Filtry
wszystkich: 3911
-
Katalog
- Publikacje 1464 wyników po odfiltrowaniu
- Czasopisma 1 wyników po odfiltrowaniu
- Osoby 76 wyników po odfiltrowaniu
- Wynalazki 8 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Laboratoria 5 wyników po odfiltrowaniu
- Zespoły Badawcze 6 wyników po odfiltrowaniu
- Aparatura Badawcza 38 wyników po odfiltrowaniu
- Kursy Online 288 wyników po odfiltrowaniu
- Wydarzenia 9 wyników po odfiltrowaniu
- Dane Badawcze 2015 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: 1,3,5-triazines
-
Crystal and electronic structures of Ni(II) silanethiolates containing flexible diamine ligands
PublikacjaFive nickel(II) complexes containing aliphatic diamines and tri-tert-butoxysilanethiolate ligand have been synthesized for the purpose of studying their structural, spectral (IR, UV–Vis, HF EPR) and thermal properties. Complexes (1)–(5) have been prepared in high yield by reactions of [Ni{SSi(OtBu)3}2(NH3)(H2O)] with 1.3-propanediamine (L1), 1,6-hexanediamine (L2), or 1,7-heptanediamine (L3). The X-ray structures were determined...
-
Marcin Perzanowski dr inż.
OsobyHello, I work in the Department of Magnatic Materials and Nanostructures in the Institute of Nuclear Physics Polish Academy of Sciences in Kraków, Poland. My current research is focused on: (1) exchange bias in multilayers and nanostructures, (2) supermagnetic effects in low-dimensional materials, (3) perpendicular magnetic anisotropy in thin films and nanostructures. Collaborations, comments, and suggestions are welcomed! If...
-
Zmodyfikowana metoda prognozowania rezultatów nadzorowania drgań narzędzie--przedmiot obrabiany. W: Projektowanie mechatroniczne. Zagadnienia wybrane. Praca zbiorowa pod red. T. Uhla. Kraków: Kated. Robotyki i Dynam. Masz.AGH**2003 s. 125-134, 3 rys. 1 tab. bibliogr. 6 poz.
PublikacjaW pracy przedstawiono zmodyfikowaną metodę prognozowania rezultatów nadzoro-wania drgań narzędzie-przedmiot obrabiany za pomocą sterowanej programowo prędkości obrotowej wrzeciona. Istotą modyfikacji jest uwzględnienie w mode-lu złożoności geometrycznej narzędzia oraz efektu rozproszenia energii pro-cesu skrawania. Podano opis dynamiki skrawania niestacjonarnego modelu obli-czeniowego, oraz sposobu nadzorowania. Zamieszczono...
-
Non linear identification of underwater vehicles. W: [CD-ROM] Conference Proceedings. The 29th Israel Conference on Mechanical Engineering. May 12-13, 2003 Haifa, Israel. Haifa: Technion - Israel Inst. Technol.**2003[B8] s. 1-8, 5 rys. bibliogr. 7 poz. Nieliniowa identyfikacja pojazdów podwodnych.
PublikacjaArtykuł dotyczy identyfikacji nieliniowych modeli pojazdów podwodnych o wie-lu zmiennych. Zaproponowana metoda działa w obszarze czasu rzeczywistego imoże być stosowana do nieliniowych modeli, które są liniowe w części doty-czącej nieznanego wektora parametrów. W celu poradzenia sobie z parametramizmieniającymi się w czasie, zastosowano rekursyjną wersję algorytmu identy-fikacji. Po krótkim opisie matematycznych podstaw...
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [625073001062971]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [6250730010622841]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [6250730010626451]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [6250730010628361]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [6250730010626171]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [6250730010623141]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [625073001062751]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [6250730010629861]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [6250730010628161]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [6250730010626961]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Optimized Hydrodynamic Vortex Separator
PublikacjaThe invention discloses an optimized hydrodynamic vortex separator which comprises an outer cylinder (1), an inner cylinder (2), a sludge hopper (3), an inlet (4), an outlet (5) and a conical structure (7), wherein the outer cylinder (1) is the boundary of the outer wall of the separator; wherein the inner cylinder (2) is arranged in an inner cavity of the outer cylinder (1); the sludge hopper (3)is taken as the bottom of the...
-
W. Zbirohowski-Kościa WZIE II st., 3 i 4 semestralne, 1 sem 21/22l
Kursy Online -
Obróbka skrawaniem: W/L; ZiIP, 1 stopień, 3 semestr (M:31808W0): Zima 2022/2023
Kursy Online -
WILiŚ - Tr. sem.1 ćw. gr 2, 3 - e-testy - Matematyka 2023/2024 (M.Suchecka)
Kursy Online -
Lobular carcinoma, NOS - Female, 54 - Tissue image [10100730045403091]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma, NOS - Female, 54 - Tissue image [10100730045401901]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013388061]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013387931]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013387181]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma, NOS - Female, 54 - Tissue image [10100730045402001]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma, NOS - Female, 54 - Tissue image [10100730045407371]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma, NOS - Female, 54 - Tissue image [1010073004540291]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013383071]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [710073001338301]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013382981]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma, NOS - Female, 54 - Tissue image [10100730045404071]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma, NOS - Female, 54 - Tissue image [10100730045406911]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma, NOS - Female, 54 - Tissue image [10100730045407711]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Stereoselective Alkylation of Indole with 5-Arylidene-Meldrum’s Acids in the Presence of Organocatalysts
PublikacjaBackground: Indole motif is frequently present in biologically active compounds. Enantiomerically pure or enriched 2,2-dimethyl-5-(aryl(1H-indol-3-yl)methyl)-1,3-dioxane-4,6-diones can be considered as a convenient starting point for the synthesis of a indole ring fused with cyclic ketones with biological activity. Preparation of chiral 2,2-dimethyl-5-(aryl(1H-indol-3-yl)methyl)-1,3-dioxane- 4,6-diones requires the reaction of...
-
Invasive breast carcinoma of no special type - Female, 53 - Tissue image [625073001062761]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fluorescent analogs of trypsin inhibitor SFTI-1 isolated from sunflower seeds-synthesis and applications
PublikacjaThis article describes the synthesis and enzymatic study of newly synthesized analogs of trypsin inhibitors SFTI-1 that were fluorescent labeled on their N-terminal amino groups. Two fluorescent derivatives of benzoxazole (3-[2-(4-diphenylaminophenyl) benzoxazol-5-yl]-L-alanine[(4NPh(2)) Ph] Box-Ala and 3-[2-(2', 4', 5'-trimethoxyphenyl) benzoxazol-5-yl]-l-alanine-[2,4,5-(OMe)3Ph] Box-Ala) were used as efficient fluorescent labels....
-
Mantle cell lymphoma - Male, 70 - Tissue image [7120837250927171]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013385471]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013384901]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013385451]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013385131]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013384711]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013386051]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013389151]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013387211]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mantle cell lymphoma - Male, 70 - Tissue image [7100730013386771]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lower rim substituted p-tert-butylcalix[4]arene; Part 14. Synthesis, structures and binding studies of calix[4]arene thioamides
PublikacjaA number of p-tert-butylcalix[4]arene thioamides were synthesized and characterized by 1H-NMR and elemental analysis. Compounds 1-5 are O-substituted derivatives with -CH2-C(=S)-N-X groups, where NX = morpholidyl, NEt2, NHC2H4Ph, NHCH2Ph and NHEt,respectively. The X-ray structures of the ligands 1, 3, 5 and of the complex 3Pb(ClO4)2, (compound 6), are presented and their slightly distorted cone conformation is established. The...
-
Probing the Magnetic Anisotropy of Co(II) Complexes Featuring Redox-Active Ligands
PublikacjaCoordination complexes that possess large magnetic anisotropy (otherwise known as zero-field splitting, ZFS) have possible applications in the field of magnetic materials, including single molecule magnets (SMMs). Previous studies have explored the role of coordination number and geometry in controlling the magnetic anisotropy and SMM behavior of high-spin (S = 3/2) Co(II) complexes. Building upon these efforts, the present work...
-
Roland Wesolowski Ph.D.
Osoby -
Optimization of Chemical Functionalities of Indole-2-carboxamides To Improve Allosteric Parameters for the Cannabinoid Receptor 1 (CB1)
Publikacja5-Chloro-3-ethyl-N-(4-(piperidin-1-yl)phenethyl)-1H-indole-2-carboxamide (1; ORG27569) is a prototypical allosteric modulator for the cannabinoid type 1 receptor (CB1). Here, we reveal key structural requirements of indole-2-carboxamides for allosteric modulation of CB1: a critical chain length at the C3-position, an electron withdrawing group at the C5-position, the length of the linker between the amide bond and the phenyl ring...
-
Witold Zbirohowski-Kościa, WZiE, 3 i 4 semestralne studia, II st, 1 sem, 20/21l
Kursy Online