Wyniki wyszukiwania dla: nir
-
Human subarachnoid space width oscillations in the resting state
PublikacjaAbnormal cerebrospinal fluid (CSF) pulsatility has been implicated in patients suffering from various diseases, including multiple sclerosis and hypertension. CSF pulsatility results in subarachnoid space (SAS) width changes, which can be measured with near-infrared transillumination backscattering sounding (NIR-T/BSS). The aim of this study was to combine NIR-T/BSS and wavelet analysis methods to characterise the dynamics of the...
-
The luminescence study of Ga2–x(Al0.68In0.32)xO3:Cr3+ coumpounds.
Dane BadawczeNear-infrared (NIR) phosphor-converted light-emitting diodes (pc-LEDs) are a highly efficient perspective NIR light source, with application hindered by a narrow emission band. In this work, we broaden the emission of a new series of NIR phosphors by controlling crystal structure disorder through cation cosubstitution. By substituting Ga3+ with (Al0.68In0.32)3+,...
-
The luminescence study of Ca14Zn6Ga10−xMnxO35 coumpounds.
Dane BadawczeManganese in the pentavalent state (Mn 5+) is both rare and central in materials exhibiting narrow-band near-infrared (NIR) emission and is highly sought after for phosphor-converted light-emitting diodes as promising candidates for future miniature solid-state NIR light source. We develop the Ca 14 Zn 6 Ga 10−x Mn x O 35 (x = 0.3, 0.5, 1.0, 1.25, 1.5,...
-
Application of vibrational spectroscopy, thermal analyses and X-Ray diffraction in the rapid evaluation of the stability in solid-state of ranitidine, famotidine and cimetidine
PublikacjaThis paper reports the study on applicability of Fourier transform infrared (FTIR), near-infrared (NIR) and Raman spectroscopy, differential scanning calorimetry (DSC) and X-ray diffraction (XRD) for the estimation of the chemical stability and photostability of histamine H2-receptor antagonist substances. Ranitidine hydrochloride (RAN), famotidine (FAM) and cimetidine (CIM) were tested and differences in sensitivity were measured...
-
Determination of API content in a pilot-scale blending by near-infrared spectroscopy as a first step method to process line implementation
PublikacjaNear infrared (NIR) spectroscopy was used for estimation of powder blend homogeneity and manufacturing control of a medicinal product powder mixture containing active pharmaceutical ingredient (API). Aiming at initiating a Process Analytical Technology (PAT) activity, the first step was a stationary mode atline evaluation. In this, the content of pharmaceutical active compound in the powder mixtures intended to the direct tabletting...
-
The luminescence study of CsPbI3 nanoparticles embedded in Cs4PbI6 crystals.
Dane BadawczeCs4PbI6, as a rarely investigated member of the Cs4PbX6 (X is a halogen element) family, has been successfully synthesized atlow temperatures by collaborators from National Taiwan University. Strong red to near-infrared (NIR) emission properties have been detected, and its optical emission centers have been identified to be numerous embedded perovskite-type...
-
WPŁYW TRANSFORMACJI DANYCH NA JAKOŚĆ OPRACOWANYCH METOD TOŻSAMOŚCIOWYCH W SPEKTROSKOPII BLISKIEJ PODCZERWIENI
PublikacjaSpektroskopia bliskiej podczerwieni (NIR) wykorzystuje absorpcję promieniowania elektromagnetycznego w zakresie 12000-4000 cm-1, (780¬-2500 nm). Absorpcja NIR pochodzi od nadtonów i drgań kombinacyjnych wiązań C-H, N-H, O-H. Widmo uzyskane techniką NIR jest unikatowym "odciskiem palca" badanej substancji gdyż zależy zarówno od właściwości fizyko-chemicznych próbki jak i od stanu fazowego oraz postaci krystalicznej jej składników.Zaletami...
-
Effects of laser pulse duration in two-photon vision threshold measurements
PublikacjaPulsed near-infrared (NIR) light sources can be successfully applied for both imaging and functional testing of the human eye, as published recently1. These two groups of applications have different requirements. For imaging applications, the most preferable is invisible scanning beam while efficiently visible stimulating beam is preferable for functional testing applications. The functional testing of human eye using NIR laser...
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublikacjaAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
Effect of Maximal Breath Hold Apnea on Pial Artery Pulsation and Subarachnoid Width in Human
PublikacjaLittle is known about intracranial pressure (ICP)-cerebral hemodynamic interplay during maximal breath-hold apnea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Changes in sas-TQ correlate with ICP to a considerable extent, whereas cc-TQ reflects the functional...
-
Optical properties of the chemotherapy drugs used in the central nervous system lymphoma therapy: monitoring drug delivery
PublikacjaOur aim is to optically monitor the delivery of the chemotherapy drugs for brain tumours, particularly used in the central nervous system (CNS) lymphoma therapy. In vivo monitoring would help to optimize the treatment and avoiding unnecessary medications. Moreover, it would be beneficial to be able to measure which of the multi-regimen drugs actually do penetrate and how well into the brain tissue. There exist several potential...
-
Electrochemically Induced Synthesis of Triphenylamine-based Polyhydrazones
PublikacjaTriphenylamine-based hydrazones were subjected to electropolymerization process that gave well conductive hydrazone based polymers. The first example of polyhydrazone formation during the electrochemical process was shown. The estimation of polymer structure was demonstrated using IR spectroelectrochemistry. The EPR spectroelectrochemistry allowed to explain why in some cases dimer couldn’t be formed. The results of electrochemical,...
-
Pial artery and subarachnoid width response to apnoea in normal humans
PublikacjaBackground: Little is known about intracranial pressure (ICP)-cerebral haemodynamic interplay during repetitive apnoea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Method: We tested the complex response of the pial artery and subarachnoid width to apnoea...
-
Studies on the influence of β-cyclodextrin derivatives on the physical stability of famotidine
PublikacjaThe usage of Fourier transform infrared spectroscopy, near infrared spectroscopy, differential scanning calorimetry and microscopy is presented in this work focused on the exploration of the effect of CD on the physical stability of famotidine (FAM). The most significant information was achieved by analysis of the second derivatives ofnear infrared (NIR) spectra recorded. Changes in the shape of spectra derivatives allow...
-
Sposoby i skutki fałszowania paliw silnikowych oraz metody wykrywania.Cz. 2
PublikacjaPrzedstawiono dwie grupy metod kontroli jakości paliwa - metody konwencjonalne i wybrane ''metody przesiewowe'' - w tym zastosowanie spektrofotometrii w bliskiej podczerwieni (NIR), które umożliwiają identyfikację sfałszowanego paliwa. Opisano także metodykę badań prowadzącą do oznaczenia nieznanego parametru użytkowego badanego paliwa, począwszy od utworzenia optymalnych postaci równań korelacyjnych poprzez kontrolę ich poprawności...
-
Evidence for solid state electrochemical degradation within a small molecule OLED
PublikacjaAcridone derivative have been synthesised and used as OLED (Organic Light Emitting Diode) emitters which were found to be electroactive. Electrochemical investigations showed a side reaction takes place inside an active layer which diminished the overall device efficiency. By using a dopant and host active layer architecture, the formation of the by product was removed. The by-product was identified as a σ-dimer formed inside an...
-
Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
PublikacjaPial artery adjustments to changes in blood pressure (BP)may last only seconds in humans. Using a novelmethod called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of...
-
Effect of Maximal Apnoea Easy-Going and Struggle Phases on Subarachnoid Width and Pial Artery Pulsation in Elite Breath-Hold Divers
PublikacjaPurpose: The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on...
-
Polydopamine Biomaterials for Skin Regeneration
PublikacjaDesigning biomaterials capable of biomimicking wound healing and skin regeneration has been receiving increasing attention recently. Some biopolymers behave similarly to the extracellular matrix (ECM), supporting biointerfacial adhesion and intrinsic cellular interactions. Polydopamine (PDA) is a natural bioadhesive and bioactive polymer that endows high chemical versatility, making it an exciting candidate for a wide range of...
-
Optoelectronic device for hematocrit measurements
PublikacjaAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...