Filtry
wszystkich: 228
Wyniki wyszukiwania dla: OCT
-
Monitoring of activities carried out as part of prototyping and implementation of the pilot project in the area of the "Polanki" market and its and its direct neighbourhood, in the Gdańsk-Oliwa district, step1; stage from October 2020 year.
Dane BadawczeThe data presents tabular monitoring lists (quantitative and qualitative documentation report in the form of tables) of activities carried out as part of prototyping and implementation of the pilot project in the area of the Polanki market and its immediate vicinity in the Gdańsk-Oliwa district in 2020 year - step 1, stage from July 2020. The monitoring...
-
A decade of Poland`s integrated Road Safety Programme - economic develop-ment vs. road unsafety. W: [CD-ROM]. Conference proceedings. SORIC´02. 2nd Safety on Road Internationaload International Conference. Kingdom of Bah- rain, 21-23 October 2002. Bahrain: CTRS Univ. Bahrain**2002 [8 s. 5 rys. bibliogr. 5 poz. 10 lat Krajowego Programu Bezpieczeństwa Ruchu Drogowego w Polsce - rozwój ekonomiczny a niebezpieczeństwo ruchu.
PublikacjaReferat zawiera analizę doświadczeń z dziesięciu lat pracy oraz wdrożeń Kra-jowego Programu Bezpieczeństwa Ruchu Drogowego GAMBIT. Przedstawia również analizę przyczyn gwałtownego spadku liczby- śmiertelnych ofiar wypadków dro-gowych w Polsce w roku 2001.
-
Hypertension types defined by clinic and ambulatory blood pressure in 14 143 patients referred to hypertension clinics worldwide. Data from the ARTEMIS study
Publikacja -
Analiza danych pomiarowych na potrzeby obrazowania optyczną tomografią koherentną
PublikacjaW rozdziale omówiono wybrane aspekty związane z analizą danych pomiarowych na potrzeby obrazowania metodą optycznej tomografii koherentnej. Przedstawiono podstawowe zależności umożliwiające obrazowanie tkanek na podstawie analizy promieniowania wstecznie rozproszonego, mierzonego przez systemy OCT pracujące w dziedzinie czasu (TD-OCT) lub w dziedzinie częstotliwości (FD-OCT). Pokazano, że wykorzystując zaawansowane przetwarzanie...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublikacjaCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems
PublikacjaSimulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all, the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason,...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublikacjaThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Advanced polarization sensitive analysis in optical coherence tomography
PublikacjaThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Latent fingerprint imaging by spectroscopic optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a non-contact and non-invasive optical method for evaluating semitransparent and scattering objects. Its unique features, such as non-destructive 3D measurements of tested objects with a fast scanning rate, make this technique interesting for latent fingerprint reading, which is the subject of this paper. So far, OCT has not found widespread use for reading fingerprints directly from surfaces...
-
Analiza stanu polaryzacji światła w układach optycznej tomografii koherentnej dla badań struktury materiałów optoelektronicznych i mikroelektronicznych
PublikacjaTematem rozprawy jest analiza stanu polaryzacji światła w optycznej tomografii koherentnej (OCT). Zagadnienie to dotyczy pomiaru stanu polaryzacji światła wsteczne odbitego lub wstecznie rozproszonego przez wewnętrzną strukturę badanego obiektu. Umożliwia to badanie właściwości optycznie anizotropowych materiałów, co pozwala na charakteryzację i rozróżnianie warstw tworzących wewnętrzną strukturę badanego obiektu oraz śledzenie...
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublikacjaOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
Zastosowanie czasowo-częstotliwościowej analizy sygnałów dla poprawy właściwości metrologicznych systemów optycznej tomografii koherentnej
PublikacjaOptyczna tomografia koherentna (OCT) jest metodą obrazowania wewnętrznej struktury obiektów rozpraszających promieniowanie optyczne. Metoda ta wykorzystuje interferometrię niskokoherentą do pomiaru czasu przelotu promieniowania wstecznie rozproszonego od elementów struktury obrazowanego obiektu z rozdzielczością w zakresie od jednego do kilkunastu mikrometrów. Rozprawa dotyczy dwóch rozszerzeń metody OCT. Pierwsze z nich – polaryzacyjna...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublikacjaNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Efficient signal processing in spectroscopic optical coherence tomography
PublikacjaSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
PublikacjaOCT to nowa metoda badania wewnętrznych struktur materiałów. Wśród wielu technik detekcji sygnału optycznego wykorzystywanych w OCT najpopularniejszą i najbardziej obiecującą jest OLCR (Opticla-Low Coherence Reflectomerty - reflektometria niskokoherentna). OLCR wykorzystuje szerokopasmowe źródła, których parametry, jak np.: charakterystyka widmowa, charakterystyka szumowa, determinują właściwości metrologiczne systemu OCT. W artykule...
-
Polarization sensitive optical coherence tomography system
PublikacjaW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Przemysłowe zastosowania optycznej tomografii koherentnej
PublikacjaOptyczna tomografia koherentna (OCT) jest nowoczesną techniką obrazowania wewnętrznej struktury obiektów rozpraszających światło. Główne zastosowania OCT należą do dziedziny obrazowania medycznego, jednak prowadzony jest także szereg badań nad przemysłowymi aplikacjami tej metody. Zaletą OCT jest możliwość tomograficznego obrazowania z rozdzielczością rzędu pojedynczych mikrometrów w sposób szybki i nieinwazyjny. W niniejszym artykule...
-
Joanna Wolszczak-Derlacz dr hab.
OsobyOd 2001 roku pracuję na Politechnice Gdańskiej, na Wydziale Zarządzania i Ekonomii, od 1 lipca 2016 na stanowisku profesora nadzwyczajnego. W 2006 r. uzyskałam stopień doktora nauk ekonomicznych, moja rozprawa została wyróżniona Nagrodą Prezesa Rady Ministrów. W latach 2007/2008 byłam beneficjentką stypendium podoktorskiego Max Weber Fellowship w Europejskim Instytucie Uniwersyteckim (European University Institute) we Florencji...
-
Dispersion compensation in optical coherence tomography
PublikacjaDyspersja wprowadzana przez system optycznej tomografii koherentnej (OCT) oraz badane obiekty powoduje zniekształcenia fazowe w zależności od długości fali widma promieniowania zastosowanego źródła optycznego. powoduje to rozmycie obrazów otrzymanych przekrojów badanych materiałów pogarszając właściwości metrologiczne systemu OCT. W artykule przedstawiono metody kompensacji dyspersji w systemie OCT oraz przedyskutowano ich właściwości.
-
Nanoparticles displacement analysis using optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits...