Filters
total: 3536
-
Catalog
displaying 1000 best results Help
Search results for: UNCERTAINTY OF MEASUREMENT, TECHNICAL METHOD, MEASUREMENT OF RESISTANCE
-
Electrochemical sensor for measurement of volatile organic compounds = Elektrochemiczny czujnik do oznaczania lotnych związków organicznych
PublicationPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania benzaldehydu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako technikę detekcyjną woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym były ciecze jonowe: chlorek 1-heksylo,3- metyloimidazolinowy i bis(trifluorometylosulfonylo)imidek...
-
Topological model of aptitude of the measurement circuits of main subassemblies of an internal combustion engine crankshaft-piston assembly
PublicationThe paper presents a topological model allowing to determine the probability of aptitude of the diagnosing system (SDG) individual measuring circuits and also to determine to what degree they influence the assessment of the technical condition of an arbitrary main subassembly of crankshaft-piston assemblies as a diagnosed system (SDN).
-
Selection of Methods of Surface Texture Characterisation for Reduction of the Frequency-Based Errors in the Measurement and Data Analysis Processes
Publication -
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Design of a Distributed System using Mobile Devices and Workflow Management for Measurement and Control of a Smart Home and Health
PublicationThe paper presents design of a distributed system for measurements and control of a smart home including temper- atures, light, fire danger, health problems of inhabitants such as increased body temperature, a person falling etc. This is done by integration of mobile devices and standards, distributed service based middleware BeesyCluster and a workflow management system. Mobile devices are used to measure the parameters and are...
-
A new scuffing shock test method for the determination of the resistance to scuffing of coated gears
Publication -
Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis
Journals -
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Fast High-Impedance Spectroscopy Method Using SINC Signal Excitation
PublicationIn this paper the method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 Gohm) is evaluated by means of simulation and practical experiment. The method is based on excitation of an object with a sinc signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance spectrum is obtained with use of continuous Fourier transform...
-
Internet Measurement Conference
Conferences -
Szacowanie niepewności pomiarowej układu do diagnostyki łożysk opartej na analizie mocy chwilowej
PublicationW artykule przedstawiono sposób szacowania niepewności układu pomiarowego, składającego się z dzielnika napięcia oraz bocznika, który wykorzystano do badań diagnostycznych łożysk silników indukcyjnych. Wyniki analizy metrologicznej pozwalają sprecyzować, jakiej niepewności pomiarowej można się spodziewać, dokonując badań diagnostycznych łożysk silników indukcyjnych w określonych warunkach, na stanowisku badawczym metodą...
-
Visual method for detecting critical damage in railway contact strips
PublicationEnsuring an uninterrupted supply of power in the electric traction is vital for the safety of this important transport system. For this purpose, monitoring and diagnostics of the technical condition of the vehicle's power supply elements are becoming increasingly common. This paper presents a new visual method for detecting contact strip damage, based on measurement and analysis of the movement of the overhead contact line (OCL)...
-
Maciej Jerzy Głowacki
PeopleMaciej Jerzy Głowacki is an alumnus of the Gdańsk University of Technology. He graduated with honors from the Faculty of Mechanical Engineering (B.Eng., 2017) and the Faculty of Electronics, Telecommunications and Informatics (M.S., 2018). Since 2014 he has been continuously actively involved in a research carried out at the Department of Metrology and Optoelectronics. His scientific activities include a deposition of antibacterial...
-
Atmospheric Measurement Techniques
Journals -
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Temperature measurement using NIR camera with automatic adjustment of integration time for monitoring high-temperature industrial processes
Publication -
The influence of a strong external magnetic field from a permanent magnet on a measurement accuracy of an inductive watt-hour meter
Publication -
Urgent need to address quality control issues of out‐of‐office blood pressure measurement and patient risk assessment
Publication -
MEASUREMENT OF EFFICIENCY OF DIDACTIC ACTIVITIES OF PUBLIC UNIVERSITIES OF TECHNOLOGY IN POLAND: DIRECTIONAL DISTANCE FUNCTION WITH UNDESIRABLE OUTPUT APPROACH
Publication -
Measurement of efficiency education in public higher education institutions not subject to the supervision of the ministry of science and higher education in Poland
Publication -
Improving the Quality of Magnetic Signature Reproduction by Increasing Flexibility of Multi-Dipole Model Structure and Enriching Measurement Information
PublicationThe paper presents the construction of a multi-dipole model that allows reproducing magneticsignatures of ferromagnetic objects. The virtual object used in the paper is an ellipsoid, which is the sourceof synthetic data. To make the situation more realistic, noise is added to the synthetic data. Two significantimprovements compared to previous work are presented. Three-axial magnetometers are introduced insteadof uniaxial magnetometers....
-
Comparison of different measurement methods of odour and odorants used in the odour impact assessment of wastewater treatment plants in Poland
Publication -
An approach to adaptive beamforming in measurement of EEG.Proceedings 2nd European Medical and Biological Engineering Conference.EMBEC´02.Pt.2
PublicationPotencjały wywołane są wykorzystywane w diagnostyce narządów zmysłu. Ze względu na niski SNR wymagana jest wielokrotne powtarzanie stymulacji i uśrednianie wyników. Prowadzi to do zwielokrotnienia czasu badania. SNR może zostać poprawiony przy użyciu matrycy sensorów. Są one wykorzystane do śledzenia źródeł sygnału. W publikacji przedstawiono dwie metody adaptacyjnego poprawania współczynnika SNR.
-
Comparison of noise reduction methods in radiometric correlation measurements of two-phase liquid-gas flows
PublicationTwo-phase liquid-gas flows occur frequently in the mining, energy, chemical, and petrochemical industries. One of non-contact methods used to analyse these flows is the gamma ray absorption method. However, the signals received from radiation detectors contain a significant stochastic noise, which makes them difficult to analyse. The article describes four methods of noise reduction in cross-correlation measurements of water-air...
-
Light transmission measurement through the fluidized bed photoreactor
Open Research DataDataset contains light transmission measurements through the fluidized bed photoreactor. Two sources of light were used: UV-LEDs and UV fluorescent. Measurements were performed at different air flows: 0, 80, 160 and 240 ml/min. The detailed measurement and equipment data was described in measurment info.txt file.
-
Current divider-based nanosecond high current pulse measuring systems
PublicationThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Measurement of the tram rail profile during a year of operation
Open Research DataThe aim of the work was to analyze the wear of rails during operation and to analyze the supplementation of heavy metals in the soil around the tram route, originating from wearing out rails and tram wheels.The dataset contains measurements of rail head coordinates in 9 research sections made in 8 measurement series. The wear of the rails in selected...
-
Distance measurement by the low coherent interferometer
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Measurement of Unwanted Thought Suppression Strategies with the Thought Control Questionnaire in the General Polish Population: A Confirmatory Factor Analysis and Validation
Publication -
Image Processing of Mg-Al-Sn Alloy Microstructures for Determining Phase Ratios and Grain Size and Correction with Manual Measurement
Publication -
Elective surgery system strengthening: development, measurement, and validation of the surgical preparedness index across 1632 hospitals in 119 countries
Publication -
Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of bang polymer gel dosimeters
Publication -
Investigation of RH effect on uncommon limonene ozonolysis products and SOA formation in indoor air with real time measurement techniques
PublicationScientific interest in SOA influence on indoor air quality increases since last 20 years. It is well known, that particles of nano-sized diameter pose a threat for human health causing, among others: eye, upper airway irritation, inflammatory response in cells, worsening asthma, hypertension, diabetes, and central nervous dysfunction. Terpenes are reactive VOCs, commonly emitted in indoor air and considered to be SOA precursors...
-
A new analyzer based on pellistor sensor with neural network data postprocessing for measurement of hydrocarbons in lower explosive limit range
PublicationW pracy przedstawiono rezultaty pierwszego etapu badań nad nowym typem analizatora do oznaczania stężenia wodoru i lotnych węglowodorów w zakresie dolnej granicy wybuchowości. Analizator ten zbudowano w oparciu o pojedynczy czujnik pelistorowy z układem przetwarzania danych wykorzystującym sztuczną sieć neuronową.
-
Adsorption and desorption of N2 measurement of MXenes catalysts
Open Research DataData contain results from adsorption and desorption of N2 measurement of the Ti3C2Tx MXenes produced via acidic etching aluminum from MAX Phase (Ti3C2-Al-Ti3C2-Al-Ti3C2) using different etching agents, HF/HCl and HF/H2SO4 with different weight ratios (1:3, 1:4, and 1:5). The samples were labeled as MXene HF/HCl X:Y and MXene HF/H2SO4 X:Y, where X:Y...