dr inż. Andrzej Kwiatkowski
Employment
- Assistant professor at Department of Metrology and Optoelectronics
Publications
Filters
total: 33
Catalog Publications
Year 2025
-
UV light-activated gas mixture sensing by ink-printed WS2 layer
PublicationWe fabricated a sensing layer from ink-printed WS2 flakes and utilized it for UV-activated gas sensing. The optical imaging of the structure made by repeated printing revealed the continuous layer comprising sub-µm flakes, confirmed independently by small-area AFM images (1×1 µm2). The activity of the sensing surface was investigated locally via AFM scanning of the surface with a polarized probing tip. The results indicated that...
Year 2024
-
Enhanced visible light-activated gas sensing properties of nanoporous copper oxide thin films
PublicationMetal oxide gas sensors are popular chemoresistive sensors. They are used for numerous tasks, including environmental and safety monitoring. Some gas-sensing materials exhibit photo-induced properties that can be utilized for enhanced gas detection by modifying the sensor selectivity and sensitivity when illuminated by light. Here, we present the gas sensing characteristics of highly nanoporous Cu2O thin films towards both electrophilic...
-
Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing
PublicationWe discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance gas sensing by considering its intensity and the slope of power spectral density. The issues of low-frequency noise measurements in resistive gas sensors, specifically in two-dimensional...
-
Fluctuation-Enhanced Sensing of Organic Vapors by Ink-Printed MoS2 Devices under UV Irradiation
PublicationThis work presents the results of fluctuationenhanced sensing (FES) of selected organic gases by MoS2 sensor fabricated via a simple ink printing method. We demonstrate that low-frequency noise measured under UV irradiation (275 nm) is more sensitive to different gases than measured in the dark. The noise at 1 Hz under UV light increased 3.3, 3.5, 1.6, and 2.9 times for chloroform, tetrahydrofuran, acetonitrile, and acetone ambiances, respectively....
-
UV-assisted fluctuation-enhanced gas sensing by ink-printed MoS2 devices
PublicationIn this work, MoS2 flakes were printed on ceramic substrates and investigated toward 1–10 ppm of nitrogen dioxide (NO2), 2–12 ppm of ammonia (NH3), and 2–12 ppm acetone (C3H6O) under UV light (275 nm). The structure of overlapping MoS2 flakes and UV light assistance affected high responsivity to NO2 when DC resistance was monitored, and superior sensitivity to NH3 was obtained from the low-frequency noise spectra. MoS2 exhibited...
Year 2023
-
Probability distribution of flicker noise in AuNPdecorated graphene–Si Schottky barrier diode
PublicationWe present results of the probability distribution analysis of flicker noise generated in Au nanoparticle (AuNP) decorated graphene–Si Schottky barrier diodes with and without yellow light illumination (592 nm), close to the localized surface plasmon resonance in the AuNPs (586 nm). The AuNPs occupy imperfections in the single-layer graphene and reduce the flicker noise intensity generated in the graphene layer. The estimated probability...
-
The effects of gas exposure on the graphene/AlGaN/GaN heterostructure under UV irradiation
PublicationThis work demonstrates a graphene/AlGaN/GaN sensing device with two-dimensional electron gas (2DEG) toward nitrogen dioxide (NO2), tetrahydrofuran, and acetone detection under UV light irradiation. We propose combining measurements of the DC characteristics with a fluctuation-enhanced sensing method to provide insight into the gas detection mechanisms in the synergistic structure of highly stable GaN and gas-sensitive graphene....
Year 2022
-
Analysis of exhaled breath for dengue disease detection by low-cost electronic nose system
PublicationThis paper presents a procedure and a set-up of an electronic nose system analyzing exhaled breath to detect the patients suffering from dengue – a mosquito-borne tropical disease. Low-power resistive gas sensors (MiCS-6814, TGS8100) were used to detect volatile organic compounds (VOCs) in the exhaled breath. The end-tidal phase of patients exhaled breath was collected with a BioVOCTM breath sampler. Two strategies were assessed...
-
Clinical studies of detecting COVID-19 from exhaled breath with electronic nose
PublicationThe COVID‑19 pandemic has attracted numerous research studies because of its impact on society and the economy. The pandemic has led to progress in the development of diagnostic methods, utilizing the polymerase chain reaction (PCR) as the gold standard for coronavirus SARS‑CoV‑2 detection. Numerous tests can be used at home within 15 min or so but of with lower accuracy than PCR. There is still a need for point‑of‑care tests available...
-
Organic Vapor Sensing Mechanisms by Large-Area Graphene Back-Gated Field-Effect Transistors under UV Irradiation
PublicationThe gas sensing properties of graphene back-gated field-effect transistor (GFET) sensors toward acetonitrile, tetrahydrofuran, and chloroform vapors were investigated with the focus on unfolding possible gas detection mechanisms. The FET configuration of the sensor device enabled gate voltage tuning for enhanced measurements of changes in DC electrical characteristics. Electrical measurements were combined with a fluctuation-enhanced...
Year 2021
-
Embedded gas sensing setup for air samples analysis
PublicationThis paper describes a measurement setup (eNose) designed to analyze air samples containing various volatile organic compounds (VOCs). The setup utilizes a set of resistive gas sensors of divergent gas selectivity and sensitivity. Some of the applied sensors are commercially available and were proposed recently to reduce their consumed energy. The sensors detect various VOCs at sensitivities determined by metal oxide sensors’ technology...
-
Pulsed UV-irradiated Graphene Sensors for Ethanol Detection at Room Temperature
PublicationA graphene-based gas sensor fabricated in a FET (GFET) configuration and its sensitivity towards ethanol and methane is reported. Detection of ethanol at the level of 100 ppm was observed under pulsed UV irradiation and after cleaning by UV light in the N2 ambient. Reduction of the frequency of UV irradiation pulses resulted in increased changes in sensor resistance in the presence of ethanol. Improved sensing behavior was ascribed...
Year 2020
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublicationHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
Exhaled breath analysis by resistive gas sensors
PublicationBreath analysis has attracted human beings for centuries. It was one of the simplest methods to detect various diseases by using human smell sense only. Advances in technology enable to use more reliable and standardized methods, based on different gas sensing systems. Breath analysis requires the detection of volatile organic compounds (VOCs) of the concentrations below individual ppm (parts per million). Therefore, advanced detection...
Year 2018
-
Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors
PublicationThis paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume...
Year 2014
-
Algorytmy przetwarzania widm Ramana w procesie detekcji substancji chemicznych
PublicationRozprawa przedstawia szczegółowo algorytmy, jakie są stosowane podczas przetwarzania widm Ramana, rejestrowanych przenośnym spektrometrem o skończonej rozdzielczości. Pracę podzielono na osiem rozdziałów. W pierwszym określono cel i tezy pracy. Rozdział drugi opisuje podstawowe pojęcia dotyczące zjawiska Ramana oraz zasady budowy urządzeń do pomiarów widm Ramana. W rozdziale trzecim scharakteryzowano błędy występujące podczas pomiarów...
-
Detection of Denatonium Benzoate (Bitrex) Remnants in Noncommercial Alcoholic Beverages by Raman Spectroscopy
PublicationIllegal alcoholic beverages are often introduced into market using cheap technical alcohol, which is contaminated by denatonium benzoate (Bitrex) of very small concentration. Bitrex is the most bitter chemical compound and has to be removed before alcohol consumption. The home-made methods utilize sodium hypochlorite to disintegrate particles of denatonium benzoate in alcohol and to remove bitter taste before trading. In this experimental...
Year 2013
-
Algorytmy przetwarzania widm Ramana podczas detekcji substancji chemicznych
PublicationW pracy zostaną przedstawione algorytmy wstępnego przetwarzania widm mające na celu usunięcie lub zmniejszenie intensywności zakłóceń obecnych w rejestrowanych widmach Ramana, ze szczególnym uwzględnieniem automatyzacji tego procesu (bez konieczności wyboru parametrów przetwarzania przez obsługę urządzenia). Kolejną prezentowaną grupę algorytmów stanowią procedury parametryzacji widm, które opisują widma w postaci zbioru kilku...
-
Metody usuwania zakłóceń podczas pomiarów polowych widm Ramana
PublicationW pracy zostały scharakteryzowane źródła zakłóceń występujące podczas pomiarów widm Ramana w warunkach polowych. Zaprezentowano wpływ czasu integracji na jakość rejestrowanych widm w przypadkach, gdy szumy własne spektrometru mają składową typu 1/f, dominującą w zakresie małych częstotliwości. Przedstawiono także wyniki uzyskane podczas pomiarów z detekcją synchroniczną, stosowaną w przenośnych spektrometrach Ramana, w pomiarach...
-
Metody usuwania zakłóceń podczas pomiarów polowych widm Ramana
PublicationW pracy zostały scharakteryzowane źródła zakłóceń występujące podczas pomiarów widm Ramana w warunkach polowych oraz sposoby redukcji ich wpływu na jakość rejestrowanych widm. Zaprezentowano wpływ czasu integracji na jakość rejestrowanych widm w przypadkach, gdy szumy własne spektrometru mają składową typu 1/f, dominującą w zakresie małych częstotliwości. Przedstawiono także wyniki uzyskane podczas pomiarów z detekcją synchroniczną,...
Year 2011
-
Detection of illicit chemicals by portable Raman spectrometer
PublicationThe Raman spectrometers can be built as the portable devices and can be used in various places to detect illicit chemicals. This method has become popular due to deficiency of other fast methods that could be applied against terrorist attacks or could help police at their work. The conception of a portable Raman spectrometer has been presented. The description enclosures presentation of the prepared device and its possible applications...
-
Portable Raman spectrometer - design rules and applications
PublicationRaman spectroscopy has become more popular due to its new prospective field applications in forensic sciences, war against terrorism, environment protection and other field chemical analysis. Raman spectrometers can be miniaturised to portable devices and their price is decreasing due to development of optoelectronics components. Unfortunately, this technology has still numerous limitations that influence their design and limit...
-
Portable raman spectrometer with two excitation wavelengths
PublicationSelected problems of development of a portable Raman spectrometer having small size, reduced power consumption and robust construction are shown. The device dedicated for semiskilled personnel uses two lasers: 785nm and 355nm. Results of preliminary tests are presented. Also data processing procedures as well as problems referred to Raman signals acquisition through packages and influence of interfering signals are discussed.
-
Raman Spectra Measurements for Chemical Identifications - Aspect of Uncertainty Sources and Reduction of Their Effects
PublicationRaman spectrometers enable fast and non-contact identification of examined chemicals. These devices measure Raman spectra and compare with the spectra database to identify unknown and often illicit chemicals (e.g. drugs, explosives) usually without any sample preparation. Raman spectra measurements are a challenge due to noise and interferences present outside the laboratories (field applications). The design of a portable Raman...
-
The control software of the portable raman spectrometer
PublicationThe paper contains a description of the control software of a portable Raman spectrometer which was built in the Department of Optoelectronics and Electronic Systems Faculty of Electronics, Telecommunications and Informatics Gdansk University of Technology. The software has modular structure, which includes the laser control module and the spectrum acquisition module (laser power selection, working mode and data acquisition time)...
-
The fast identification of explosives, natcotics and other chemicals carried on board of ships or transported in containers
PublicationThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is an advanced technique used in state-of-the art laboratories for fast identification of chemicals. No sample preparation is required, and identification can be carried out through transparent packing, such as plastic or glass,...
Year 2010
-
Algorithms of chemicals detection using raman spectra
PublicationRaman spectrometers are devices which enable fast and non-contact identification of examined chemicals. These devices utilize the Raman phenomenon to identify unknown and often illicit chemicals (e.g. drugs, explosives)without the necessity of their preparation. Now, Raman devices can be portable and therefore can be more widely used to improve security at public places. Unfortunately, Raman spectra measurements is a challenge...
-
Algorytmy wykrywania substancji chemicznych na podstawie pomiarów widm Ramana
PublicationRejestracja widma promieniowania rozproszonego nieelastycznie podczas zjawiska Ramana, które jest charakterystyczne dla badanej substancji, pozwala jej identyfikację. W pracy zostaną opisane błędy wyznaczania widm Ramana, powodujące ograniczenia możliwości identyfikacji substancji chemicznych lub ich mieszanin. Szczegółowo zostaną przedstawione możliwości redukcji błędów pomiarowych przez zastosowanie procedur usuwania tła oraz...
-
Algorytmy wykrywania substancji chemicznych na podstawie pomiarów widm Ramana
PublicationRejestracja widma promieniowania rozproszonego nieelastycznie podczas zjawiska Ramana, które jest charakterystyczne dla badanej substancji, pozwala na jej identyfikację. W pracy zostały przedstawione przykładowe widma Ramana substancji chemicznych. Następnie opisano błędy podczas pomiarów widm Ramana, powodujące ograniczenia możliwości identyfikacji substancji chemicznych lub ich mieszanin. Szczegółowo przedstawiono możliwości...
-
Budowa i oprogramowanie przenośnego spektrometru ramana
PublicationW pracy przedstawiono budowę oraz zasadę działania przenośnego spektrometru Ramana, przygotowywanego w Katedrze Optoelektroniki i Systemów Elektronicznych Politechniki Gdańskiej. Opisano format plików *.SPC, który jest wykorzystywany przez oprogramowanie sterujące budowanym spektrometrem oraz stosowany przez większość komercyjnych aplikacji przeznaczonych do analizy widm Ramana. Przedstawiono podstawowe metody parametryzacji rejestrowanych...
-
BUDOWA I OPROGRAMOWANIE PRZENOŚNEGO SPEKTROMETRU RAMANA
PublicationW pracy przedstawiono budowę oraz zasadę działania przenośnego spektrometru Ramana, przygotowywanego w Katedrze Optoelektroniki i Systemów Elektronicznych Politechniki Gdańskiej. Opisano format plików *.SPC, który jest wykorzystywany przez oprogramowanie sterujące budowanym spektrometrem oraz stosowany przez większość komercyjnych aplikacji przeznaczonych do analizy widm Ramana. Przedstawiono podstawowe metody parametryzacji rejestrowanych...
-
Portable raman spectrometer for maritime security applications
PublicationThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is widely used for fast identification of various chemicals. Continuous progress in the field of photonics has resulted in commercial availability of low-power compact Raman spectrometers which can be integrated into portable systems....
-
Raman miniaturised system for field applications
PublicationRaman spectroscopy is a powerful and versatile research technique with a broad range of potential applications, which includes laboratory studies, on-line industrial process monitoring and field measurements. Scope of the field applications includes environment monitoring, detection of dangerous or prohibited materials and rapid identification of unknown samples. It stimulates development of dedicated Raman measurement equipment...
seen 1641 times