Accuracy Analysis of Determination the Vertical Displacements in Unstable Reference System
PublikacjaMeasurements of horizontal and vertical displacements are carried out mostly based on reference points identified as fixed. In surveying practice there may be some situations in which there is not possible to perform the measurements with reference to stable points or the difficulties in identification of points’ stability may arise. Accuracy analysis based on the covariance matrices have a special role in this process. In presented...
-
The Use of Free Adjustment and Msplit-Estimation for Determination of the Vertical Displacements in Unstable Reference System
PublikacjaThe problem of the determining of the displacements of engineering objects and their surroundings is the current and important issue in the field of engineering geodesy. Most control measurements are made in relation to reference points (stable points). On the other hand, sometimes it happens that it is not possible perform the measurements with reference to the stable points or identification of stable points is difficult. Therefore,...
-
Identification of Unstable Reference Points and Estimation of Displacements Using Squared Msplit Estimation
PublikacjaThe article presents a new version of the method for estimating parameters in a split functional model, which enables the determination of displacements of geodetic network points with constrained datum. The main aim of the study is to present theoretical foundations of Msplit CD estimation and its basic properties and possible applications. Particular attention was paid to the efficacy of the method in the context of geodetic...
-
DiSTFAG method robust to gross errors in monitoring displacements and strains in unstable reference systems
PublikacjaThe DiSTFA method (Displacements and Strains using Transformation and Free Adjustment) was presented in Kamiński (2009). The method has been developed for the determination of displacements and strains of engineering objects in unstable reference systems, as well as for examining the stability of reference points. The DiSTFAG (Gross errors) method presented in the paper is the extension of the DiSTFA method making it robust to...
-
Determination of vertical displacements by using the hydrostatic levelling systems with the variable location of the reference sensor,
PublikacjaAbstract: In this paper, the author proposed a new method for determination of vertical displacements with the use of hydrostatic levelling systems. The traditional method of hydrostatic levelling uses a rule in which a position of reference sensor is stable. This assumption was not adapted in the proposed method. Regarding the issue mentioned above, the reference sensor is treated in the same way as the others sensors that measure...
-
DETERMINATION OF VERTICAL DISPLACEMENTS IN RELATIVE MONITORING NETWORKS
PublikacjaThe problem of determining displacements of objects is an important and current issue, in particular in terms of operational safety. This is a requirement that covers geodetic, periodic control measurements in order to determine horizontal and vertical displacements. The paper is focused on the analysis of vertical displacements. Geodetic measurements and their interpretation allow to reduce the risk of possible structural catastrophes....
-
The Concept of Accuracy Analysis of the Vertical Displacements Gained from the Hydrostatic Levelling Systems’ Measurements
PublikacjaAbstract: Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the...
-
Reference FEM model for SHM system of cable-stayed bridge in Rzeszów
PublikacjaThe paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...
-
Devices for the production of reference gas mixtures
PublikacjaFor many years there has been growing demand for gaseous reference materials, which is connected with development in many fields of science and technology. As a result, new methodological and instrumental solutions appear that can be used for this purpose. Appropriate quality assurance/quality control (QA/QC) must be used to make sure that measurement data are a reliable source of information. Reference materials are a significant...
-
Investigation of the impact of ITRF2014/IGS14 on the positions of the reference stations in Europe
PublikacjaIn January 2017, the new realization of the International Terrestrial Reference Frame (ITRF) – ITRF2014, was released. Besides the higher accuracy and consistency of the new frame, an entirely new element – the post seismic deformation - was included. Moreover, the definition of the fundamental points has also been changed. All changes related to the new reference frame haveconsequences in the precise positioning using GNSS observations....
-
Reference Librarian
Czasopisma -
Development of the System Assurance Reference Model for Generating Modular Assurance Cases
PublikacjaAssurance cases are structured arguments used to demonstrate specific system properties such as safety or security. They are used in many industrial sectors including automotive, aviation and medical devices. Larger assurance cases are usually divided into modules to manage the complexity and distribute the work. Each of the modules is developed to address specific goals allocated to the specific objects i.e. components of the...
-
Corporate social responsibility in reference to environmental statements within EMAS system in small and medium enterprises
PublikacjaAccording to the corporate social responsibility concept, organisations should apply any mechanisms available supporting their business actions contributing i.e. to the improvement of natural environment. Among them is EMAS eco-management and audit scheme. The prove of its implementation is environmental statement and entering the organisation into a national EMAS register. The aim of the statement is informing the society and...
-
Electrocatalytic gas sensor with reference layer
PublikacjaIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
Electrocatalytic Gas Sensor with Reference Layer
PublikacjaThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Blurred quantum Darwinism across quantum reference frames
PublikacjaQuantum Darwinism describes objectivity of quantum systems via their correlations with their environment--information that hypothetical observers can recover by measuring the environments. However, observations are done with respect to a frame of reference. Here, we take the formalism of [Giacomini, Castro-Ruiz, & Brukner. Nat Commun 10, 494 (2019)], and consider the repercussions on objectivity when changing quantum reference...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublikacjaGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
The importance and availability of marine certified reference materials
PublikacjaTraceability and reliable results are the two pillars of analytical methods; certified reference materials (CRMs) meet this requirement. ISO 17034:2016 credentials provide brief information on general requirements for the competence of Reference Material Producers (RMPs). The different types of CRMs have been produced in recent years for chemical analysis in food, water, soil, and sediment matrices in recent years. This review...
-
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
PublikacjaIn this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations....
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublikacjaThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...