Filtry
wszystkich: 14
Wyniki wyszukiwania dla: COLIFORMS
-
Isolation of multidrug resistant coliforms and their bacteriophages from swine slurry
Publikacja -
Identification and antimicrobial susceptibility of fecal coliforms isolated from surface water
Publikacjaof 274 fecal coliforms isolated from two watercourses influencing the costal water quality of the gdańsk and the puck bay, 265 were identified as escherichia coli. the remained strains belonged to: acinetobacter spp. (n=1), enterobacter spp. (n=3), klebsiella spp. (n=4) and shigella spp. (n=1). the susceptibility of 222 e. coli was tested against 19 antimicrobial agents: aminoglycosides, carbapenems, cephalosporines, folate antagonists,...
-
A global multinational survey of cefotaxime-resistant coliforms in urban wastewater treatment plants
PublikacjaThe World Health Organization Global Action Plan recommends integrated surveillance programs as crucial strategies for monitoring antibiotic resistance. Although several national surveillance programs are in place for clinical and veterinary settings, no such schemes exist for monitoring antibiotic-resistant bacteria in the environment. In this transnational study, we developed, validated, and tested a low-cost surveillance and...
-
Diversity of fecal coliforms and their antimicrobial resistance patterns in wastewater treatment model plant.
PublikacjaThe occurrence of resistance patterns among wastewater fecal coliforms was determined in the study. Susceptibility of the isolates was tested against 19 antimicrobial agents: aminoglycosides, aztreonam, carbapenems, cephalosporines, b-lactam/b-lactamase inhibitors, penicillines, tetracycline, trimethoprim/sulfamethoxazole, and fluoroquinolones. Additionally the removal of resistant isolates was evaluated in the laboratory-scale...
-
Diversity of fecal coliforms and their antimicrobial resistance patterns in wastewater treatment model plant
Publikacja -
Presence and distribution of antibiotic-resistant bacteria in multiphase activated sludge system
PublikacjaIn total 237 isolates of coliforms (113 strains) and enterococci (124 stains) from influent, mixed liquor in bioreactor and effluent of wastewater treatment plant (WWTP), were isolated on selective media and examined for antibiotic resistance. From 50 to 80% of the coliform strains isolated from the raw and treated sewage were resistant against ceftazidime CAZ, cefuroxim CXM, cefalotin KF and against amoxicillin AML, and only below...
-
The influence of moderate pressure and subzero temperature on the shelf life of minced cod, salmon, pork and beef meat
PublikacjaThe effect of moderate pressure at subzero temperature on natural microflora of minced cod, salmony, pork and beef meat was studied. Pressure of 193 MPa at –20 °C caused reduction of total bacterial count in pork and beef meat by 1.1 and 0.6 log cycles, respectively, and by about 1.5 log cycles in fish meat. Under these conditions the psychrophilic and psychrotophic bacteria were below the detection limit (<10CFU/g of sample) in...
-
Soil and groundwater fecal contamination as a result of sewage sludge land application.
PublikacjaThe release of sludge-born bacteria and their further transport in subsurface was studied. The migration of bacteria was investigated in column experiments which were carried out under the conditions corresponding to naturally occurring extreme rainfall. Coal fly ash as well as coarse and medium grained sand, which properties are similar to the soils present in degraded areas, were used as column beds. Sewage sludge was applied...
-
Microbial and chemical quality assessment of the small rivers entering the South Baltic. Part II: Case study on the watercourses in the Puck Bay catchment area
PublikacjaDue to its location, Puck Bay is an area particularly vulnerable to pollution of anthropogenic origin. The aim of the study was to assess the water quality of small watercourses entering the inner part of Puck Bay. The paper presents the results of chemical and microbiological analyses of 10 rivers and canals at their estuaries located on the western shore of the internal Puck Bay. The following environmental parameters were analyzed:...
-
Removal of indicator bacteria from treated wastewater using physical and chemical methods. Pilot plant study.
PublikacjaEven after highly efficient biological processes the effluents from wastewater treatment plants may contain significant number of fecal bacteria, from 104 to 106 CFU/100 mL. Since no standards are set on the bacteriological quality of treated wastewater in Poland the elimination of bacterial contaminants is not a priority in wastewater treatment policy. Thus microbiological hazards become particularly significant in the situation...
-
Microbial and chemical quality assessment of the small rivers entering the South Baltic. Part I: Case study on the watercourses in the Baltic Sea catchment area
PublikacjaThe area of the Coastal Landscape Park (CLP) due to its location is extremely attractive touristic area. In the summer season, a significant increase in population density is observed, which influences surface water quality. Large numbers of tourists generate an increased amount of municipal wastewater, being treated in local treatment plants and discharged into rivers and streams. The paper presents preliminary research from summer...
-
Drinking water safety evaluation in the selected sub-Saharan African countries: A case study of Madagascar, Uganda and Rwanda
PublikacjaIn the sub-Saharan region of Africa, access to safe drinking water remains limited in many countries. This study provides an overview of the quality of surface water and groundwater in rural and peri-urban areas of Madagascar, Uganda, and Rwanda. Selected physico-chemical parameters, inorganic species (including inorganic ions), and organic pollution indicators, such as total organic carbon, non-ionic surfactants, cationic surfactants, anionic...
-
Antimicrobial resistance of fecal indicators in muncipal wastewater treatment plant
PublikacjaAntimicrobial resistance of fecal coliforms (n = 153) and enterococci (n = 199) isolates was investigated in municipal wastewater treatment plant (WWTP) based on activated sludge system. The number of fecal indicators (in influent and effluent as well as in the aeration chamber and in return activated sludge mixture) was determined using selective media. Susceptibility of selected strains was tested against 19 (aminoglycosides,...
-
Ultrafiltration Process in Disinfection and Advanced Treatment of Tertiary Treated Wastewater
PublikacjaThe paper presents the results of research on the use of ultrafiltration, using membranes of 200 and 400 kDa separation, for disinfection of municipal treated wastewater. The research was conducted on a fractional technical scale using real municipal treated wastewater from two large wastewater treatment plants treating most of the wastewater over the one-million polycentric Gdańsk agglomeration (1.2 million inhabitants). UF 200...