (PMUBCs). To avoid those effects, we propose to determine the effective properties of trabecular bone using an embedded configuration. Cubic samples of various sizes (2.63, 5.29, 7.96, 10.58...
-
Analysis of muscles behaviour : The computational model of muscle. -Part I
PublikacjaW artykule zaproponowano model obliczeniowy mięśnia szkieletowego, który potraktowano jako strukturę o złożonych i zróżnicowanych właściwościach mechanicznych. Szczegółowo opisano metodę identyfikacji tych właściwości. Ponadto określono sposób przeprowadzenia weryfikacji ilościowej i jakościowej zaproponowanego modelu. Za pomocą takiego obliczeniowego modelu mięśnia można łatwo określać siły w mięśniach, które należą do zespołu...
-
Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction
PublikacjaCementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the rough surface of the implant, a process called osseointegration. However, debonding of the bone–implant interface can still occur due to aseptic implant loosening and insufficient osseointegration, which may have dramatic consequences. The aim of this work is to...