Wyniki wyszukiwania dla: chest perfusion computed tomography
-
Novel method of lung area extraction in chest perfusion computed tomography
PublikacjaChest perfusion computed tomography (pCT) is a useful technique in the medical diagnosis of how organs function. Perfusion CT scans are used to calculate perfusion parameters. In the case of automated methods of lung perfusion parameters calculation, the prior extraction of the lung area is desired to avoid unnecessary calculation in an area outside the lung cross-section and to avoid wasting time on processing signals of no diagnostic...
-
Usefulness of chest perfusion computed tomography in the diagnosis of diabetic pulmonary microangiopathy
PublikacjaThis paper presents the usefulness of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. We are looking for such measurements and perfusion parameters that provide the most accurate diagnosis. Two types of comparison were made based on the results of clinical trials:...
-
Role of quantitative chest perfusion computed tomography in detecting diabetic pulmonary microangiopathy
PublikacjaAims: Aimof the study was to determine the role of perfusion chest computed tomography(pCT) in evaluation of pulmonary diabetic angiopathy.Methods: 18 never-smoking patients (10 diabetic patients and 8 healthy controls) underwentchest high resolution CT (HRCT) and then pCT scanning. In both groups, blood tests,biochemical analysis, fibrinogen, HbA1c, spirometry, diffusion capacity for carbonmonoxide(DLCO) and body pletysmography...
-
Perfusion computed tomography: 4 cmversus8 cm coverage size in subjects with chronic carotid artery stenosis
PublikacjaOBJECTIVE: The impact of coverage size on global cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT) and time to peak (TTP) parameters has not been investigated in patients with chronic carotid artery stenosis. METHODS: 63 patients with stenosis of >70% within a single internal carotid artery and neurological symptoms were randomly assigned to two well-matched groups. Differences in CT perfusion scan...
-
Emphysema affects the number and appearance of solitary pulmonary nodules identified in chest low-dose computed tomography: a study on high risk lung cancer screenees recruited in Silesian District
Publikacja -
Computed tomography indicators of cerebral microperfusion improve long term after carotid stenting in symptomatic patients
PublikacjaOBJECTIVES: We tested the hypothesis that computed tomography (CT) perfusion markers of cerebral microcirculation would improve 36 months after internal carotid artery stenting for symptomatic carotid stenosis while results obtained 6-8 weeks after the stenting procedure would yield a predictive value. METHODS: We recruited consecutive eligible patients with >70% symptomatic carotid stenosis with a complete circle of Willis and...
-
Lung perfusion parameters in the diagnosis of diabetic pulmonary microangiopathy
PublikacjaThis paper presents the role of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. In this article we focus on conditions that are necessary for such the diagnosis and introduce method of classification no microangiopathy vs. microangiopathy based on logistic regression....
-
Proposal of New Tracer Concentration Model in Lung PCT Study Comparison with Commonly Used Gamma-variate Model
PublikacjaPerfusion computed tomography (pCT) is one of the methods that enable non-invasive imaging of the hemodynamics of organs and tissues. On the basis of pCT measurements, perfusion parameters such as blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) are calculated and then used for quantitative evaluation of the tissue condition. To calculate perfusion parameters it is necessary to approximate...
-
Rating mathematical models for first-pass of tracer in pCT lung studies
PublikacjaThis paper presents a comparison of model based on the Gauss function and the most commonly used Gamma-variate model in perfusion computed tomography (pCT) lung studies. It also verifies whether used model affects value of blood volume parameter. Three mean concentration-time curves were created from actual pCT measurements: arterial input function, blood vessels in lungs and lung parenchyma. On the basis of these mean curves we...
-
Carotid Artery Stenting and Blood–Brain Barrier Permeability in Subjects with Chronic Carotid Artery Stenosis
PublikacjaFailure of the blood-brain barrier (BBB) is a critical event in the development and progression of diseases such as acute ischemic stroke, chronic ischemia or small vessels disease that affect the central nervous system. It is not known whether BBB breakdown in subjects with chronic carotid artery stenosis can be restrained with postoperative recovery of cerebral perfusion. The aim of the study was to assess the short-term effect...
-
Information Extraction from Polish Radiology Reports using Language Models
PublikacjaRadiology reports are vital elements of directing patient care. They are usually delivered in free text form, which makes them prone to errors, such as omission in reporting radiological findings and using difficult-to-comprehend mental shortcuts. Although structured reporting is the recommended method, its adoption continues to be limited. Radiologists find structured reports too limiting and burdensome. In this paper, we propose...
-
Regional resting state perfusion variability and delayed cerebrovascular uniform reactivity in subjects with chronic carotid artery stenosis
PublikacjaThe aim of this study was to assess regional perfusion at baseline and regional cerebrovascular resistance (CVR) to delayed acetazolamide challenge in subjects with chronic carotid artery stenosis.Sixteen patients (ten males) aged 70.94±7.71 with carotid artery stenosis ≥90% on the ipsilateral side and ≤50% on the contralateral side were enrolled into the study. In all patients, two computed tomography perfusion examinations were...
-
Application of the X-ray micro computed tomography to the analysis of the structure of polymeric materials
PublikacjaIn this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important...
-
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
Adaptive Hounsfield Scale Windowing in Computed Tomography Liver Segmentation
PublikacjaIn computed tomography (CT) imaging, the Hounsfield Unit (HU) scale quantifies radiodensity, but its nonlinear nature across organs and lesions complicates machine learning analysis. This paper introduces an automated method for adaptive HU scale windowing in deep learning-based CT liver segmentation. We propose a new neural network layer that optimizes HU scale window parameters during training. Experiments on the Liver Tumor...
-
Journal of Cardiovascular Computed Tomography
Czasopisma -
Imaging of Increasing Damage in Steel Plates Using Lamb Waves and Ultrasound Computed Tomography
PublikacjaThis paper concerns inspection of steel plates, with particular emphasis on the assessment of in-creasing damage. Non-destructive tests were performed on four plates, one of which was un-damaged, while the remaining three had a defects in the form of circular holes with a diameter of 2, 5, and 10 cm. Guided Lamb waves were used in the research, and the image reconstruction was performed using ultrasound computed tomography. The...
-
Abdominal Aortic Aneurysm segmentation from contrast-enhanced computed tomography angiography using deep convolutional networks
PublikacjaOne of the most common imaging methods for diagnosing an abdominal aortic aneurysm, and an endoleak detection is computed tomography angiography. In this paper, we address the problem of aorta and thrombus semantic segmentation, what is a mandatory step to estimate aortic aneurysm diameter. Three end-to-end convolutional neural networks were trained and evaluated. Finally, we proposed an ensemble of deep neural networks with underlying...
-
Enhancing Renal Tumor Detection: Leveraging Artificial Neural Networks in Computed Tomography Analysis
PublikacjaRenal cell carcinoma is one of the most common cancers in Europe, with a total incidence rate of 18.4 cases per 100 000 population. There is currently significant overdiagnosis (11% to 30.9%) at times of planned surgery based on radiological studies. The purpose of this study was to create an artificial neural network (ANN) solution based on computed tomography (CT) images as an additional tool to improve the differentiation of...
-
Assessment of particular abdominal aorta section extraction from contrast-enhanced computed tomography angiography
PublikacjaThe aim of this work is to improve the accuracy of extraction of a particular abdominal aorta section and to reduce the distortion in three-dimensional Computed Tomography Angiography (CTA) images. Imaging modality and quality plays crucial role in the medical diagnostic process, thus ensuring high quality of images is essential at every stage of acquisition and processing.Noise is defined as a disturbance of the image quality...
-
Computed Tomography in Evaluation of Revision Hip Arthroplasty Outcomes
Publikacja -
Dual-Energy Computed Tomography in Loosening of Revision Hip Prosthesis
Publikacja -
Soft Tissue Retraction Maneuver in Cone Beam Computed Tomography Prior to Crown-Lengthening Procedure—A Technical Note
PublikacjaBackground: An accurate determination of the biological width and the relationship of the cemento-enamel junction with the border of the alveolar bone is crucial during a clinical crown-lengthening (CCL) procedure. The aim of this study was to present a technical note about the retraction techniques in cone beam computed tomography (CBCT) prior to CCL, highlighting the significant enhancement in procedural accuracy and predictability...
-
Mechanical and fracture properties of concrete reinforced with recycled and industrial steel fibers using Digital Image Correlation technique and X-ray micro computed tomography
PublikacjaPaper presents investigation of fracture phenomenon in plain concrete and in concrete reinforced with both recycled steel fibers (RSF) and industrial steel fibers (ISF). The wedge splitting test (WST), which enables stable crack propagation for quasi-brittle materials, was carried out on 75 75 75 mm cube samples. Initially, fracture process zone development was investigated only on the surface of samples using Digital Image Correlation...
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublikacjaThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Use of X-Ray Computed Tomography for Ice Detection Applied to Organ Cryopreservation
Publikacja -
Ovarian tissue cryopreservation by stepped vitrification and monitored by X-ray computed tomography
Publikacja -
A New Classification of the Morphology of Complete Ponticulus Posticus on Cone Beam Computed Tomography
Publikacja -
The effect of impacted third molars on second molar external root resorption, a cross-sectional cone beam computed tomography study
PublikacjaBackground: Third molars have the highest prevalence of impaction in teeth and can cause pathological damage on the adjacent second molars. This study aims to evaluate the effects of factors related to impacted third molars on external root resorption (ERR) in adjacent second molars using cone-beam computed tomography (CBCT). Material and Methods: In CBCTs, the effect of impacted third molars on the root surface of adjacent second...
-
Morphometric evaluation of the delayed cerebral arteries response to acetazolamide test in patients with chronic carotid artery stenosis using computed tomography angiography
PublikacjaBackground: The evidence accumulates that the response to acetazolamide test is delayed on the ipsilateral side to stenosis. However, the effect of acetazolamide beyond 30 minutes after acetazolamide administration remains unknown. The aim of this study was to assess the diameters of: anterior cerebral arteries (ACAs), middle cerebral arteries (MCAs) and posterior cerebral arteries (PCAs) before and 60 minutes after the acetazolamide...
-
Experimental investigations of fracture process in concrete by means of x-ray micro-computed tomography
PublikacjaW artykule pokazano doświadczalne wyniki badań procesu pękania w betonie stosując mikro-tomografię. Doświadczenia wykonano dla zginanych belek betonowych. Wyniki doświadczalne modelowano stosując MES na bazie modelu z degradacją sztywności sprężystej z nielokalnym osłabieniem. Beton symulowano jako materiał 4-fazowy. Uzyskano dobra zgodność wyników MES z doświadczeniami.
-
Mechanical and radiation shielding properties of concrete reinforced with boron--basalt fibers using Digital Image Correlation and X--ray micro--computed tomography
PublikacjaThe paper presents experimental investigations of the radiation shielding, mechanical and fracture properties of concrete reinforced with 5 kg/m3 of novel basalt fibers infused with boron oxide (BBF). However, further studies concerning other dosages i.e. 1 kg/m3, 10 kg/m3, 15 kg/m3 and 20 kg/m3 are currently carried out. Experiments with neutron source revealed that addition of BBF as a dispersed concrete reinforcement could improve...
-
Intracranial hemorrhage detection in 3D computed tomography images using a bi-directional long short-term memory network-based modified genetic algorithm
PublikacjaIntroduction: Intracranial hemorrhage detection in 3D Computed Tomography (CT) brain images has gained more attention in the research community. The major issue to deal with the 3D CT brain images is scarce and hard to obtain the labelled data with better recognition results. Methods: To overcome the aforementioned problem, a new model has been implemented in this research manuscript. After acquiring the images from the Radiological...
-
Assessment of the cryoprotectant concentration inside a bulky organ for cryopreservation using X-ray computed tomography
Publikacja -
Endodontic Treatment Outcomes in Cone Beam Computed Tomography Images—Assessment of the Diagnostic Accuracy of AI
Publikacja -
Solitary median maxillary central incisor syndrome: cone beam computed tomography illustrated review
Publikacja -
Visualizing the macroscale spatial distributions of biofilms in complex flow channels using industrial computed tomography
Publikacja -
The diagnostic accuracy of cone beam computed tomography in detecting temporomandibular joint bony disorders: a systematic review
Publikacja -
Shear fracture of longitudinally reinforced concrete beams under bending using Digital Image Correlation and FE simulations with concrete micro-structure based on X-ray micro-computed tomography images
PublikacjaThe paper presents experimental and numerical investigations of the shear fracture in rectangular concrete beams longitudinally reinforced with steel or basalt bar under quasi-static three point bending. Shear fracture process zone formation and development on the surface of beams was investigated by Digital Image Correlation (DIC) whereas thorough analyses of 3D material micro-structure, air voids, width and curvature of shear...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #3)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #1)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #4)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #2)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
An optimized controlled rate slow cooling protocol for bovine ovarian tissue cryopreservation by means of X-ray computed tomography
Publikacja -
Bimodal Nd-Doped LuVO4 Nanoprobes Functionalized with Polyacrilic Acid for X-Ray Computed Tomography and NIR Luminescent Imaging
Publikacja -
Mitigation effect of face shield to reduce SARS-CoV-2 airborne transmission risk: Preliminary simulations based on computed tomography
PublikacjaWe aimed to develop a model to quantitatively assess the potential effectiveness of face shield (visor) in reducing airborne transmission risk of the novel coronavirus SARS-CoV-2 during the current COVID-19 pandemic using the computational fluid dynamics (CFD) method. The studies with and without face shield in both an infected and healthy person have been considered in indoor environment simulation. In addition to the influence...
-
Effect of exercise training on insulin sensitivity, mitochondria and computed tomography muscle attenuation in overweight women with and without polycystic ovary syndrome
Publikacja -
Mitigation effect of face shield to reduce SARS-CoV-2 airborne transmission risk: Preliminary simulations based on computed tomography
PublikacjaWe aimed to develop a model to quantitatively assess the potential effectiveness of face shield (visor) in reducing airborne transmission risk of the novel coronavirus SARS-CoV-2 during the current COVID-19 pandemic using the computational fluid dynamics (CFD) method. The studies with and without face shield in both an infected and healthy person have been considered in indoor environment simulation. In addition to the influence...
-
The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study
Publikacja -
Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries
Publikacja