Filtry
wszystkich: 3710
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: low%20frequency%20enhancement
-
Marek Pszczoła dr hab. inż.
OsobyI am a Faculty member (Department of Highway and Transportation Engineering) at the Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Poland). My main research interests include: low-temperature properties of asphalt mixtures, low temperature cracking assessment of pavement structures, road materials properties, thermal stress analysis, design of pavement structures, airfield design and analysis....
-
The Medieval Low Countries
Czasopisma -
Low-coherence method of hematocrit measurement
PublikacjaDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublikacjaAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Journal of Low Power Electronics
Czasopisma -
Healthcare in Low-resource Settings
Czasopisma -
International Journal of Low Radiation
Czasopisma -
Early Modern Low Countries
Czasopisma -
JOURNAL OF LOW TEMPERATURE PHYSICS
Czasopisma -
LOW NOISE TIRES FOR HYBRID AND ELECTRIC VEHICLES
PublikacjaLow Emission Vehicles that are hybrid and electric cars may benefit from specially designed tires that are optimized for driving conditions typical for such vehicles. It is possible that in the future Low Emission Vehicles, especially passenger cars, will substitute conventional vehicles in all applications, however for the time being they are mostly used in urban and suburban areas. Urban traffic has a rather low demand for grip...
-
Novel Low-Loss Substrates for 5G Applications
PublikacjaThis paper presents a feasibility study of a new type of microwave low-loss dielectric substrates for 5G network applications. The new substrate materials are composites of polypropylene and high-dielectric-constant micro-ceramics. This combination is expected to form a very low-loss dielectric material at low fabrication cost. Two substrate samples with different dielectric properties are fabricated and their characteristics at...
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013782931]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013783131]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013786841]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013783241]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013784491]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 40 - Tissue image [7040247104932011]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 40 - Tissue image [630073002825231]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 40 - Tissue image [6300730028253261]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublikacjaThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
The use of low-coherence interferometer for sugar content determination
PublikacjaIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
Low grade serous carcinoma - Female, 58 - Tissue image [10010729534326341]
Dane BadawczeThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Low grade serous carcinoma - Female, 58 - Tissue image [10010729534339021]
Dane BadawczeThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Evaluation of Low Temperature Properties of Rubberized Asphalt Mixtures
PublikacjaThe paper presents low-temperature test results of asphalt mixtures designed with use of bitumen modified by crumb rubber and also SBS polymer. Laboratory tests were conducted on two types of asphalt mixtures for wearing course – stone matrix asphalt (SMA 8) and porous asphalt (PA 8). This paper presents results of the following laboratory tests at low temperatures: TSRST test, three point bending creep test, fracture toughness...
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026743851]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [617073002674451]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026749991]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026745981]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [11020630022696911]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [11020630022699761]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [3300730069458321]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [11020630022694241]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [11020630022694071]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [3300730069455341]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [11020630022693991]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [11020630022693501]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intraductal papillary mucinous neoplasm with low grade dysplasia - Male, 72 - Tissue image [11020630022694651]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Low-Cost Surrogate Models for Microwave Filters
PublikacjaA novel low-cost kriging-based multivariable parametric macromodeling technique for microwave filters is presented. Kriging is used to model both the residues and poles of a microwave filter's reflection coefficient, and the zeros of the transmission coefficient. The proposed residue-pole-zero (RPZ) technique is demonstrated to efficiently model a high dimensional (8D) microwave filter with pseudoelliptic characteristics.
-
Low-energy interactions related to atmospheric and extreme conditions
PublikacjaThis Topical Issue, entitled “Low-Energy Interactions Related to Atmospheric and Extreme Conditions”, showcases a collection of eighteen articles that reported recent theoretical and experimental findings pertaining to the following topics: – low-energy interactions of charged particles (electrons [1–7], protons [8], positrons [9]), and photons [10] with atoms and molecules of biological [1–4,7,8], astrochemical [10], industrial,...
-
Multipulse inverter structures with low voltage distortion
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
International Journal of Low-Carbon Technologies
Czasopisma -
Journal of Low Power Electronics and Applications
Czasopisma -
Pedestrian detection in low-resolution thermal images
PublikacjaOver one million people die in car accidents worldwide each year. A solution that will be able to reduce situations in which pedestrian safety is at risk has been sought for a long time. One of the techniques for detecting pedestrians on the road is the use of artificial intelligence in connection with thermal imaging. The purpose of this work was to design a system to assist the safety of people and car intelligence with the use...
-
Assessment of Supercapacitor’s Quality by Means of Low Frequency Noise
PublikacjaLow frequency noise is a well-known tool for quality and reliability assessment of electronic devices. This phenomenon is observed in different electrochemical devices as well (e.g., smart windows, electrochemical corrosion processes). Thus, we can assume that the same tool can be used to asses quality of supercapacitors. Their quality is usually determined only by capacitance and/or equivalent series resistance (ESR), or impedance....
-
Corrosion of evaporator tubes in low emission steam boilers
PublikacjaPurpose of this paper is to reveal the mechanisms of corrosion processes of outer surfaces of low-emission steam boiler evaporator tubes. Examinations were performed to find the reasons of different corrosion susceptibility of tubes situated at combustion chamber on various levels. Examinations were conducted on several segments of 57 x 5.0 mm evaporator tubes made of 16M (16Mo3) steel grade. Segments were taken from level of...
-
Poroelastic Low Noise Road Surfaces
PublikacjaNoise is one of the most important problems related to road traffic. During the last decades, noise emitted by engine and powertrain of vehicles was greatly reduced and tyres became a clearly dominant noise source. The paper describes the concept of low noise poroelastic road surfaces that are composed with mineral and rubber aggregate bound by polyurethane resin. Those surfaces have a porous structure and are much more flexible...
-
Dedicated power supply subsystem for ultra-low noise preamplifiers
PublikacjaIn field of electronics there is need for low-noise amplifiers. Noise have the most important influence on analog circuits. Therefore exist necessity to develop new ultra-low noise power supplies, which can cooperate with specified amplifiers and preamplifiers. It is very common that professional power supplies are very expensive and still have disadvantages. This paper proposes simple and inexpensive solution, which fulfill specific...
-
Low Power Baseband Processor for M2M Reconfigurable Radio Test Platform
PublikacjaSoftware Defined Radio (SDR) is becoming more andmore frequently used technique for wireless communication. Itfacilitates as fast prototyping and is a versatile method fordeveloping new communication systems. SDR can be realizedbased on high computational capacity platform, where powerconsumption is no a primary concern like i.e. DVB or BTStransmitters. Another trend are low power systems, whereavailable power in reduced and more...
-
PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES
Czasopisma -
On the use of a charge balancing method for low energy measurements
PublikacjaThe paper presents the method for the estimation of the energy consumption of the low-power microcontroller-based devices. Due to high dynamics of the changes of the supply current of the tested devices during the operational cycle, the consumed energy estimation is not easy. In order to avoid disadvantages of known methods, the charge balancing method was employed similarly like in some types of A/D converters.