Wyniki wyszukiwania dla: CABLE-STAYED BRIDGE
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Induced sheath voltages in 110 kV power cables – case study
PublikacjaThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Position Estimation in Corridors Along the Coupled Mode of Radiating Cables
PublikacjaRadiating cables are mostly used to provide radio communication in tunnels or corridors, but they can also be used to estimate the position of a mobile terminal along the cable. In this paper, a measuring receiver’s position was estimated by measuring the difference in the direct signal’s reception time, which was generated by a transmitter connected to one end of the radiating cable, and the delayed signal retransmitted from another...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublikacjaThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublikacjaLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Subjective and Objective Quality Evaluation Study of BPL -PLC Wired Medium
PublikacjaThis paper presents results of research on the effectiveness of bi-directional voice transmission in a 6 kV mine cable network using BPL-PLC (Broadband over Power Line - Power Line Communication) technology. It concerns both emergency cable state (supply outage with cable shorted at both ends) and loaded with distorted current waveforms. The narrowband (0.5 MHz–15 MHz) and broadband (two different modes, frequency range of 3 MHz–7.5...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
How it audit can help your communications branch company increase effectiveness of using it technologies and contributes to implementation of business
PublikacjaText based on the example of Cable Television Ltd. Co. in Koszalin.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublikacjaThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Kacper Szturgulewski mgr inż.
OsobySpecjalista naukowo-techniczny w Politechnice Gdańskiej, wiodącej technicznej uczelni badawczej w Polsce. W chwili obecnej zajmuje się wysokoefektywnymi systemami energetycznymi z wykorzystaniem odnawialnych źródeł energii oraz technologii magazynowania energii. Uczestniczę w międzynarodowym projekcie Horizon Europe - 2LIPP (2nd Life for Power Plants), będącym częścią inicjatywy BRIDGE. Dodatkowo, aktywnie angażuje się w inicjatywy...
-
Composite Sandwich Footbridge – Numerical ESL FEM Calculations vs. In Situ Measurements
PublikacjaSelected results of the static analysis of composite sandwich footbridge with the corresponding in situ measured values are compared in the paper. The analysed bridge is a research object, which was built in 2015 and is currently located at the Gdańsk University of Technology campus. Since it is a novel structure, a proper definition of the bridge numerical model, allowing its safe design, is very important. Therefore, instead...
-
A1-S6 Rebielcz Raduńska 2016 - video data
Dane BadawczeThe video cameras installed on the Expressway S6 and motorway A1: 4 cameras in both directions, location: main road registered vehicles along the entire length of the road section. Cameras were mounted on 5-7 meter high masts. Date 29-31.07.2016
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublikacjaLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
The Impact of Thermal Stresses on Volume Resistivity: Performance Comparison between TR-XLPE and XLPE Cables
PublikacjaMost failures in electric power cables are attributed to the development of water trees inside the insulating materials. Thus, the development and utilization of Tree Retardant Cross-Linked Polyethylene (TR-XLPE) based cables have recently been given great attention to overcome the treeing issues. TR-XLPE cables use low-density polyethylene compounds suppressing the formation of water trees while retaining excellent electrical,...
-
The effect of fishing basin construction on the behaviour of a footbrdge over the port channel
PublikacjaThe paper analyses possible causes of failure of the rotating footbridge over the Ustka port channel. In July, 2015, strange behaviour of this object was observed in the form of excessive vibrations of bridge platform suspension rods, with the accompanying acoustic effects. A preliminary geotechnical analysis has revealed that this destructive effect was caused by the nearby construction works, namely construction of a fishing...
-
DYNAMIC ANALYSIS OF HISTORIC RAILWAY BRIDGES IN POLAND IN THE CONTEXT OF ADJUSTING THEM TO PENDOLINO TRAINS
PublikacjaThe article presents the dynamic analysis of the historic railway bridge in Tczew as an example of the usefulness of such type of bridge for high-speed trains. The model of the bridge and the simulation of rolling stock passage was performed in SOFISTIK program. The scope of work includes experimental studies, the solution of the problem concerning the correct solution features dynamic model takes into account the dependencies...
-
Some kind of joints in composite polymer bridges
PublikacjaContemporary, polymer composites bridge structures are of two types: truss or arch structures(with many joints along the length) and beam structures with limited number of joints. Both of them have special types of composite polymer decks. An ideal solution is to join advantages of two types of structuresdescribed below and create long span FRP beam bridge structure system using joints along the length. Theproblem is to find the...
-
Krzysztof Wilde prof. dr hab. inż.
OsobyKrzysztof Wilde (ur. 11 I 1966 r. w Gdańsku) – specjalista z zakresu mostownictwa, mechaniki budowli, diagnostyki i geodezyjnego monitoringu konstrukcji inżynierskich. Prowadził badania ukierunkowane na opracowanie systemów redukcji drgań obiektów mostowych wywołanych działaniem wiatru i trzęsieniami ziemi. Prowadzi badania naukowe i prace rozwojowe związane z implementacją urządzeń i technologii diagnostyki nieniszczącej w obiektach...
-
The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables
PublikacjaThis paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublikacjaIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Modern GFRP Composite Footbridges
PublikacjaApplication of GFRP composites in civil engineering is still not large but already noticeable. Advantages of this material, such as: low volume weight, relatively high stiffness and strength, well fatigue resistance, easiness in shaping, high material damping and high environmental resistance, make it attractive for bridge and in particular foot-bridge designers. It is estimated that nowadays in the world there are realized hundreds...
-
Wielopoziomowy przekształtnik trakcyjny SiC z izolacją od sieci 3kV DC realizowaną za pomocą transformatorów 30kHz do napędów EZT
PublikacjaW referacie przedstawiono wielopoziomowy izolowany kaskadowy przekształtnik DC-AC z tranzystorami SiC MOSFET 1,2kV, przeznaczony do napędów elektrycznych zespołów trakcyjnych (EZT). Zaproponowana konstrukcja przekształtnika, przeznaczonego do pracy przy zasilaniu z sieci trakcyjnej 3kV DC, spełnia założenia energoelektronicznego transformatora trakcyjnego (z ang. Power Electronic Traction Transformer). Budowa modułowa z niskonapięciowych...
-
DYNAMIC ANALYSIS OF THE RAILWAY BRIDGES IN POLAND WITH REGARDS TO HIGH-SPEED TRAINS PASSAGE ADJUSTMENT
PublikacjaThe dynamic analysis of the railway bridge in Tczew was carried out in the article as an example of such bridges adaptation suitability to handle high-speed trains. Calculations of railway bridges are greatly complicated and labor-consuming. The bridge model and a rolling stock passage simulation were developed in the SOFISTIK software. Three types of elements were used for the correct mapping of the structure in the calculation...
-
Structural Health Monitoring System for Suspension Footbridge
PublikacjaThe article presents the structural health monitoring (SHM) system installed in a footbridge in Radom. The main reason for the need for fitting of such a system was failed acceptance tests of the bridge. While under a dynamic load consisting of a group of 12 pedestrians jumping on the bridge, the bridge developed vibration during which acceleration of the deck of up to 4.5 m/s2 was recorded. Such behavior of the footbridge causes...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Design and evaluation of a base module of active power electronic transformer
PublikacjaThis paper presents an active power electronic transformer (APET) based on modular structure. The proposed three phase APET consists of at least three base modules (BM). The input/output stage of the BM is based on half-bridge sub modules. The isolation stage includes a medium frequency transformer and is realized as a dual half-bridge. The paper describes construction process and explains the control strategy. The theoretical...
-
Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view
PublikacjaPower cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...
-
Composite sandwich footbridge - measured dynamic response vs. FEA
PublikacjaThe paper describes a process of in situ dynamic tests of a composite sandwich footbridge before its accepta-tion for exploitation in real traffic conditions. It is only a part of a big research task that includes design, manufacture and introduce practical application of the bridge. The in situ measured natural modes and fre-quencies are compared with numerically determined ones. Finite element analysis is established to estimate...
-
Ampacity of power cables exposed to solar radiation – recommendations of standards vs. CFD simulations
PublikacjaThe aim of the paper is to evaluate the ampacity of a low-voltage single power cable according to: 1) recommendations of the standard IEC 60287, 2) a Computational Fluid Dynamics method, implemented in Ansys software; and comparison of the results obtained for these two cases. Moreover, limitations of recommendations of the above mentioned standard are indicated.
-
Arch bridges under test loadings
PublikacjaThis paper illustrates experience in arch bridges test loadings of the research team of Department of Structural Mechanics and Bridge Structures from the Gdansk University of Technology. The presented calculations results constist the analysis of spatial construction schemes made using the finite elements method (FEM) and its comparison to the field studies. Arch bridges with the longest spans, visualisation of the computational...
-
Single-phase power electronics transformer with active functions for smart grid
PublikacjaThis paper presents the control of one cell of a modular single-phase power electronics transformer with active functions for meeting the smart grid concept. In this way, the converter could be used not only as a conventional transformer but also for grid such as reactive power, harmonic elimination and energy storage. The topology of the cell is composed by a bidirectional converter with three stages: a half bridge in the input...
-
Short and Long Term Measurements in Assessment of FRP Composite Footbridge Behavior
PublikacjaThe paper presents application of different sensors for the purpose of short and long term measurements, as well as a structural health monitoring (SHM) system to assess the behavior of a novel fiber reinforced plastics (FRP) composite footbridge. The aim is to present a thorough and concise description of these sensors networks and results gathered with their aid during in situ measurement of strains, displacements, and vibrations,...
-
Load test of new European record holder in span length among extradosed type bridges
PublikacjaThe article presents acceptance load tests of a newly built extradosed MS-3 bridge located along the national road DK-16 near Ostróda (Poland). The structure features significant dimension in European reference scale. It is a new record holder in span length regarding this distinct bridge category. Its length ranges 206 m. Static and dynamic load tests were performed here. The program was extended by entire structural laser scanning...
-
Przemysław Kalitowski dr inż.
OsobyPrzemyslaw Kalitowski (born 26 July 1991) currently works at the Gdansk University of Technology in Gdansk, Poland. He acts as the Professor's Assistant at the Department of Rail Transportation and Bridges. In 2015 he started PhD studies at the Department of Rail Transportation and Bridges. He has over 4 years experience in static and dynamic analysis of structures - primarily with FEM programs. The scope of analysis are mainly...
-
Improving the procedure of probabilistic load testing design of typical bridges based on structural response similarities
PublikacjaThis paper concerns load testing of typical bridge structures performed prior to operation. In-situ tests of a two-span post-tensioned bridge loaded with three vehicles of 38-ton mass each formed the input of this study. On the basis of the results of these measurements, an advanced FEM model of the structure was developed for which the sensitivity analysis was performed for chosen uncertainty sources. Three uncorrelated random...
-
Parametric analysis of Istanbul's Ring Road viaduct for three levels of seismic load
PublikacjaThe paper presents a numerical analysis of the Istanbul's ring road viaduct that is currently under construction within the Northern Marmara Highway project. The structure, due to its location on seismic prone areas is exposed to seismic loads of different magnitude and different return periods. The study is fo-cused on concrete bridge supports that are design to work in nonlinear range. The study, conducted in SOFISTIK environment,...
-
Earthquake-Induced Structural Pounding
PublikacjaEarthquake-induced structural pounding between insufficiently separated build-ings, or bridge segments, has been repeatedly observed during ground motions. The reports after earthquakes indicate that it may lead to some local damage in the case of moderate seismic events or may result in considerable destruction or even collapse of colliding structures during severe ground motions. Pounding in build-ings is usually caused by the...
-
Application of probabilistic tools to extend load test design of bridges prior to opening
PublikacjaLoad tests of bridges are widely performed in a large number of countries. Deterministic comparison of measurement results to the theoretical, FEM (finite element method)-based outcomes with possible further calibration is mostly applied. Sometimes, the data collected in the tests are also used to calibrate the reliability factors of bridge structures or their components. This work proposes to complement the stage of the load test...
-
Impact of thermal backfill parameters on current-carrying capacity of power cables installed in the ground
PublikacjaProper design of power installations with the participation of power cables buried in homogeneous and thermally well-conductive ground does not constitute a major problem. The situation changes when the ground is non-homogeneous and thermally low-conductive. In such a situation, a thermal backfill near the cables is commonly used. The optimization of thermal backfill parameters to achieve the highest possible current-carrying capacity...
-
Design and numerical testing of 5-box gfrp shell footbridge
PublikacjaThe paper formulates new design conditions for composite footbridges, taking into account the material and structural specificity of these objects, i.e. the strength condition, the serviceability condition and the frequency condition. A GFRP composite footbridge labelled with CFB2 code has been designed, with the original superstructure in the form of an opened-closed 5-box girder. The foot and cycle track bridge is simply supported,...
-
OCENA WŁAŚCIWOŚCI STALI STOSOWANEJ W STARYCH OBIEKTACH KOLEJOWYCH
PublikacjaThe scope of the paper is to give an introduction to the assessment subject matter of steel properties used in old railway bridges. The mechanical and chemical properties of construction steel extracted from old steel bridges are generally investigated by tensile tests, impact tests through the Charpy pendulum impact V-notch, and an optical emission spectrometer. Besides descriptions of the tests, the chosen chemical and mechanical...
-
Parametric analysis of Istanbul's Ring Road viaduct for three levels of seismic load
PublikacjaThe paper presents a parametric analysis of the Istanbul's ring road viaduct that is currently under construction within the Northern Marmara Highway project. The structure, due to its location on seismic prone areas is exposed to seismic loads of different strengths and different return periods. The study is focused on concrete bridge supports that are design to work in nonlinear range. The parametric study, conducted in MATLAB...
-
KOMPOZYTOWY MOST PIESZO - ROWEROWY
PublikacjaPaper presents the composite foot and cycle bridge developed in FOBRIDGE grant cofinanced by The National Centre for Research and Development and realized by consortium of Gdansk University of Technology (leader), Military University of Technology in Warsaw and ROMA Sp. z o.o. in Toruń. The purpose of the grant was to design a shell type single span foot and cycle bridge made of composite materials, with the assumption of manufacturing...