Filtry
wszystkich: 1725
-
Katalog
- Publikacje 1333 wyników po odfiltrowaniu
- Czasopisma 3 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Osoby 7 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Kursy Online 2 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 377 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: NDFEB ALLOY
-
Inlet air fogging of marine gas turbine in power output loss compensation
PublikacjaThe use of inlet air fogging installation to boost the power for gas turbine engines is widely applied in the power generation sector. The application of fogging to mechanical drive is rarely considered in the literature [1]. This paper will cover some considerations relating to its application to gas turbines in ship drive. There is an important evaporative cooling potential throughout the world when the dynamic data is evaluated,...
-
Texture Features for the Detection of Playback Attacks: Towards a Robust Solution
PublikacjaThis paper describes the new version of a method that is capable of protecting automatic speaker verification (ASV) systems from playback attacks. The presented approach uses computer vision techniques, such as the texture feature extraction based on Local Ternary Patterns (LTP), to identify spoofed recordings. Our goal is to make the algorithm independent from the contents of the training set as much as possible; we look for the...
-
Efficient three-dimensional fluorescence measurements for characterization of binding properties in some plants
PublikacjaThe main aim of this research was to characterize some plants and to determine their similarities and differences, using spectroscopic methods. The interactions of soluble polyphenols of different plants with human serum albumin (HSA) were investigated by 3D-fluorescence. The obtained fluorescence results allow to classify the investigated plants according to their binding properties. The HSA-binding capacities of these plants...
-
Interplay of hydrogen bonding and aryl-perfluoroaryl interactions in construction of supramolecular aggregates
PublikacjaThe stacking between aryl and perfluoroaryl units is an important class of the aromatic – aromatic interactions that has attracted rapidly growing interest in recent years. Continuing interest of our group in this subject it had been prepared three new complexes of pentafluorobenzoic acid with benzyl alcohol, 4-methylbenzyl alcohol and 4-tert-butylbenzyl alcohol and in the next step investigated their self-assembly modes by...
-
On the impact of Big Data and Cloud Computing on a scalable multimedia archiving system
PublikacjaMultimedia Archiver (MA) is a system build upon the promise and fascination of the possibilities emerging from cloud computing and big data. We aim to present and describe how the Multimedia Archiving system works for us to record, put in context and allow a swift access to large amounts of data. We introduce the architecture, identified goals and needs taken into account while designing a system processing data with Big Data...
-
Wpływ stopowania laserowego z użyciem nanorurek węglowych stopu Ti13Nb13Zr do zastosowań biomedycznych na jego wybrane własności mechaniczne
PublikacjaDo eksperymentu użyto stopu tytanu Ti13Nb13Zr, który ze względu na swój skład chemiczny i właściwości mechaniczne stanowi materiał do zastosowań w inżynierii medycznej. Celem pracy była ocena wpływu stopowania laserowego stopu Ti13Nb13Zr z powłoką z wielościennych nanorurek węglowych na jego właściwości mechaniczne (chropowatość, nanotwardość, moduł Younga). Do wytworzenia powłoki węglowej wykorzystano metodę osadzania elektroforetycznego (EDP)....
-
Time series of Doppler blood flow recordings
Dane BadawczeVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.7, b=0.32) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.1, b=0.14) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=7.3, b=0.49) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.8, b=0.25) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.5, b=0.37) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=6.4, b=0.45) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=6.2, b=0.38) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.4, b=0.26) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=3.3, b=0.40) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.0, b=0.11) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=2.00, b=0.11) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=2.80, b=0.25) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=2.00, b=0.11) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=6.40, b=0.45) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=6.40, b=0.45) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=3.30, b=0.40) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...