Wyniki wyszukiwania dla: MECHANICS IN MEDICINE MECHANICAL PROPERTIES HERNIA MANAGEMENT - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: MECHANICS IN MEDICINE MECHANICAL PROPERTIES HERNIA MANAGEMENT

Wyniki wyszukiwania dla: MECHANICS IN MEDICINE MECHANICAL PROPERTIES HERNIA MANAGEMENT

  • Towards Understanding of Mechanics of Hernia Managed by Synthetic Mesh in Laparoscopic Operation: A Single Case Study

    In this paper a research towards understanding of mechanics of ventral hernia operated with the use of Physiomesh Open image in new window implant and SecureStrap Open image in new window staples is described. Experimental and numerical studies are conducted for that purpose. Experimental works cover uni-axial tension tests of the implant samples and of the implant-staples-tissue system. Also experiments on implant-staples-tissue...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Constitutive Modelling of Knitted Abdominal Implants in Numerical Simulations of Repaired Hernia Mechanics

    The paper presents a numerical approach to describe mechanical behavior of anisotropic textile material, which is a selected abdominal prosthesis. Two constitutive nonlinear concepts are compared. In the first one the material is considered composed from two families of threads (dense net model) and in the second one the material is homogeneous but anisotropic (as proposed by Gassel, Ogden, Holzapfel). Parameters of both models...

    Pełny tekst do pobrania w portalu

  • Biomechanical causes for failure of the Physiomesh/Securestrap system

    Publikacja

    - Scientific Reports - Rok 2023

    This study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh...

    Pełny tekst do pobrania w portalu

  • Modelling of Abdominal Wall Under Uncertainty of Material Properties

    Publikacja

    - Rok 2020

    The paper concerns abdominal wall modelling. The accurate prediction and simulation of abdominal wall mechanics are important in the context of optimization of ventral hernia repair. The shell Finite Element model is considered, as the one which can be used in patient-specific approach due to relatively easy geometry generation. However, there are uncertainties in this issue, e.g. related to mechanical properties since the properties...

    Pełny tekst do pobrania w portalu

  • Wiktoria Wojnicz dr hab. inż.

    DSc in Mechanics (in the field of Biomechanics)  - Lodz Univeristy of Technology, 2019  PhD in Mechanics (in the field of Biomechanics)  - Lodz Univeristy of Technology, 2009 (with distinction)   Publikacje z listy MNiSW (2009 - ) Wojnicz W., Wittbrodt E., Analysis of muscles' behaviour. Part I. The computational model of muscle. Acta of Bioengineering and Biomechanics, Vol. 11, No.4, 2009, p. 15-21 Wojnicz W., Wittbrodt E., Analysis...

  • Mechanical properties of mosquito nets in the context of hernia repair

    The paper deals with issue of applying mosquito nets as implants in hernia repair, which have already been used in resource-poor developing countries. Uniaxial tensile tests have been conducted on polyester mosquito meshes in two orthogonal directions. Non-linear elastic constitutive laws parameters have been identified to be applied in dense net material models. Mechanical performance of tested mosquito nets has been compared...

    Pełny tekst do pobrania w portalu

  • Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair

    Publikacja

    Even though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...

    Pełny tekst do pobrania w portalu

  • Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.

    Publikacja

    - SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES - Rok 2023

    repairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Mechanics and Mechanical Engineering

    Czasopisma

    ISSN: 1428-1511 , eISSN: 2354-0192

  • Mechanical behaviour of knit synthetic mesh used in hernia surgery

    Purpose: There is a discussion in literature concerning mechanical properties and modelling of surgical meshes. An important feature of elastic modulus dependency on load history is taken into account in this paper, as implants are subjected to variable loading during human activity. The example of DynaMesh®-IPOM surgical implant is studied. Methods: The analysis is based on failure tension tests and cyclic loading and unloading...

    Pełny tekst do pobrania w portalu

  • Mohammad Malikan dr inż.

    Mohammad Malikan studied Ph.D. at the Department of Mechanics of Materials and Structures at the Gdańsk University of Technology. He was the first person who graduated in the new form of the doctoral education system of Poland (Doctoral School). He has worked as a mechanical engineer and designer for several years in CAD/CAE fields in various industries, such as feed production lines, machinery, elevator, oil, etc. His main research...

  • Application and mechanical properties of aluminium alloys

    Publikacja

    The paper presents a short survey of the application and mechanical properties of aluminium alloys. This area of scientific research is still developing, the authors restricted it to about 30 papers. Numerical simulations of the aluminium bracket are also investigated. The authors propose a solution to increase the load capacity of aluminium brackets with application of the additional cover plates. This study is proposed as an...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Mechanical compatibility of implants used in hernia repair with abdominal wall

    The paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Mechanical Modelling of Human Fascia in the Problem of Ventral Hernia Repair

    Publikacja

    - Rok 2010

    Praca dotyczy badań doświadczalnych tkanki ludzkiej oraz symulacji numerycznej zachowania tej tkanki. Na podstawie eksperymentu dokonuje się identyfikacji modelu materiałowego tkanki a następnie w celu wweryfikacji przeprowadza się symulacje numeryczną zachowania modelowanej struktury. Celem badań jest uzyskanie informacji przydatnych podczas leczenia przepuklin brzusznych u ludzi.

  • Mechanical, thermo-mechanical properties of epoxy/glass composites with submicron particles

    Publikacja

    - Rok 2013

    In this research the influence of submicron zinc oxide and silicon dioxide particles on mechanical, thermo-mechanical properties of epoxy matrix composites reinforced with glass fibres was investigated. Composites were fabricated using hand lay-up method. Materials contained 39-41 wt.% of glass fibres. The bending tests, dynamic mechanical analysis and tribological tests were performed on each group of composites and also for...

  • Influence of steam drying process on wood mechanical properties

    Results of influence of gas-steam mixture drying process on mechanical properties of material are presented. Wood species, namely oak (Quercus L.), beech (Fagus L.), pine (Pinus L.) and spruce (Picea K.) from the northern part of Pomerania region in Poland, were subject of air-steam mixture drying process in a laboratory kiln especially arranged for that reason. Measurements of the global coefficient of elasticity and bending strength...

  • Dynamics of mechanical model of implant-tissue system in ventral hernia repair

    The paper deals with a finite element modelling of implants in the problem of ventral hernia repair. The synthetic mesh implanted in the abdomen during surgery is here modelled as a membrane structure. Thesystem undergoes the internal abdominal pressure that occurs during the postoperative cough, the load identified in the literature as the main cause of the connection failure and hernia recurrence. The model can be used to estimate...

    Pełny tekst do pobrania w portalu

  • Mechanical Properties of Human Stomach Tissue

    Publikacja

    - Rok 2022

    The dataset entitled Determination of mechanical properties of human stomach tissues subjected to uniaxial stretching contains: the length of the sample as a function of the corresponding load (tensile force) and the initial values of the average width and average thickness of the sample. All tests were conducted in a self-developed tensile test machine: PG TissueTester. The dataset allows the coefficients of various models of...

    Pełny tekst do pobrania w portalu

  • Experimental tests for the determination of mechanical properties of PVC foil

    Publikacja

    - Rok 2016

    The paper presents an application of the PVC film in civil engineering. Mechanical behaviour of the PVC film applied for suspended ceilings, in the form of a stretch ceiling is investigated under uniaxial and biaxial tensile tests. The study is focused on the determination of mechanical properties from experimental data (uniaxial and biaxial tensile tests). The uniaxial cyclic tests are performed in order to observe a variation...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • CHARACTERIZATION STUDY ON MECHANICAL PROPERTIES OF POLYESTER COATED FABRIC

    The scope of the paper is to determine the mechanical properties of the Precontraint 1302 polyester coated fabric under uniaxial and biaxial tensile tests. The results are compared for Precontraint 1302 fabric and other types of coated fabrics. The author applied an orthotropic model and a dense net model to reflect the polyester coated fabric performance under uniaxial and biaxial tensile tests. Material parameters are specified...

    Pełny tekst do pobrania w portalu