Wyniki wyszukiwania dla: voltage source inverter (vsi)
-
Space-vector pulsewidth modulation for a seven-level cascaded H-bridge inverter with the control of DC-link voltages
PublikacjaThe control strategy of DC-link voltages for a seven-level Cascaded H-Bridge inverter is proposed in this paper. The DC-link voltage balancing is accomplished by appropriate selection of H-Bridges and control of their duty cycles in Space-Vector Modulation (SVM) algorithm. The proposed SVM method allows to maintain the same voltage level on all inverter capacitors. Regardless of the balancing function, the...
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublikacjaMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Resonant DC link inverters for AC motor drive systems – critical evaluation
PublikacjaIn this survey paper, resonant and quasiresonant DC link inverters are reexamined for AC motor drive applications. Critical evaluation of representative topologies is based on simulation and waveform analysis to characterize current/voltage stress of components, control timing constraints and feasibility. A special concern over inverter common-mode voltage and voltage gradient du/dt limitation capacity is discussed for motor bearing...
-
A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters
PublikacjaMultiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...
-
A Five-Leg Three-Level Dual-Output Inverter
PublikacjaClassical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...
-
Formowanie wektorów napięcia wyjściowego w pięciofazowych falownikach napięcia
PublikacjaW falownikach pięciofazowych, załączenie wektorów aktywnych powoduje jednoczesne formowane dwóch, zależnych od siebie wektorów napięcia wyjściowego. Sterowanie pięciofazowymi silnikami indukcyjnymi wymaga, aby wektory te miały ściśle określone długości i położenia. Niezależne formowanie dwóch wektorów napięcia o parametrach określonych w układzie sterowania silnikiem wymaga zastosowania odpowiedniej strategii Modulacji Szerokości...
-
Novel single-stage buck-boost inverter with unfolding circuit
PublikacjaA novel solution of a single-stage buck-boost inverter with unfolding circuit at the output stage is presented. The inverter has a wide range of input voltage regulation, minimum passive components and a very flexible control structure. It can be applied for renewable energy systems where high power density is required. Our simulation results confirmed all theoretical statements
-
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
PublikacjaIn this paper the predictive estimation based control strategy for a quasi-resonant dc link inverter (PQRDCLI) is developed. Instead of direct measurement of dc link input inverter current – its estimation with one step prediction is applied. The PQRDCLI fed induction motor, controlled with a predictive current estimation stabilized inverter output voltage slopes independently of load. Moreover, reduction of overvoltage spikes...
-
Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator
PublikacjaDue to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...
-
Regulacja napięcia w sieci nN z rozproszonymi źródłami energii
PublikacjaPodłączanie rozproszonych źródeł energii do sieci energetycznych niskiego napięcia powoduje powstawanie problemów zmienności i niesymetrii napięcia, zwłaszcza w przypadku dużych odległości od transformatora zasilającego. W skrajnych przypadkach zachodzi konieczność redukcji mocy generowanej przez źródło podczas oddawaniu energii do sieci. Rozwiązaniem tego problemu jest zastosowanie energoelektronicznego regulatora napięcia składającego...
-
Kompleksowa analiza symulacyjna układu napędowego zespołu trakcyjnego
PublikacjaThe paper describes an approach to comprehensive analysis of traction electric drive. The drivetrain of ED-74 electric unit equipped with four inverter-fed induction motors was modeled in Matlab/Simulink. The model consists of functional blocks as: motors, inverters, drive controllers, filters. Structure and operation of the model was described. Chosen simulation results were presented and discussed. Two methods of modeling the...
-
A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.
PublikacjaIn this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...
-
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublikacjaThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublikacjaThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter
PublikacjaThe control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...
-
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublikacjaIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublikacjaDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
A Simplified SVPWM Technique for Five-leg Inverter with Dual Three-phase Output
PublikacjaThis article proposes a simplified space vector pulse-width modulation (SVPWM) technique five-leg inverter with dual three-phase output. An idea to fed the dual tree-phase machine by the multiphase voltage source inverters (VSIs) is not new. Dual- and multi-motor drive systems are widely used in the industry applications. The most popular fields are: electric vehicles (EVs) and traction systems. Moreover, the specific characteristic...
-
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublikacjaThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...
-
Comprehensive distortion compensation of grid-connected inverter currents
PublikacjaThe paper presents a comprehensive approach to the compensation of phase current distortion of grid-connected power inverters. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, voltage fluctuations in the dc link, time delays in the estimation of grid voltages, and the distortion of inverter output voltages due to dead-time effects and related...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublikacjaThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublikacjaThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Modeling the impact of rotor movement on non-linearity of motor currents waveforms in high-speed PMSM drives
PublikacjaMotor current measurement techniques as well as predictive control algorithms for electric drives rely on an assumption of linear motor currents changes resulting from constant inverter output voltages. Recent research has reported that this assumption does not hold in motors with short electrical time constant, and in drives whose rotor position advances substantially during a control period. This paper proposes a simulation model...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublikacjaThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Solutions of inverter systems in Shore-to-Ship Power supply systems
PublikacjaThe article presents a clearly formulated need for installing S2SP (Shore to Ship Power) systems, in particular Medium Voltage (MV) systems, along with certain solutions of modern inverter systems used in those systems. Requirements and basic configurations of S2SP systems are discussed, focusing in particular on capabilities of the S2SP system with DC distribution busbar. Moreover, on the background of the executing assumptions...
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublikacjaThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Impact of digital signal processing on FOC current feedback in high-speed PMSM drive
PublikacjaIn applications where size and weight of the electric motor are among major design concerns, Permanent Magnet Synchronous Motors (PMSMs) with wide operational speed-range are commonly preferred. Due to limited inverter switching frequency, high-speed operation of a drive results in a low ratio between the switching frequency and the fundamental frequency of motor voltage. Such operating conditions have been recently identified...
-
Synteza bezczujnikowego sterowania maszyną indukcyjną klatkową zasilaną z falownika prądu
PublikacjaSynteza bezczujnikowego sterowania maszyną indukcyjną klatkową zasilaną z falownika prądu stanowi cel niniejszej monografii. Praca zawiera podstawowe informacje na temat modelowania układu napędowego z maszyną indukcyjną klatkową zasilaną z falownika prądu. Przedstawiono informacje na temat linearyzacji nieliniowych obiektów. Na pod-stawie metody syntezy strukturalnej opracowano nowe transformacje do postaci zmien-nych multiskalarnych,...
-
EMC disturbances in connection of driving system
PublikacjaIt is known the steep voltage changes caused by IGBT frequency inverters may cause some electromagnetic problems in driving system. Special dU/dt type as well as sinusoidal filters are used in order to limit the level of the disturbances. The paper presents investigation results of EMC disturbances in inverter supplied induction motor. Experiments have proved that disturbances in current connection differ essentially. Important...
-
Space vector modulation in multilevel inverters of the servo drives of the trajectory measurements telescopes
PublikacjaUsing the MatLab/Simulink mathematical model of a three-phase three-level voltage inverter, the influence of the space-vector modulation (SVM) algorithm on the pulsations of the current (torque) of an AC motor in the range of low rotation speeds is considered. It is shown that the SVM of the second kind does not provide a pulsations level comparable to the pulsations of a sinusoidal pulse-width modulation (SPWM), both in the static...
-
Hybridized PWM Strategy for Three- and Multiphase Three-Level NPC Inverters
PublikacjaA simple hybridized pulsewidth modulation (PWM) algorithm for three- and multiphase three-level neutral point clamped (NPC) inverters is proposed. The proposed solution is based on classical space vector PWM (SVPWM) algorithms for two-level inverters but can also be based on sinusoidal PWM with min–max injection. An additional level of output voltage is obtained by modifying the resulting switching patterns taking into account...
-
Wireless Charging Station Design for Electric Scooters: Case Study Analysis
PublikacjaThis study proposes an example of a wireless charging station design for a small-scale vehicle available on the market. The article analyzes basic transmitter inverter topologies and their compensation methods in terms of flexibility of control, tolerance to uncertainty in positioning, and the possibility of decreasing the integration price. Our comprehensive analysis focuses on the battery voltage range, energy capacity, cost,...
-
Selective Harmonic Elimination PWM For a Cascaded Multi-level Inverter
PublikacjaThis paper deals with the selective harmonic elimination pulse width modulation (SHE-PWM) technique. This technique is used for the elimination of selected dominant low order harmonics in the multi-level inverter output voltage. The presence of these harmonics is the essential drawback of such kind of inverters; especially when it is used for the control of different AC drivers. The SHE-PWM is based...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublikacjaThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Broken rotor symptoms in the sensorless control of induction machine
PublikacjaThe purpose of this paper is to investigate the need for a universal method for sensorless controlled induction motor drive diagnosis. The increasing number of sensorless control systems in industrial applications require a universal method for the drive diagnosis, which provides reliable diagnostic reasoning independent of control system structure and state variables measurement or estimation method.Simulations and experimental...
-
Design and experimental validation of a single-stage PV string inverter with optimal number of interleaved buck-boost cells.
PublikacjaIncreasing converter power density is a problem of topical interest. This paper discusses an interleaved approach of the efficiency increase in the buck-boost stage of an inverter with unfolding circuit in terms of losses in semiconductors, output voltage ripples and power density. Main trends in the power converter development are reviewed. A losses model was designed and used for the proposed solution to find an optimal number...
-
Sensorless Multiscalar Control of Five-Phase Induction Machine with Inverter Output Filter
PublikacjaThe paper presents a complete solution for speed sensorless control system for five-phase induction motor with voltage inverter, LC filter and nonlinear control of combined fundamental and third harmonic flux distribution. The control principle, also known as multiscalar control, nonlinear control or natural variables control, is based on a use of properly selected scalar variables in control feedback to linearize controlled system....
-
Control system for contactless electrical energy transfer with varying air gap
PublikacjaInductive power transfer (IPT) is a system by which electrical energy may be transmitted without electrical connection through a large air gap between coils. Systems usually considered in the literature are the ones with a constant air gap. The paper describes the analysis of IPT, which allows for supplying an electrical load in the conditions of slow, in relation to the dynamics of power supply, changes in the dimensions of the...
-
Marek Adamowicz dr hab. inż.
OsobyStopień naukowy doktora uzyskał w 2008 r. na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej. W latach 2005 – 2011 pracował na Akademii Morskiej w Gdyni. W 2010 r. jako laureat programu NCBR LIDER wybrał Wydział Elektrotechniki i Automatyki Politechniki Gdańskiej jako jednostkę realizującą swój projekt z zakresu szerokopasmowych przyrządów półprzewodnikowych i ich zastosowań w elektrowniach wiatrowych. Od 2011 roku...
-
Application of Barycentric Coordinates in Space Vector PWM Computations
PublikacjaThis paper proposes the use of barycentric coordinates in the development and implementationof space-vector pulse-width modulation (SVPWM) methods, especially for inverters with deformed space-vector diagrams. The proposed approach is capable of explicit calculation of vector duty cycles, independentof whether they assume ideal positions or are displaced due to the DC-link voltage imbalance. The use ofbarycentric coordinates also...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublikacjaThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Dynamic variables limitation for backstepping control of induction machine and voltage source converter
PublikacjaDynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...
-
Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors
PublikacjaThis paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...
-
Comparison of Impedance-Source Networks for Two and Multilevel Buck–Boost Inverter Applications
Publikacjampedance-source networks are an increasingly popular solution in power converter applications, especially in single-stage buck-boost power conversion to avoid additional front-end dc-dc power converters. In the survey papers published, no analytical comparisons of different topologies have been described, which makes it difficult to choose the best option. Thus, the aim of this paper is to present a comprehensive analytical comparison...
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublikacjatIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
New type T-Source inverter
Publikacja -
Exact generation of voltage vector in voltage inverter with pulse width modulation
PublikacjaW artykule zaproponowano metodę modulacji szerokości impulsów dla falownika napięcia. Proponowana metoda rozwiązuje problemy związane z kompensacją czasów martwych oraz kompensacją wpływu parametrów łączników energolelektronicznych na napięcie wjściowe falownika. W artykule zaprezentowano metodę kompensacji między innymi pojemności pasożytniczych tranzystorów, dyskretyzacji czasów załączeń tranzystorów. Przedstawiona metoda modulacji...
-
Innovative Bidirectional Isolated High-Power Density On-Board Charge for Vehicle-to-Grid
PublikacjaThis paper deals with developing and implementing a bidirectional galvanically isolated on-board charger of a high-power density. The power density of the new charger was 4 kW/kg and 2.46 kW/dm3, and the maximum efficiency was 96.4% at 3.4 kW. Due to the requirement to achieve a high-power density, a single-stage inverter topology was used. Regarding switching losses, due to the topology of the circuit with so-called hard switching,...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Over-Voltage Studies in Inverter Fed Induction Motor Drives
PublikacjaW pracy przedstawiono metodę identyfikacji pojemności pasożytniczych uzwojeń silników asynchronicznych uwzględniającą ich rozłożony charakter. Przedstawiony szerokopasmowy model obwodowy uzwojeń silnika asynchronicznego pozwala na modelowanie zjawisk przepięciowych w silnikach asynchronicznych, w szczególności zasilanych poprzez przekształtniki energoelektroniczne. Zaproponowana metoda analizy umożliwia również określanie składowych...