prof. dr hab. inż. Jerzy Wtorek
Employment
- Professor at Department of Biomedical Engineering
Research fields
Publications
Filters
total: 144
Catalog Publications
-
Color transformation methods for dichromats
PublicationColor blindness is a serious perception problem. Suffering individuals cannot understand messages, which are carrying by many images, especially those, distributed by WWW. In this paper we are proposing three image processing methods to enhance image recognition and understanding by persons with dichromacy. Color difference image is introduced to represent color perception dissimilarity. Two color transformation methods are presented....
-
The contribution of blood-flow-induced conductivity changes to measured impedance
PublicationW pracy rozwazane sa zmiany przewodnosci zachodzace w anizotropowym osrodku i ich wplyw na mierzona rezystancje. Uzyskano to za pomoca rozszerzenia wzoru Geselowizta na przypadki anizotropowe. Wykazano, ze tylko te skladowe zmian przewodnosci wplywaja na mierzona rezystancje, dla ktorych odpowiadajacy im skladnik pola eklektrycznego byl niezerowy.Wyniki te zastosowanu do zmian rezystywnosci wywolanych zmiananmi przewodnosci plynacej...
-
Impact of slow breathing on the blood pressure and subarachnoid space width oscillations in humans
PublicationThe aim of the study was to assess cardiac and respiratory blood pressure (BP) and subarachnoid space (SAS) width oscillations during the resting state for slow and fast breathing and breathing against inspiratory resistance. Experiments were performed on a group of 20 healthy volunteers (8 males and 12 females; age 25.3 ± 7.9 years; BMI = 22.1 ± 3.2 kg/m2). BP and heart rate (HR) were measured using continuous finger-pulse photoplethysmography....
-
A multisensor detector of a sleep apnea for using at home
PublicationDiagnosis of obstructive sleep apnea usually involves polysomnographic analysis, which unfortunately requires overnight stay in a specialized clinic and is very uncomfortable for a patient. This paper describes the method and apparatus for recording a set of signals to detect sleep apnea. The device records the following signals simultaneously: three-channel ECG, respiratory functions, signals from the accelerometer, and snoring...
-
Eye-mouse for disabled
PublicationW pracy przedstawiono projekt urządzenia umożliwiającego komunikację z komputerem za pomocą ruchów gałki ocznej osobom niepełnosprawnym
-
Interactions with recognized objects
PublicationImplicit interaction combined with object recognition techniques opens a new possibility for gathering data and analyzing user behavior for activity and context recognition. The electronic eyewear platform, eGlasses, is being developed, as an integrated and autonomous system to provide interactions with smart environment. In this paper we present a method for the interactions with the recognized objects that can be used for electronic...
-
Pose classification in the gesture recognition using the linear optical sensor
PublicationGesture sensors for mobile devices, which have a capability of distinguishing hand poses, require efficient and accurate classifiers in order to recognize gestures based on the sequences of primitives. Two methods of poses recognition for the optical linear sensor were proposed and validated. The Gaussian distribution fitting and Artificial Neural Network based methods represent two kinds of classification approaches. Three types...
-
Head movement compensation algorithm in multi-display communication by gaze
PublicationAn influence of head movements on the gaze estimation accuracy when using a head mounted eye tracking system is discussed in the paper. This issue has been examined for a multi-display environment. It was found that head movement (rotation) to some extent does not influence on the gaze estimation accuracy seriously. Acceptable results were obtained when using eye-tracker to communicate with a computer via in two displays simultaneously.
-
Gaze tracking in multi-display environment
PublicationThis paper presents the basic ideas of eye and gaze tracking in multiple-display environment. The algorithm for display detection and identification is described as well as the rules for gaze interaction in multi display environment. The core of the method is to use special LED markers and eye and scene tracking glasses. Scene tracking camera registers markers position which is then represented as a cloud of points. Analyzing the...
-
Septic safe interactions with smart glasses in health care
PublicationIn this paper, septic safe methods of interaction with smart glasses, due to the health care environment applications consideration, are presented. The main focus is on capabilities of an optical, proximity-based gesture sensor and eye-tracker input systems. The design of both interfaces is being adapted to the open smart glasses platform that is being developed under the eGlasses project. Preliminary results obtained from the...
-
Monitoring of a bathing person
PublicationW pracy przedstawiono koncepcję i wstępne wyniki układu pozwalającego na monitorowanie stanu i aktywności osoby kąpiącej się. Zaprezentowany system pozwala na wykrycie osoby kąpiącej się w wannie, analizę jej aktywności oraz detekcję stanów potencjalnie niebezpiecznych. W artykule pokazano metodę pomiaru, dokonano analizy czułości, zaprezentowano prototyp układu pomiarowego i wyniki wstępnych pomiarów.
-
Comparison of active proximity radars for the wearable devices
PublicationTwo methods of object position and movement estimation in relation to the user of smart glasses were investigated. An active infrared and ultrasonic methods of the obstacle detection were presented and compared. Application of these methods depend on active transducers type (physical medium used), geometry and surface properties of detected objects and their movement direction and speed. In the article properties of both detectors...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublicationUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Multimodal Platform for Continuous Monitoring of the Elderly and Disabled
Publication,
-
Gaze pattern lock for elders and disabled
Publication...
-
Computerized Color Processing for Dichromats
PublicationArtykuł przedstawia opis metod w zakresie symulacji kolorów postrzeganych przez osoby z dichromacją oraz metod rozpoznawania kolorów jak i etykietowania kolorów w obrazach cyfrowych.
-
Complex human computer interface for las patient
PublicationW pracy zaprezentowano system umożliwiający komunikację osobie sparaliżowanej z komputerem przy pomocy wzroku.
-
Detection of person presence and its activity in the bathtub
PublicationA practical application of a bioimpedance technique for a detection of a bathing person is presented in the paper. It addresses the possibility of supervising people in the bathtub without voiding of their intimacy. The measurement system installed in a fiber-glass or a plastic bathtub is able to detect a presence of the bathing person, to estimate its activity and thus to detect potentially dangerous events. In the paper a principle...
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublicationW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
seen 2983 times