Filtry
wszystkich: 10042
-
Katalog
- Publikacje 6989 wyników po odfiltrowaniu
- Czasopisma 492 wyników po odfiltrowaniu
- Konferencje 245 wyników po odfiltrowaniu
- Osoby 312 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 20 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 3 wyników po odfiltrowaniu
- Kursy Online 219 wyników po odfiltrowaniu
- Wydarzenia 8 wyników po odfiltrowaniu
- Dane Badawcze 1752 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: LOW VOLTAGE SYSTEMS
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublikacjaThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Voltage Harmonics Measuring Issues in Medium Voltage Systems
PublikacjaW rozdziale przedstawiono zagadnienia związane z dokładnością pomiarów zniekształceń harmonicznych napięcia z wykorzystaniem przekładników napięciowych w sieciach średnich napięć.
-
Low voltage photovoltaic power system
PublikacjaThe use of photovoltaics is growing rapidly in the industry as well as households. Therefore, educating the public will help them understand solar cell technology, which is becoming more common in everyday life. This paper proposes a demonstrational set-up of photovoltaic panel for the purpose of science education. It was used in numerous outreach activities such as science fairs. Moreover, it proved to be a great tool for education...
-
Improving voltage levels in low-voltage networks with distributed generation – case study
PublikacjaThe use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublikacjaRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Multipulse inverter structures with low voltage distortion
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Quality assessment of low voltage surge arresters
PublikacjaUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
A High-Efficient Low-Voltage Rectifier for CMOS Technology
PublikacjaA new configuration of rectifier suiting CMOS technology is presented. The rectifier consists of only two nchannel MOS transistors, two capacitors and two resistors; for this reason it is very favourable in manufacturing in CMOS technology. With these features the rectifier is easy to design and cheap in production. Despite its simplicity, the rectifier has relatively good characteristics, the voltage and power efficiency, and...
-
Low harmonic multipulse voltage converters using coupled reactors
PublikacjaThis paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublikacjaAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Fractional-order Systems and Synchronous Generator Voltage Regulator
PublikacjaModern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublikacjaLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Dynamic current-voltage characteristics of dielectrics with extremely low heat conductivity
PublikacjaZaprezentowano teoretyczny opis metody dynamicznych charakterystyk prądowo-napięciowych w przypadku znacznego gradientu temperatury w ciałach stałych o przewodności jonowej. Otrzymano rozwiązania równania transportu oraz równania charakterystyk, odnoszące się do ruchu cienkiej warstwy nośników ostałej grubości oraz warstwy rozszerzającej się. Podano także przybliżone wyrażenia opisujące czas przelotu nośników. Wyniki zweryfikowano...
-
THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS
PublikacjaThe paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.
-
Output-capacitorless low-dropout regulator using a cascoded flipped voltage follower
PublikacjaPrzedstawiono udoskonaloną konfigurację wtórnika napięciowego w odwróconej konfiguracji oraz jej zastosowanie w regulatorze o małym spadku napięcia. W pracy przedstawiono teoretyczną analizę podstawowych parametrów wtórnika oraz regulatora napięcia. Ponadto przedstawiono wyniki pomiarów parametrów prototypowego układu scalonego wykonanego z użyciem technologii CMOS 0.35 um. Uzyskane wyniki porównano z rezultatami uzyskanymi w innych...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...