Modyfikowane nanodiamentowe warstwy do sensorów z detekcją optyczną i elektrochemiczną
PublicationW rozprawie doktorskiej przedstawiono opracowanie parametrów procesów syntezy osadzania z fazy gazowej wspomaganego plazmą mikrofalową (MWPACVD) do wytwarzania warstw nanodiamentowych o niskim współczynniku absorpcji optycznej i wysokiej przewodności elektrycznej. Warstwy te są przeznaczone do sensorów z detekcją optyczną i elektrochemiczną stosowanych w układzie interferometru Mach-Zehndera do badania in situ modyfikacji elektrod...
-
Noise sources in Raman spectroscopy of biological objects
PublicationWe present an overview of noise sources deteriorating the quality of the recorded biological Raman spectra and the ability to determine the specimen composition. The acquired Raman spectra exhibit intense additive noise components or drifts because of low intensity of the scattered light. Therefore we have to apply expensive or bulky measurement setups to limit their inherent noise or to apply additional signal processing to reduce...
-
Non-Gaussian Resistance Fluctuations in Gold-Nanoparticle-Based Gas Sensors: An Appraisal of Different Evaluation Techniques
PublicationVolatile organic compounds, such as formaldehyde, can be used as biomarkers in human exhaled breath in order to non-invasively detect various diseases, and the same compounds are of much interest also in the context of environmental monitoring and protection. Here, we report on a recently-developed gas sensor, based on surface-functionalized gold nanoparticles, which is able to generate voltage noise with a distinctly non-Gaussian...
-
On the use of a charge balancing method for low energy measurements
PublicationThe paper presents the method for the estimation of the energy consumption of the low-power microcontroller-based devices. Due to high dynamics of the changes of the supply current of the tested devices during the operational cycle, the consumed energy estimation is not easy. In order to avoid disadvantages of known methods, the charge balancing method was employed similarly like in some types of A/D converters.
-
Optical properties of thin TiO2 film deposited on the fiber optic sensor head
PublicationThe presented study was focused on investigation of the titanium dioxide (TiO2) thin film deposited on the fiber tip. The intention of this investigation was using TiO2 film in the construction of the optical fiber sensor head. In the demonstrated construction TiO2 thin layer was deposited on the tip of a commonly used telecommunication single mode optical fiber (SMF-28) by means of the Atomic Layer Deposition (ALD). Thickness...
-
Plasma-Based Deposition and Processing Techniques for Optical Fiber Sensing
PublicationPlasma-based techniques are widely applied for well-controlled deposition, etching or surface functionalization of a number of materials. It is difficult to imagine fabrication of novel microelectronic and optoelectronic devices without using plasma-enhanced deposition of thin films, their selective etching or functionalization of their surfaces for subsequent selective binding of chemical or biological molecules. Depending on...
-
Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation
PublicationIn brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and...
-
Scalable Measurement System for Multiple Impedance Gas Sensors
PublicationAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...
-
Simulating propagation of coherent light in random media using the Fredholm type integral equation
PublicationStudying propagation of light in random scattering materials is important for both basic and applied research. Such studies often require usage of numerical method for simulating behavior of light beams in random media. However, if such simulations require consideration of coherence properties of light, they may become a complex numerical problems. There are well established methods for simulating multiple scattering of light (e.g....
-
Stability of thin film diamond mirror for applications in interferometers under the short-time exposure on selected aggressive chemicals
PublicationIn presented study a thin boron-doped diamond film was proposed for application in the interferometry as a highly durable optical mirror. The unique properties of the diamond films, like high chemical stability and hardness, allow them to be used even in the chemically aggressive environment, where the commonly used silver mirrors can be susceptible to damage. The investigated nanodiamond layer was fabricated by uPE CVD method...
-
System automatyzacji przeprowadzania i oceniania sprawdzianów studenckich
PublicationArtykuł prezentuje system pozwalający na przeprowadzenie sprawdzianów studenckich w wersji papierowej oraz na komputerach. Kluczowym aspektem systemu jest moduł umożliwiający przeprowadzenie oraz sprawdzenie tradycyjnego testu, którego pytania będą losowane z utworzonej wcześniej bazy (lub kilku baz) pytań. Trzema głównymi zadaniami aplikacji są następująco: tworzenie i edycja testów oraz zapisywanie ich w bazie pytań, generowanie...
-
System do pomiaru szumów elementów optoelektronicznych w szerokim zakresie prądów
PublicationW artykule zostanie zaprezentowany opis systemu pomiarowego zawierającego zaprojektowaną głowicę pomiarową do pomiarów szumów generowanych przez elementy optoelektroniczne. Przedstawione zostaną wyniki testów funkcjonowania systemu pomiarowego dla diod LED dla prądu wynoszącego ID = 2 mA. Pomiar odbywał się w zakresie małych częstotliwości czyli do 1 kHz. Głowica pomiarowa została zbudowana w sposób minimalizujący wpływ zakłóceń zewnętrznych...
-
System monitoringu pomieszczeń zamkniętych oparty na zespole kamer internetowych
PublicationArtykuł opisuje system do monitoringu pomieszczeń zamkniętych oparty na zespole kamer internetowych. System umożliwia rejestrację obrazu za pomocą trzech kamer internetowych w momencie wykrycia ruchu i przekazuje w czasie rzeczywistym nagrany film użytkownikowi na dowolne urządzenie posiadające system Android. Dzięki takiemu rozwiązaniu można kontrolować dane pomieszczenie np. pokój dziecka, biuro czy też sklep. Umożliwia to podjęcie...
-
Tailoring the optical parameters of optical fiber interferometer with dedicated boron-doped nanocrystalline diamond thin film
PublicationOptical fiber interferometer using nanocrystalline boron-doped diamond film was investigated. The diamond films were deposited on glass plates using a Microwave Plasma-Enhanced Chemical Vapour Deposition (μPE CVD) sys-tem. The growth time was 3h, with boron doping level of 10 000 ppm producing films (B-NCD-10) of thickness ~ 200 nm. The presence of boron atoms in the diamond film is evident in Raman spectrum as peaks at 1212 cm-1...
-
The silver layers in fiber-optic sensors
PublicationIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
Zastosowanie statystyki Bayesowskiej do uzasadnienia zmiany sposobu obliczania standardowej niepewności pomiaru
PublicationCelem pracy jest wyjaśnienie powodu, dla którego Wspólny Komitet ds. Przewodników w Metrologii (JCGM) wprowadza zmianę sposobu obliczania standardowej niepewności pomiaru. Modyfikacja ma obowiązywać w nowej wersji przewodnika Guide to the Expression of Uncertainty in Measurement (GUM). Rozważania w artykule są oparte na przykładzie oceny niepewności pomiaru metodą typu A, z zastosowaniem statystyki Bayesowskiej w formie eksperymentów...
Year 2016
-
A concept of measurement system based on the Z-Wave standard
PublicationIn the paper a new concept of measurement system based on the Z-Wave standard is presented. This standard is dedicated to use mainly in home automation systems, but its properties enable to use it in dispersed measurement systems and support wireless communication between measurement nodes in a mesh-type network. In the paper basic metrological aspects of the Z-Wave standard and an example of impedance measurement system are discussed.
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublicationA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
A testing method of analog parts of mixed-signal electronic systems equipped with the IEEE1149.1 test bus
PublicationA new solution of the JTAG BIST for testing analog circuits in mixed-signal electronic microsystems controlled by microcontrollers and equipped with the IEEE1149.1 bus is presented. It is based on a new fault diagnosis method in which an analog circuit is stimulated by a buffered signal from the TMS line, and the time response of the circuit to this signal is sampled by the ADC equipped with the JTAG. The method can be used for...
-
An Implementation of a Compact Smart Resistive Sensor Based on a Microcontroller with an Internal ADC
PublicationIn the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and the resistive sensor connected in parallel with an interference suppression capacitor. The measurement...
-
Analiza impedancji sieci prądu stałego w instalacjach fotowoltaicznych
PublicationDokonano analizy impedancji sieci prądu stałego w instalacji fotowoltaicznej. Analizę tę przeprowadzono pod względem predykcji charakterystyki zaburzeń elektromagnetycznych generowanych przez instalacje PV. Badania przeprowadzono zarówno dla zaburzeń różnicowych, jak i wspólnych. Zastosowano podejście analityczne - wykorzystując teorię linii długiej oraz pomiary wykonane na stanowisku laboratoryjnym.
-
ANALYSIS OF EFFECTIVENESS AND COMPUTATIONAL COMPLEXITY OF TREND REMOVAL METHODS
PublicationThe paper presents a method of processing measurement data due to remove slowly varying component of the trend occurring in the recorded waveforms. Comparison of computational complexity and trend removal efficiency between some commonly used methods is presented. The impact of these procedures on probability distribution and power spectral density is shown. Effectiveness and computational complexity of these methods depend essentially...
-
Annealing of indium tin oxide (ITO) coated optical fibers for optical and electrochemical sensing purposes
PublicationGlass and fiber structures with Indium Tin Oxide (ITO) coating were subjected to annealing in order to identify impact of the thermal treatment on their optical and electrochemical properties. It is shown that the annealing process significantly modifies optical properties and thickness of the films, which are crucial for performance of optical fiber sensors. Moreover, it visibly improves electrochemical activity of ITO on glass...
-
Anti-theft lab security system based on RFID
PublicationThe aim of the project is to design and create an electronic system, which can be used to protect laboratory equipment against theft. The main task of the system is to warn a person responsible for the facilities about any attempts made to steal equipment from a laboratory. In a case of an alarm situation, the system emits a sound signal. The concept of the anti-theft security system based on RFID was developed on the basis of...
-
Application of boron-doped diamond film and ZnO layer in the Fabry-Pérot interferometer
PublicationIn this article there have been presented the use of boron-doped diamond films for sensor applications. The low-finesse Fabry-Pérot interferometer working in the reflective mode has been implemented. Two kinds of reflective layers have been elaborated: boron-doped diamond thin films and zinc-oxide (ZnO) layer. Thin ZnO layers were deposited by Atomic Layer Deposition (ALD) on the face of a standard telecommunication single-mode...
-
APPLICATION OF INFRARED THERMOGRAPHY TO NON-CONTACT TESTING OF AD/DC POWER SUPPLY
PublicationTesting of AC/DC power supplies using the thermography was carried out in order to assess their assembly and operation correctness before launching them on the market. The investigation was carried out for 17 AC/DC power supplies which passed the standard tests (measurements of their basic parameters and characteristics). The investigation consisted of two steps. In the first step the dispersion of temperature on power supply boards...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublicationThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers
PublicationIn this paper we investigated the response of a fiber-optic Fabry-Pérot sensing interferometer with thin ZnO layers deposited on the end faces of the optical fibers forming the cavity. Standard telecommunication single-mode optical fiber (SMF-28) segments were used with the thin ZnO layers deposited by Atomic Layer Deposition (ALD). Measurements were performed with the interferometer illuminated by two broadband sources operating...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublicationLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
Blood equivalent phantom vs whole human blood, a comparative study
PublicationPreclinical research of biomedical optoelectronic devices is often performed with the use of blood phantoms — a simpli¯ed physical model of blood. The aim of this study is the comparison and distinction between blood phantoms as well as whole human blood measurements. We show how the use of such phantoms may in°uence the incorrect interpretation of measured signal. On the other hand, we highlight how the use of blood phantoms enables...
-
Coherent-wave Monte Carlo method for simulating light propagation in tissue
PublicationSimulating propagation and scattering of coherent light in turbid media, such as biological tissues, is a complex problem. Numerical methods for solving Helmholtz or wave equation (e.g. finite-difference or finite-element methods) require large amount of computer memory and long computation time. This makes them impractical for simulating laser beam propagation into deep layers of tissue. Other group of methods, based on radiative...
-
Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
PublicationThe aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development...
-
Detection of gaseous compounds with different techniques
PublicationSensing technology has been developed for detection of gases in some environmental, industrial, medical, and scientific applications. The main tasks of these works is to enhance performance of gas sensors taking into account their different applicability and scenarios of operation. This paper presents the descriptions, comparison and recent progress in some existing gas sensing technologies. Detailed introduction to optical sensing...
-
Diamond-based protective layer for optical biosensors
PublicationOptical biosensors have become a powerful alternative to the conventional ways of measurement owing to their great properties, such as high sensitivity, high dynamic range, cost effectiveness and small size. Choice of an optical biosensor's materials is an important factor and impacts the quality of the obtained spectra. Examined biological objects are placed on a cover layer which may react with samples in a chemical, biological...
-
Distributed measurement system with data transmission secured using XXTEA algorithm
PublicationThe paper deals with wireless data transmission security in the distributed measurement and control system. An overview of cryptographic algorithms was presented paying special attention to the algorithm dedicated to units with low processing power, which is important due to minimization of energy consumption. Measurement modules equipped with simple microcontrollers send data wirelessly to the central unit. The transmission was...
-
Electrical characterization of diamond/boron doped diamond nanostructures for use in harsh environment applications
PublicationThe polycrystalline boron doped diamond (BDD) shows stable electrical properties and high tolerance for harsh environments (e.g. high temperature or aggressive chemical compounds) comparing to other materials used in semiconductor devices. In this study authors have designed electronic devices fabricated from non-intentionally (NiD) films and highly boron doped diamond structures. Presented semiconductor devices consist of highly...
-
Electrochemically assisted deposition of hydroxyapatite on Ti6Al4V substrates covered by CVD diamond films — Coating characterization and first cell biological results
PublicationAlthough titaniumand its alloys are widely used as implant material for orthopedic and dental applications they show only limited corrosion stability and osseointegration in different cases. The aim of the presented research was to develop and characterize a novel surface modification system from a thin diamond base layer and a hydroxyapatite (HAp) top coating deposited on the alloy Ti6Al4V widely used for implants in contact with bone....
-
Ellipse-fitting algorithm implementation in the impedance measurement system based on DAQ card with FPGA
PublicationThe paper presents an implementation of the ellipse-fitting algorithm in the impedance measurement system based on DAQ card equipped with FPGA chip. The method implementation was tested by simulation means as well as experimentally in the designed and presented measurement system. Finally, the limit values of sampling parameters which assures satisfying accuracy were given.
-
Ellipsometric investigation of nitrogen doped diamond thin films grown in microwave CH4/H2/N2 plasma enhanced chemical vapor deposition
PublicationThe influence of N2 concentration (1%–8%) in CH4/H2/N2 plasma on structure and optical properties of nitrogen doped diamond (NDD) films was investigated. Thickness, roughness, and optical properties of the NDD films in the VIS–NIR range were investigated on the silicon substrates using spectroscopic ellipsometry. The samples exhibited relatively high refractive index (2.6 6 0.25 at 550 nm) and extinction coefficient (0.05 6 0.02...
-
Energy consumption estimation of low-power devices using an integrating coulombmeter
PublicationThe main problem in designing devices powered with Energy Harvesting is an estimation of energy demand of low-power devices as well as quantity of energy provided by the selected energy transducer in the assumed work conditions. Due to the work characteristic of each block of the device and properties of the measured signal, measurement is not trivial. The paper presents the proposal of the micro-charge measurement device based...
-
Ewaluacja jakości kształcenia w kadecji 2012-2016, podsumowanie i wnioski
Publicationprzedstawiono działalność Uczelnianej Komisji ds. Jakości Kształcenia w czasie kadencji 2012-2016
-
Experimental results of full scattering profile from finger tissue-like phantom
PublicationHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. We suggest a new optical method for sensing physiological tissue state, based on the collection of the ejected light at all exit angles, to receive the full scattering profile. We built a unique set-up for noninvasive encircled measurement. We use a laser, a photodetector and finger tissues-mimicking phantoms presenting different optical...
-
Fabrication and characterization of boron-doped nanocrystalline diamond-coated MEMS probes
PublicationFabrication processes of thin boron-doped nanocrystalline diamond (B-NCD) films on silicon-based micro- and nano-electromechanical structures have been investigated. Nanocrystalline boron doped -diamond (B-NCD) films were deposited using Microwave Plasma Assisted Chemical Vapour Deposition (MW PA CVD) method. The variation of B-NCD morphology, structure and optical parameters were particularly investigated. The use of truncated...
-
Fabrication and characterization of composite TiO2 nanotubes/ boron-doped diamond electrodes towards enhanced supercapacitors
PublicationThe composite TiO2 nanotubes / boron-doped diamond electrodes were deposited using Microwave Plasma Enhanced Chemical Vapor Deposition resulting in the improved electrochemical performance. This composite electrode can deliver high specific capacitance of 7.46 mF cm‐− 2 comparing to boron-doped diamond (BDD) deposited onto flat Ti plate (0.11 mF cm‐− 2).The morphology and composition of composite electrode were characterized...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublicationIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
Fiber optic low-coherence Fabry-Pérot interferometer with ZnO layers in transmission and reflective mode: comparative study
PublicationA construction of a low-coherence fiber-optic Fabry-Pérot interferometer using a thin ZnO layer as a reflective surfaces was proposed and examined. In the investigated setup, the ZnO layer of thickness 200 nm were deposited on the face of the standard telecommunication single-mode optical fiber (SMF-28). Measurements of interference signal were performed for the interferometer working in the transmission and reflective mode, as...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublicationThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
Fluctuation enhanced gas sensing with WO3-based nanoparticle gas sensors modulated by UV light at selected wavelengths
PublicationThe sensitivity and selectivity of WO3-based gas sensors can be enhanced by UV-irradiation-induced modulation, especially if different wavelengths are employed. We used fluctuation-enhanced gas sensing, based on measurements of resistance fluctuations in the gas sensor, to study the effects of such modulation on the noise intensity for ambient atmospheres of synthetic air without and with additions of small amounts of ethanol,...
-
Fluctuation-Enhanced Sensing with Organically Functionalized Gold Nanoparticle Gas Sensors Targeting Biomedical Applications
PublicationDetection of volatile organic compounds is a useful approach to non-invasive diagnosis of diseases through breath analysis. Our experimental study presents a newly developed prototype gas sensor, based on organically-functionalized gold nanoparticles, and results on formaldehyde detection using fluctuation-enhanced gas sensing. Formaldehyde was easily detected via intense fluctuations of the gas sensor’s resistance, while the cross-influence...
-
Gas Detection Using Resistive Gas Sensors And Radial Basis Function Neural Networks
PublicationWe present a use of Radial Basis Function (RBF) neural networks and Fluctuation Enhanced Sensing (FES) method in gas detection system utilizing a prototype resistive WO3 gas sensing layer with gold nanoparticles. We investigated accuracy of gas detection for three different preprocessing methods: no preprocessing, Principal Component Analysis (PCA) and wavelet transformation. Low frequency noise voltage observed in resistive gas...