Filtry
wszystkich: 5229
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: FIXED CONNECTION
-
NUMERICAL MODELLING AND EXPERIMENTATION OF HISTORICAL CARPENTRY CORNER LOG JOINTS
PublikacjaThe main purpose of this research is to determine the stress distributions on the contact surfaces between the logs of the historical carpentry corner joints. The additional purpose is to compare the stress distribution for four different boundary conditions in the case of dry and wet pine wood. The paper presents the results of numerical analysis of the shortcorner dovetail connection and the saddle notch corner joint, which are...
-
Sustainable Use of the Catenary by Trolleybuses with Auxiliary Power Sources on the Example of Gdynia
PublikacjaThe current developments in onboard power source technology, in particular, traction batteries, open up new potential in trolleybus transport and also make it possible to introduce electric buses. Thus far, trolleybus transport has required the presence of overhead lines (OHL). Introducing trolleybuses with onboard batteries makes it possible to grow the zero-emissions transport network in places with limited power supply capabilities...
-
International Conference on Creating Connecting and Collaborating through Computing
Konferencje -
IEEE/ACM International Symposium on Mixed and Augmented Reality
Konferencje -
Conception and design of a hybrid exciter for brushless synchronous generator. Application for autonomous electrical power systems = Koncepcja i projekt hybrydowej wzbudnicy bezszczotkowego generatora synchronicznego. Zastosowanie w autonomicznych systemach elektroenergetycznych.
PublikacjaThis paper covers a subject of a hybrid excitation system for a brushless synchronous generator working with variable speed in an autonomous energy generation system (e.g. airplane power grid). A hybrid excitation system (hybrid exciter) means a synchronous machine with wound-field and permanent magnet excitation. The hybrid exciter supply a dc field current to the synchronous generator field winding through a rotating rectifier....
-
Conception and design of a hybrid exciter for brushless synchronous generator. Application for autonomous electrical power systems = Koncepcja i projekt hybrydowej wzbudnicy bezszczotkowego generatora synchronicznego. Zastosowanie w autonomicznych systemach elektroenergetycznych
PublikacjaIn this paper a hybrid excitation system for a brushless synchronous generator working with variable speed in an autonomous energy generation system (e.g. airplane power grid) has been presented. A conception of a dual-stator hybrid exciter has been proposed. Comparison study of classical and hybrid exciter has been carried out. For the electromagnetic calculation two approaches have been applied: an analytical approach (based...
-
Author Correction: Risk factors for serious morbidity, prolonged length of stay and hospital readmission after laparoscopic appendectomy - results from Pol-LA (Polish Laparoscopic Appendectomy) multicenter large cohort study
Publikacja -
Load capacity of steel-aluminium brackets under static and cyclic laboratory tests
PublikacjaThe aim of the research is the laboratory investigation of steel-aluminium brackets employed to fasten lightweight curtain walls to building facilities. Static pressure, suction forces, and cyclic loads parallel to end plates (horizontal – to simulate wind influence) were applied in the study. The steel-aluminium brackets were tested on a reinforced concrete substrate made of C30/37 concrete class to simulate the real working conditions....
-
Contemporary bottom-up tools for public spaces activation. Współczesne oddolne narzędzia aktywizacji przestrzeni publicznych
PublikacjaThis article attempts to figure out the current understanding of public spaces and the contemporary tools for bottom-up activation of public spaces to make them more friendly and functional. The paper investigates contemporary public spaces' challenges and what tools can be used to improve them. In this research, the main issue will be the question: what kind of tools and actions can be offered to maintain the quality of public...
-
Problemy przyłączania farm wiatrowych do systemu elektroenergetycznego z wykorzystaniem kabli WN
PublikacjaArtykuł prezentuje problemy, jakie rodzi przyłączanie farm wiatrowych do systemu elektroenergetycznego za pomocą kabli wysokiego napięcia. Autor wskazuje możliwe problemy z kompensacją mocy biernej, w zależności od sposobu przyłączenia dławika kompensacyjnego i nastawień układów regulacji mocy biernej oraz napięcia farmy wiatrowej. Artykuł porusza też zagadnienia zwiększenia strat mocy czynnej powodowanych instalacją dławików kompensacyjnych.
-
Correction: Profiles of a broad spectrum of epigenetic DNA modifications in normal and malignant human cell lines: Proliferation rate is not the major factor responsible for the 5-hydroxymethyl-2′-deoxycytidine level in cultured cancerous cell lines
Publikacja -
Hebb–Wagner polarization method for determining the oxygen ion conductivity in barium cerate-zirconate
PublikacjaIn this work, the partial conductivity of oxygen ions in BaCe0.6Zr0.2Y0.2O3 was studied at different temperatures and water partial pressures. For this purpose, a modified DC Hebb–Wagner polarization method with an electrode blocking for protons and electrons was used. A new type of measuring cell as well as a suitable calculation model were proposed for the determination of partial oxygen ionic conductivity in materials with three...
-
Relations between magnetosonic perturbations as an indicator of a magnetosonic exciter and equilibrium parameters of a plasma
PublikacjaThe thermodynamic relations between perturbation of pressure and pertur- bation of mass density and between components of velocity which specify a magnetosonic wave are theoretically studied. A planar flow with the wave vec- tor forming a constant angle with the equilibrium magnetic field is investigated. The theory considers deviation from the adiabaticity of a flow due to some kind of heating–cooling function and thermal conduction...
-
Modelling of elastic wave propagation in a bolted joint using a thin layer of shell elements
PublikacjaThere are many mathematical models describing the propagation of elastic waves through the imperfect boundary of two media. They were successfully applied to modelling of high frequency bulk waves and their interaction with local defects. On the other hand, the existing literature models of bolted connections ignore the aspect of imperfect connection between elements. Therefore, this paper presents the concept of application of...
-
Metoda analizy wielokryterialnej do planowania rozwoju sieci elektroenergetycznej średniego i niskiego napięcia
PublikacjaW artykule przedstawiono metodę wspomagającą decyzje w zakresie wyboru wariantu przyłączenia odbioru do sieci elektroenergetycznej dystrybucyjnej niskiego napięcia lub średniego napięcia oraz mikrogeneracji do sieci niskiego napięcia. Metodę tą zaimplementowano w skoroszycie kalkulacyjnym Microsoft Excel i zastosowano do analizy złożonych przypadków przyłączenia odbioru lub mikrogeneracji.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010191511]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010196151]
Dane BadawczeThis is the histopathological image of BLADDER tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [30706300101931]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010194311]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010187061]
Dane BadawczeThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010197481]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010193841]
Dane BadawczeThis is the histopathological image of ADRENAL GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [307063001019261]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [307063001019161]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010192001]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3300730069446041]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010186761]
Dane BadawczeThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010185641]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010198521]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010185951]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010199221]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010195311]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010183651]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010192081]
Dane BadawczeThis is the histopathological image of SMALL INTESTINE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010198001]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010199421]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010197331]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010192831]
Dane BadawczeThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010198731]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010195811]
Dane BadawczeThis is the histopathological image of STOMACH tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010196251]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010191831]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010193741]
Dane BadawczeThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010195701]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010199881]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [307063001018791]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [3070630010199371]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 0 - Tissue image [7060729599339411]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Discordant ventriculoarterial connection - Male, 1 - Tissue image [307063001019471]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Variable Fractional Delay Filter Design Using a Symmetric Window
PublikacjaIn this paper a numerically efficient method for designing a nearly optimal variable fractional delay (VFD) filter based on a simple and well-known window method is presented. In the proposed method a single window extracted from the optimal filter with fixed fractional delay (FD) is divided into even and odd part. Subsequently, the odd part is discarded and symmetric even part of the extracted window is used to design a family...