Filtry
wszystkich: 409
Wyniki wyszukiwania dla: impedance monitoring
-
Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements
PublikacjaWe proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...
-
Variable-Fidelity Simulation Models and Sparse Gradient Updates for Cost-Efficient Optimization of Compact Antenna Input Characteristics
PublikacjaDesign of antennas for the Internet of Things (IoT) applications requires taking into account several performance figures, both electrical (e.g., impedance matching) and field (gain, radiation pattern), but also physical constraints, primarily concerning size limitation. Fulfillment of stringent specifications necessitates the development of topologically complex structures described by a large number of geometry parameters that...
-
Chemical-Assisted Mechanical Lapping of Thin Boron-Doped Diamond Films: A Fast Route Toward High Electrochemical Performance for Sensing Devices
PublikacjaThere is an urgent need for an effective and economically viable increase in electrochemical performance of boron-doped diamond (BDD) electrodes that are used in sensing and electrocatalytic applications. Specifically, one must take into consideration the electrode heterogeneity due to nonhomogenous boron-dopant distribution and the removal of sp2 carbon impurities saturating the electrode, without interference in material integrity....
-
Application of Wavelet Transform and Fractal Analysis for Esophageal pH-Metry to Determine a New Method to Diagnose Gastroesophageal Reflux Disease
PublikacjaIn this paper, a new method for analysing gastroesophageal reflux disease (GERD) is shown. This novel method uses wavelet transform (WT) and wavelet-based fractal analysis (WBFA) on esophageal pH-metry measurements. The esophageal pH-metry is an important diagnostic tool supporting the physician’s work in diagnosing some forms of reflux diseases. Interpreting the results of 24-h pH-metry monitoring is time-consuming, and the conclusions...
-
Impedance of cation-coupled electron transfer reaction: Theoretical description of one pathway process
PublikacjaIt has been assumed that cation electron coupled charge transfer can be conducted in accordance with two mutually coupled reactions. Using a differential method an expression was introduced which describes the impedance of a cation electron coupled transfer reaction. Also, an electrical equivalent circuit has been defined. The total faradaic impedance is the sum of electron transfer impedance and cation transfer impedance. Issues...
-
Polynomial analysis as a new way of describing dynamic impedance spectra – Differential and relative impedance spectra
PublikacjaModel measurements of an equivalent electrical system were carried out using the technique of Dynamic Electrochemical Impedance Spectroscopy. The measurement took the form of potentiodynamic changes imposed on the tested system. Using the possibility of continuous impedance measurements, an attempt was made to develop an original and innovative method of analyzing impedance spectrograms, which is termed polynomial analysis. As...
-
Fast High-Impedance Spectroscopy Method Using SINC Signal Excitation
PublikacjaIn this paper the method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 Gohm) is evaluated by means of simulation and practical experiment. The method is based on excitation of an object with a sinc signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance spectrum is obtained with use of continuous Fourier transform...
-
Programmable dynamically changing RC model for evaluation of Dynamic EIS methods and instrumentation
PublikacjaThe paper concerns the RC equivalent circuit of electrochemical cell with the impedance changed during the experiment. The model was constructed using the digital potentiometers controlled by the microcontroller. This solution allows to control the model impedance by the software means. By creating adequate changes of the impedance spectrum as a time function, the different impedance measurement method can be tested to find out...
-
Using A Particular Sampling Method for Impedance Measurement
PublikacjaThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
A complete impedance analysis of electrochemical cells used as energy sources
PublikacjaA comprehensive description of impedance ofelectrochemical systems has been presented, along withthe assumptions of the method used. In this method, amultisinusoidal current excitation signal is used. Thechanges of potential of both the electrodes and thepotential difference between these electrodes are allregistered simultaneously as a function of time. Theproposed method offers the possibility of separatelydetermining the instantaneous...
-
Application of dynamic impedance spectroscopy to scanning probe microscopy.
PublikacjaDynamic impedance spectroscopy, designed for measuring nonstationary systems, was used in combination with scanning probe microscopy. Using this approach, impedance mapping could be carried-out simultaneously with topography scanning. Therefore, correlation of electrical properties with particular phases of an examined sample was possible. The sample used in this study was spheroidal graphite cast iron with clearly defined phases...
-
Study of Direct Methanol Fuel Cell Process Dynamics Using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaA new technique, which was developed to characterize the direct methanol fuel cell under work conditions, has been presented in this paper. The impedance measurements were made using dynamic electrochemical impedance spectroscopy research technique in the galvanostatic mode, using multiple sinusoidal excitation. Obtained results show, that together with an increase of the temperature and working load, the global impedance...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublikacjaThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Selection of excitation signals for high-impedance spectroscopy
PublikacjaA method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 GOhm) is evaluated in this paper. An object is excited with a signal generated by a digital-to-analog converter (DAC) located on the U2531A DAQ module. Response signals proportional to current flowing through and voltage across the measured object are sampled by analog-to-digital converters (ADC) in the DAQ module. The object impedance spectrum...
-
An integral-differential method for impedance determination of the hydrogen oxidation process in the presence of carbon monoxide in the proton exchange membrane fuel cell
PublikacjaThe impedance of a proton exchange membrane fuel cell powered by hydrogen contaminated with carbon monoxide, ranging from 150 to 300 ppb, is measured and discussed. The tested range of CO concentration complied with the fuel standard specified in the ISO standards. Studies of influence of CO contamination on operation of PEMFC are crucial for further development and commercialization of fuel cells for automotive applications. Based...
-
Platform Supporting the Esophageal Impedance Analysis
PublikacjaThe esophageal pH-impedance examination is one of the most popular diagnostic methods for identifying the upper gastrointestinal tract’s diseases. Inconclusive test evaluation criteria makes it difficult to state the definite diagnosis. In this paper, the computer platform supporting the research and teaching process in the area of pH-impedance analysis is presented. Users, having a variety of mathematical and statistical methods...
-
Evaluation of Temperature Influence on Electrochemical Processes Occurring in a Lithium-Ion Supercapacitor with the Use of Dynamic Electrochemical Impedance Spectroscopy
PublikacjaIn order to obtain the full impedance characteristics of a lithium-ion capacitor as a function of temperature, the authors proposed the use of dynamic electrochemical impedance spectroscopy. Impedance tests were carried out under wide range of dynamic temperature changes for lithium-ion supercapacitors. Significant differences in electrochemical processes were observed as a result of working temperature. Moreover, the quality of...
-
Local properties of organic coatings close to glass transition temperature
PublikacjaAcrylic coating applied on copper substrate has been investigated at different temperatures starting from the ambient one up to the level above the glass transition temperature. Its local topographic and electric properties have been examined with the atomic force microscopy (AFM) based approach including dc current mapping and local impedance spectroscopy. The local findings have been compared with the information from global...
-
Electrical and mechanical characterization of two-phase alloys by means of scanning probe microscopy in dynamic impedance spectroscopy mode
PublikacjaDynamic impedance spectroscopy, evaluated for measuring non-stationary systems, was used in combination with scanning probe microscope. Using this approach, localized impedance measurements in the AFM contact mode could be carried out. Additionally, impedance–force curves were made at each phase of investigated materials to illustrate the relation between impedance and the force applied to a probe. Therefore, correlation of electrical...
-
Assessment of organic coating degradation via local impedance imaging
PublikacjaThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...