Wyniki wyszukiwania dla: NATURAL ORIFICE TRANSLUMENAL ENDOSCOPIC SURGERY, MAGNETIC INSTRUMENTATION, SURGICAL TECHNOLOGY
-
Magnetic instrumentation and other applications of magnets in NOTES
PublikacjaModern surgery is developing towards a minimally invasive approach. To minimize the trauma the number of ports is either limited as in single incision laparoscopic procedures or ports are introduced through natural orifices as in nat- ural orifice translumenal endoscopic surgery (NOTES). To provide surgeons with appropriate instrumentation novel technologies are employed involving magnets. This article summarizes the theoretical...
-
Surgical Site Infection after Breast Surgery: A Retrospective Analysis of 5-Year Postoperative Data from a Single Center in Poland
PublikacjaBackground and Objectives: Surgical site infection (SSI) is a significant complication of non-reconstructive and reconstructive breast surgery. This study aimed to assess SSI after breast surgery over five years in a single center in Poland. The microorganisms responsible for SSI and their antibiotic susceptibilities were determined. Materials and Methods: Data from 2129 patients acquired over five years postoperatively by the...
-
Inspection of Gas Pipelines Using Magnetic Flux Leakage Technology
PublikacjaMagnetic non-destructive testing methods can be classified into the earliest methods developed for assessment of steel constructions. One of them is the magnetic flux leakage technology. A measurement of the magnetic flux leakage is quite commonly used for examination of large objects such as tanks and pipelines. Construction of a magnetic flux leakage tool is relatively simple, but a quantitative analysis of recorded data is a...
-
NEW DESIGNS OF CENTRIFUGAL MAGNETIC FLUID SEALS FOR ROTATING SHAFTS IN MARINE TECHNOLOGY
PublikacjaThe centrifugal magnetic fluid seals have important advantage over the conventional centrifugal seals. They maintain very good sealing capacity at static, medium and high speeds of shaft rotation, with the increased seal lifetime, and minimum torque and static friction. These seals are particularly useful in cases when the angular shaft velocity varies and sometimes decreases to nearly or exactly zero, such as in flywheel applications,...
-
Revisional operations among patients after surgical treatment of obesity: a multicenter Polish Revision Obesity Surgery Study (PROSS)
Publikacja -
Elective surgery system strengthening: development, measurement, and validation of the surgical preparedness index across 1632 hospitals in 119 countries
Publikacja -
The study on possibilities of recovery non-magnetic fraction by utilisation the magnetic separation technology in conditions of KGHM Polska Miedz S.A. division of concentrators = Próby odzysku frakcji niemagnetycznej metodą separacji magnetycznej w warunkach KGHM Polska Miedź S.A. Oddział Zakłady Wzbogacania Rud
PublikacjaW referacie przybliżono wyniki badań prowadzonych w kierunku określenia możliwości odzysku frakcji niemagnetycznej i słabomagnetycznej ze strumieni materiałowych O/ZWR, poprzez wykorzystanie metody separacji magnetycznej. Przeprowadzony cykl badawczy obejmował analizę występowania frakcji magnetycznej i związanej z nią frakcji niemagnetycznej w obiegach technologicznych w Rejonie ZWR Lubin, oraz możliwości ich odzysku. Uzyskane...
-
Surgical site infection after gastrointestinal surgery in high-income, middle-income, and low-income countries: a prospective, international, multicentre cohort study
Publikacja -
Numerical Estimate of the Spectral Resonance Structure Frequency Scale of Natural ULF Magnetic Field
Publikacja -
Instrumentation optical fibres for wave transformation, signal processing, sensors, and photonic functional components, manufactured at Białystok University of Technology in Dorosz Fibre Optics Laboratory
Publikacja -
Exploring the cost-effectiveness of high versus low perioperative fraction of inspired oxygen in the prevention of surgical site infections among abdominal surgery patients in three low- and middle-income countries
Publikacja -
Projekt robotycznego mikro-nadgarstke dla potrzeb chirurgii laparoskopowej wykonany w technologii MEMS = The project of robotic micro-wrist for the laparoscopic surgery, made in MEMS technology
PublikacjaArtykuł przedstawia proces projektowania robotycznego mikro-nadgarstka dla potrzeb chirurgii laparoskopowej przy zastosowaniu technologii MEMS (z ang. MicroElectroMechanicalSystems) i oryginalnej architektury 3D o trzech stopniach swobody. Mikro-laparoskopia, inaczej igłoskopia (z ang. needlescoopy), jest obecnie jednym z nowo kształtujących się tematów w dziedzinie robotyki medycznej o perspektywach szybkiego rozwoju. Operacja...
-
Comprehensive Review of Fluorescence Applications in Gynecology
PublikacjaSince the introduction of indocyanine green (ICG) as a fluorophore in near-infrared imaging, fluorescence visualization has become an essential tool in many fields of surgery. In the field of gynecology, recent new applications have been proposed and found their place in clinical practice. Different applications in gynecology were investigated, subcategorized, and overviewed concerning surgical applications and available dyes....
-
3D-Breast System for Determining the Volume of Tissue Needed for Breast Reconstruction
Publikacja3D imaging systems can be used to effectively determine breast volumes for surgical applications. This article presents methods for surface reconstruction and volume determination based on the point cloud created by 3D imaging. Such a system would be used to accurately estimate breast volume in patients classified for breast reconstruction surgery at plastic surgery centers. To develop such a system, various methods of determining...
-
"3D-Breast System for Determining the Volume of Tissue Needed for Breast Reconstruction"
PublikacjaThis article presents methods for surface reconstruction and volume determination based on the point cloud created by 3D imaging. Such a system would be used to accurately estimate breast volume in patients classified for breast reconstruction surgery at plastic surgery centers. To develop such a system, various methods of determining volume, based on images from the Intel D435i camera, were tested. In addition, an application...
-
Tools for Automatic Wound Healing Evaluation
PublikacjaFinal results of the research project devoted to development of a new objective and quantitative method of post cardiosurgery wound healing diagnostics, already preliminary discussed at the QIRT 2014 Conference, is presented. We assumed that thermal processes should be effective in subtle description of temporal changes of tissue thermal properties after surgical interventions. To prove this assumption more than 400 patients after...
-
Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study
PublikacjaThe aim of this study was to test the accuracy of ultrasonography performed by gynecological oncologists for the preoperative assessment of epithelial ovarian cancer (EOC) spread in the pelvis and abdominal cavity. A prospective, observational cohort study was performed at a single tertiary cancer care unit. Patients with suspected EOC were recruited and underwent comprehensive transvaginal and abdominal ultrasonography performed...
-
Polyurethanes modified with natural polymers for medical application. I. Polyurethanes/ Chitosan and polyurethane/collagen.
PublikacjaFor over three decades polyurethanes (PUR or PU) have been reported for application in a variety of medical devices. These polymers consist of hard and soft segments, which allow for more subtle control of their structure and properties. By varying the composition of the different segments, properties of PURcan be tuned up for use in many areas of medicine. Recently there is a great interest in modification of biomedical PUR with...
-
Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
PublikacjaIn this paper, a tuning method of a resonant circuit suited for wireless powering of miniature endoscopic capsules is presented and discussed. The method allows for an automatic tuning of the resonant frequency and matching impedance of a full wave rectifier loading the resonant circuit. Thereby, the receiver tunes so as to obtain the highest power efficiency under given conditions of transmission. A prototype receiver for wireless...
-
Three-Dimensional Printing of Bone Models
PublikacjaThe trabecular bone occurs, for example, in the femoral heads. Understanding the phenomenon of bone tissue degeneration can be the basis for the possibility of looking for alternative methods of surgical treatment of bone loss. The paper presents the results of the trabecular bone model, which was produced in additive manufacturing method with fused filament fabrication technology. The verification of the mechanical behavior of...