displaying 1000 best results Help
Search results for: IONIC LIQUIDS SURFACE ACTIVITY MICELLES FORMATION PHASE TRANSFER CATALYSIS
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010788981]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 67 - Tissue image [7100730013398681]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 68 - Tissue image [710073001339961]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7040247104964541]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010782411]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010786271]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010783121]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010789931]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010788701]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 67 - Tissue image [7100730013394201]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 68 - Tissue image [7100730013391341]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010788011]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010784861]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010784821]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 68 - Tissue image [7100730013393011]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 68 - Tissue image [7100730013393191]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 67 - Tissue image [7100730013396351]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 68 - Tissue image [7100730013391331]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 68 - Tissue image [7100730013397491]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 67 - Tissue image [7100730013396541]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 67 - Tissue image [7100730013395211]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 67 - Tissue image [7100730013391071]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 67 - Tissue image [7100730013393931]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Solid papillary carcinoma with invasion - Female, 45 - Tissue image [7010730010783201]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Projektowanie, synteza i charakterystyka fotokatalizatorów nowej generacji na bazie związku Ti3C2Tx do usuwania aktywnych substancji farmaceutycznych
PublicationCelem niniejszej pracy było zastosowanie materiałów nowej generacji na bazie związku Ti3C2Tx w procesach fotokatalitycznej degradacji aktywnych substancji farmaceutycznych: karbamazepiny, acetaminofenu i ibuprofenu. Zakres prac badawczych obejmował syntezę fotokatalizatorów, charakterystykę ich właściwości fizykochemicznych, oraz ocenę aktywności fotokatalitycznej. Przedstawiono możliwość zastosowania węglika tytanu jako kokatalizatora...
-
Effect of particle size of aluminosilicate microspheres on the change of hydration heat of cement mortars and selected physical, chemical, and mechanical properties.
Open Research DataThis subject of the work is the study of selected properties of cement mortars containing two fractions of aluminosilicate microspheres with grain size in the range of 125 to 250 μm and from 250 to 500 μm. Mortar mixtures with ordinary Portland cement (OPC 42.5R) and three substitution rates of cement by microspheres, 1.5%, 3.5%, and 5.0%, were investigated....
-
Modelowanie procesu wrzenia i kondensacji w rozszerzonym zakresie ciśnień zredukowanych
PublicationNiniejsza rozprawa doktorska ma na celu pokazanie wpływu uwzględnienia ciśnienia zredukowanego w analizowanym modelu opisują-cym współczynnik przejmowania ciepła na zbieżność z danymi eksperymentalnymi.Przedmiotem analizy jest półempiryczny model Mikielewicza w zastosowaniu do danych eksperymentalnych w kanałach konwencjonalnych i o małej średnicy płynów uznanych za perspektywiczne.W ramach realizowanych prac badawczych pozyskano...
-
Collision Strengths of Astrophysical Interest for Multiply Charged Ions
PublicationThe electron impact excitation and ionization processes are crucial for modeling the spectra of different astrophysical objects, from atmospheres of late-type stars to remnants of supernovae and up to the light emission from neutron star mergers, to name just a few. Despite their signifi- cance, however, little is known quantitatively about these processes for low- and medium-impact energies of, say, Ekin . 5000 eV of the free...
-
Ozone nanobubble technology as a novel AOPs for pollutants degradation under high salinity conditions
PublicationConventional water treatment systems frequently exhibit diminished efficiency at high salinity - a significant issue especially for real industrial effluents - mostly due to the creation of intricate structures between pollutants and salts. One of the primary obstacles associated with high salinity conditions is the generation of by-products that pose additional hurdles for treatment. In this work, we have investigated the novel...
-
Flow Maps and Flow Patterns of R1233zd(E) in a Circular Minichannel at Low, Medium and High Values of Saturation Pressure
PublicationThere is a gap in knowledge regarding the flow pattern of low-boiling working fluids in the range of high saturation temperatures (above 120°C) and medium and high reduced pressures (0.5-0.9). Data are present in the literature for similar values of reduced pressures, but for lower values of saturation temperature. This is due to the existing refrigeration applications of these working fluids. At high values of reduced pressure,...
-
Optimization of Hydrogen - Evolving Photochemical Molecular Devices
PublicationA molecular photocatalyst consisting of a RuII photocenter, a tetrapyridophenazine bridging ligand, and a PtX2 (X=Cl or I) moiety as the catalytic center functions as a stable system for light-driven hydrogen production. The catalytic activity of this photochemical molecular device (PMD) is significantly enhanced by exchanging the terminal chlorides at the Pt center for iodide ligands. Ultrafast transient absorption spectroscopy...
-
Inhibitors of angiogenesis in cancer therapy – synthesis and biological activity
PublicationAngiogenesis is the process of formation of new capillaries from preexisting blood vessels. Angiogenesis is involved in normal physiological processes, and plays an important role in tumor invasion and development of metastases. Vascular endothelial growth factor (VEGF) plays a key role in angiogenesis. VEGF is a mitogen for vascular endothelial cells and stimulates their proliferation. By inhibiting the biological activity of...
-
Hybrid P3HT: PCBM/GaN nanowire/Si cascade heterojunction for photovoltaic application
PublicationPoly(3-hexylthiophene) (P3HT) and phenyl-C61-butyric acid methyl ester (PCBM) are commonly used for the fabrication of organic photovoltaics (OPV). Efficiency limitations of OPVs could be circumvented by incorporation of inorganic nanostructures into organic blends. Again, integration of organic solar cells with well-developed silicon photovoltaic technology is ultimately desirable. In present work, GaN nanowires with diameters...
-
BODIPY‐Perylene Charge Transfer Compounds; Sensitizers for Triplet‐Triplet Annihilation Up‐conversion
PublicationBODIPY heterochromophores, asymmetrically substituted with perylene and/or iodine at the 2 and 6 positions were prepared and investigated as sensitizers for triplet-triplet annihilation up conversion (TTA-UC). Single-crystal X-ray crystallographic analyses show that the torsion angle between BODIPY and perylene units lie between 73.54 and 74.51, though they are not orthogonal. Both compounds show intense, charge transfer absorption...
-
Plasmon resonance in gold-silver nanoalloys
Open Research DataSurface plasmon resonance (SPR) can lead to improve or formation a new linear or nonlinear optical phenomena. Especially it can enhance a light emission from luminescence materials. The presence of metal nanostructures or nanoparticles is necessary to excitation of the SPR. It is well known that gold and silver nanostructures exhibit plasmon resonance...
-
Expert System and Decision Support System for Electrocardiogram Interpretation and Diagnosis: Review, Challenges and Research Directions
PublicationElectrocardiography (ECG) is one of the most widely used recordings in clinical medicine. ECG deals with the recording of electrical activity that is generated by the heart through the surface of the body. The electrical activity generated by the heart is measured using electrodes that are attached to the body surface. The use of ECG in the diagnosis and management of cardiovascular disease (CVD) has been in existence for over...
-
Curing epoxy with ethylenediaminetetraacetic acid (EDTA) surface-functionalized Co Fe3-O4 magnetic nanoparticles
PublicationIn this work, the bulk and surface composition of Fe3O4 supermagnetic nanoparticles were modified for efficient epoxy curing. The bare, ethylenediaminetetraacetic acid (EDTA) capped, and cobalt (Co)-doped EDTA capped Fe3O4 nanoparticles were synthesized electrochemically. The crystalline structure and phase information, surface capping, morphology and magnetization behavior of nanoparticles were studied by X-Ray diffraction (XRD),...
-
CERVIX UTERI, Exocervix - Female, 34 - Cell image [4200730008411221]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The Processing Procedure for the Interpretation of Microseismic Signal Acquired from a Surface Array During Hydraulic Fracturing in Pomerania Region in Poland
PublicationHydraulic fracturing is a procedure of injecting high pressure fluid into the wellbore in order to break shell rock and facilitate gas flow. It is a very costly procedure and, if not conducted properly, it may lead to environmental pollution. To avoid costs associated with pumping fluid outside the perspective (gas rich) zone and improve one’s knowledge about the reservoir rock, microseismic monitoring can be applied. The method...
-
Effects of Noncontact Shoulder Tool Velocities on Friction Stir Joining of Polyamide 6 (PA6)
PublicationIn this study, the effects of the traverse and rotational velocities of the noncontact shoulder tool on the heat generation and heated flux during the friction stir joining of high-density polyamide 6 (PA6) polymer were investigated. The computational fluid dynamics (CFD) method was employed to simulate the thermomechanical phenomena during the friction stir joining (FSJ) process of PA6. A developed model was used to consider the...
-
Low energy elastic scattering of electrons from hexafluoropropene (C3F6)
PublicationWe present cross sections from a joint experimental and theoretical study on elastic electron scattering from hexafluoropropene (C3F6) in the gas phase. The experimental results, using low energy electron spectroscopy, were obtained at incident electron energies of 0.5, 1, 1.5, 2, 3, 4, 5, 6, 10, 12, 15 and 20 eV, for scattering angles ranging from 10°to 130°. The theoretical method used in the computation of the integral, momentum...
-
Analysing the potential for application of the phase shift method in endoscopic examination of marine engines
PublicationThe article presents theoretical principles of image processing in digital endoscopy which makes use of a miniaturised spectral scanner “PhaseProbe” designed by General Inspection Technologies LP, the producer of the measuring videoendoscope Everest XLG3. The technology of optoelectronic 3D mapping of the examined surface, which consists in measuring the phase shift between the emitted and reflected light waves, is briefly described....
-
Surfactants application in sample preparation techniques: Insights, trends, and perspectives
PublicationSince the implementation of Green Chemistry into analytical practice, significant efforts have been made to improve the sustainability of chemical analysis. These include reducing the use of hazardous chemicals and solvents, minimizing waste, and improving energy efficiency. Surfactants can be applied in chemical analysis as an environmentally friendly alternative to conventional solvents and chemicals. The use of surfactants can...
-
Non-adiabatic Effects in Pressure Drop Calculations in Flow Boiling and Flow Condensation in Minichannels
PublicationConsiderations presented in the paper relate both to the case of flow boiling and flow condensation in conventional channels as well as small diameter ones. Authors devoted all the possible attention that the modeling presented is applicable to the whole range of quality variation in both cases of condensation and boiling. The form of two-phase flow multiplier, which is a major factor in modeling presented here, should be capable...
-
High-quality Experiment Dedicated to microGravity Exploration, Heat Flow and Oscillation Measurement from Gdańsk
PublicationIn this paper we propose HEDGEHOG (High-quality Experiment Dedicated to microGravity Exploration, Heat flow and Oscillation measurement from Gdańsk) REXUS experiment to investigate vibrational and heat flow phenomena during the whole (ascent, microgravity phase, descent and recovery) flight of a sounding rocket. First, a proposed system of cantilever beams is discussed to study dynamic behaviour of dummy payload. Dimensioning has...
-
Experimental and theoretical studies on the Sulfamethazine-Urea and Sulfamethizole-Urea solid-liquid equilibria
PublicationThe miscibility of active pharmaceutical ingredients with excipients is an important aspect in pharmaceutical technology protocols. In this study, the differential scanning calorimetry (DSC) was used for Sulfamethazine-Urea (SI–U) and Sulfamethizole-Urea (SO–U) solid-liquid phase diagrams determination. Both sulfonamides form simple binary eutectics with Urea. The lack of new co-crystal phase formation was confirmed by inspection...
-
Calculation method for flow boiling and flow condensation of R134a and R1234yf in conventional and small diameter channels
PublicationThe paper presents the results of calculations performed using the authors’ model to predict the heat transfer coefficient during flow boiling for two refrigerants R134a and R1234yf. The experimental data from various past studies have been collected and the calculations have been conducted for the full range of quality variation and a wide range of mass velocity. The aim of the study was to test the sensitivity of the in-house...
-
Cattaneo–Christov heat flow model for copper–water nanofluid heat transfer under Marangoni convection and slip conditions
PublicationThis report is devoted to the study of the flow of MHD nanofluids through a vertical porous plate with a temperature-dependent surface tension using the Cattaneo–Christov heat flow model. The energy equation was formulated using the Cattaneo–Christov heat flux model instead of Fourier’s law of heat conduction. The Tiwari–Das model was used to take into account the concentration of nanoparticles when constructing the momentum equation....
-
Characterization of glucoamylase immobilized on magnetic nanoparticles
PublicationMagnetic support was prepared by precipitation from an alkaline solution of divalent and trivalent iron ions and subsequently was modified with 3-aminopropyltriethoxysilane. FTIR analysis showed existence of a new Si-O-Fe bond in obtained particles. Scanning electronic microscopy images shows that the nanoparticles of all samples have particle size below 30 nm. Glucoamylase AMG 300L was immobilized onto the modified magnetic support...