Filtry
wszystkich: 1655
-
Katalog
- Publikacje 1287 wyników po odfiltrowaniu
- Czasopisma 13 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 95 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Laboratoria 2 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 48 wyników po odfiltrowaniu
- Wydarzenia 10 wyników po odfiltrowaniu
- Dane Badawcze 194 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: blue beam
-
Ultrasonic diagnostics of concrete T-beams used in bridge structures
PublikacjaThis paper describes a method of ultrasonic diagnostics used for prefabricated concrete elements. The studies are focused on the applicability of nondestructive techniques based on impulse and wave packet induced elastic waves for the condition assessment of T-shaped bridge beams. Experimental tests were performed for the prestressed beam used for the superstructure of the viaduct on A1 highway near Toruń. In addition numerical...
-
Temper bead welding of S420G2+M steel in water environment
PublikacjaThe article presents the idea of the use of Temper Bead Welding (TBW) technique to improve the weldability of high strength steel at underwater wet welding conditions. Wet welding method with the use of covered electrodes is described. This work shows results of metallographic examinations and hardness measurements of samples of S420G2+M steel with weld beads performed under water. It has been shown that Temper Bead Welding technique...
-
The Structure of Entrepreneurial Team Members’ Competencies: Between Effectuation and Causation
PublikacjaA conscious shaping of entrepreneurial competence is a relevant element of entrepreneurial education. In order to recognize which of the competencies regarded as entrepreneurial are characteristic of members of entrepreneurial teams, which is crucial for the work of those teams, it is necessary to identify the structure of those competencies. This quantitative study was conducted with the use of a survey method and involved 111...
-
Experimental Study of Dapped-End Beams Subjected to Inclined Load
PublikacjaThis paper presents the results of an experimental investigation of the reinforced concrete (RC) dapped-end beams loaded with inclined forces, compared to identical ones loaded with vertical forces only. Such a load may occur in, for example, Gerber's joints or in dapped-end beams supported on corbels, where the vertical gravitation force is additionally completed with horizontal forces caused by temperature differences, shrinking,...
-
Static and sensitivity analysis of thin-walled beams and frames with stiffeners.
PublikacjaPraca zawiera tekst referatu wygłoszonego w Maastricht. Przedstawiono analizę statyczną oraz analizę wrażliwości belek i ram zbudowanych z cienkościennych elementów, poddanych skręcaniu lub zginaniu ze skręcaniem, z możliwością zastosowania różnego typu stężeń . Wykorzystano technikę superelementu do wyznaczenia macierzy sztywności węzła ramy i elementów ze stężeniami. Otrzymane wyniki dla modelu jednowymiarowego MES porównano...
-
Blue nevus, NOS - Female, 42 - Tissue image [6290730011492981]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 37 - Tissue image [7110729594546561]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 25 - Tissue image [7110729594541591]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 64 - Tissue image [7110729594545121]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Male, 24 - Tissue image [6300730028269481]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, epithelioid - Unknown, 35 - Tissue image [3300730069395571]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Male, 33 - Tissue image [7040247104938751]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, epithelioid - Unknown, 35 - Tissue image [3300730069396841]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 35 - Tissue image [6060730023677431]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 46 - Tissue image [10100730045414471]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Male, 66 - Tissue image [6300730028266321]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 45 - Tissue image [6300730028266091]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 70 - Tissue image [7110729594544401]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 59 - Tissue image [7110729594545531]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 39 - Tissue image [7110729594544331]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 25 - Tissue image [617073002674731]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cellular blue nevus - Male, 38 - Tissue image [7110729594546711]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 36 - Tissue image [8190729597423171]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 37 - Tissue image [7110729594548251]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 63 - Tissue image [6130730026862571]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 51 - Tissue image [626073002189591]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Male, 42 - Tissue image [6130730026867861]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Male, 55 - Tissue image [6300730028261891]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
A modified hat problem
PublikacjaThe topic of our paper is the hat problem in which each of n players is randomly fitted with a blue or red hat. Then everybody can try to guess simultaneously his own hat color by looking at the hat colors of the other players. The team wins if at least one player guesses his hat color correctly, and no one guesses his hat color wrong; otherwise the team loses. The aim is to maximize the probability of a win. There are known many...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublikacjaIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
Research of Accuracy of RSSI Fingerprint-Based Indoor Positioning BLE System
PublikacjaRadio localization in indoor environment is still a challenging task due to environment volatility. In the paper are compared achieved localization accuracies for RSSI-Fingerprinting method utilizing Bluetooth Low Energy (BLE) for two different environments: large empty hall and narrow corridor. Measurements were done by 6 different smartphones of 3 different producers, which makes those measurements unique as accuracies achieved...
-
Research of Accuracy of RSSI Fingerprint-Based Indoor Positioning BLE System
PublikacjaRadio localization in indoor environment is still a challenging task due to environment volatility. In the paper are compared achieved localization accuracies for RSSI-Fingerprinting method utilizing Bluetooth Low Energy (BLE) for two different environments: large empty hall and narrow corridor. Measurements were done by 6 different smartphones of 3 different producers, which makes those measurements unique as accuracies achieved...
-
Fuzzy reasoning approach to properties' determination of calcium phosphate coatings processed using ion beam assisted deposition on heated substrates
PublikacjaPraca przedstawia rozmyty system wnioskowania dla zamodelowania związków pomiędzy temperaturą podłoża oraz stosunkiem molowym Ca/P w gradientowej powłoce hydroxyapatytowej na podłożu tytanowym. Przeprowadzono symulację działania sterownika rozmytego na pomocą oprogramowania Matlab.
-
CALIBRATION OF LOW ENERGY X-RAY EXPERIMENTAL SETUP WITH STRONGLY FILTERED BEAM USING DATA FROM A SEMICONDUCTOR AND A THERMOLUMINESCENT DETECTORS
Publikacja -
Scanning with Laser Beam over the TiO2 Nanotubes Covered with Thin Chromium Layers towards the Activation of the Material under the Visible Light
Publikacja -
Third harmonic generation studies of 1.06 μm Nd:YAG laser beam in Li2SO4–MgO–P2O5 glass system-influence of CuO
Publikacja -
The spectral finite element model for analysis of flexural-shear coupled wave propagation. Part 2: Delaminated multilayer composite beam
Publikacja -
SU‐E‐T‐103: Three‐Dimensional Measurements of Dose and LET from a Proton Beam via Polymer Gel Dosimetry
Publikacja -
The spectral finite element model for analysis of flexural-shear coupled wave propagation. Part 2, Delaminated multilayer composite beam
PublikacjaW pracy przedstawiono, wykorzystując metodę elementów spektralnych, analizę wpływu delaminacji na propagację fali giętno-ścinającej w belce kompozytowej.
-
The spectral finite element model for analysis of flexural-shear coupled wave propagation. Part 1, Laminated multilayer composite beam
PublikacjaW pracy przedstawiono model spectralnego elementu skończonego umożliwiającego symulację propagacji fali giętno-ścinającej w materiałąch kompozytowych.
-
The effect of impacted third molars on second molar external root resorption, a cross-sectional cone beam computed tomography study
PublikacjaBackground: Third molars have the highest prevalence of impaction in teeth and can cause pathological damage on the adjacent second molars. This study aims to evaluate the effects of factors related to impacted third molars on external root resorption (ERR) in adjacent second molars using cone-beam computed tomography (CBCT). Material and Methods: In CBCTs, the effect of impacted third molars on the root surface of adjacent second...
-
OPTICAL STRAIN MEASUREMENT OF CONCRETE VERSUS MANUAL EXTENSOMETER MEASUREMENT BASED ON THE TEST RC DEEP BEAM IN A COMPLEX STATE OF STRESS
PublikacjaThe purpose of this study is to compare the strain measurement techniques of concrete in R-C element subjected to the monotonic load up to the failure. In the analysis manual extensometer methods of measurements and the optical system ARAMIS for non-contact three-dimensional measurements of deformation was used. The test sample was a cantilever deep beam loaded throughout the depth which was a part of the reinforced concrete deep...
-
Stability analysis of nanobeams in hygrothermal environment based on a nonlocal strain gradient Timoshenko beam model under nonlinear thermal field
PublikacjaThis article is dedicated to analyzing the buckling behavior of nanobeam subjected to hygrothermal environments based on the principle of the Timoshenko beam theory. The hygroscopic environment has been considered as a linear stress field model, while the thermal environment is assumed to be a nonlinear stress field based on the Murnaghan model. The size-dependent effect of the nanobeam is captured by the nonlocal strain gradient...
-
Durability evaluation of Ni‐Cr‐Mo super alloys in a simulated scrubbed flue gas environment
Publikacja -
Prevention of heart failure mortality and hospitalizations in SPRINT, EMPA-REG, ALLHAT and HYVET: are diuretics the clue?
Publikacja -
Split-beam echosounder data from Gdansk Deep Summer 2019
Dane BadawczeThe acoustic data was collected in 2019, in the Gdansk Deep, in the season: Summer. Data was collected during the day and night. Three split-beam echosounders with frequencies of 38 kHz, 120 kHz and 333 kHz were used to collect the data. The data was collected while the ship was sailing. To ensure data quality, echosounders were calibrated and passive...
-
Mode shapes of a beam and plate with defects, obtained by experimental modal analysis
Dane BadawczeThe DataSet contains the experimental results of the first mode shape for a beam and a plate.
-
Split-beam echosounder data from Puck Bay autumn 2018
Dane BadawczeThe acoustic data was collected in 2018, in the Bay of Puck, in the seasons: autumn. Data was collected during the day and night. Three split-beam echosounders with frequencies of 38 kHz, 120 kHz and 333 kHz were used to collect the data. The data was collected at a designated study area not far from the city of Hel, while the ship was sailing. To ensure...
-
Split-beam echosounder data from Puck Bay spring 2019
Dane BadawczeThe acoustic data was collected in 2019, in the Bay of Puck, in the season: spring. Data was collected during the day and night. Three split-beam echosounders with frequencies of 38 kHz, 120 kHz and 333 kHz were used to collect the data. The data was collected at a designated study area not far from the city of Hel, while the ship was sailing. To ensure...
-
Split-beam echosounder data from Puck Bay winter 2019
Dane BadawczeThe acoustic data was collected in 2019, in the Bay of Puck, in the season: winter. Data was collected during the day and night. Three split-beam echosounders with frequencies of 38 kHz, 120 kHz and 333 kHz were used to collect the data. The data was collected at a designated study area not far from the city of Hel, on the route Hel - Gdynia and on...