Search results for: AIR SOURCE HEAT PUMP
-
Enhancement of the Brayton cycle efficiency by water or steam utilization
PublicationIn the paper, thermodynamic analysis of two modifications of a Brayton cycle into enhancement cycles with water/steam injection are discussed. The first one deals with a STIG modified system with both interstage compressed air cooling and air heating (heat regeneration) before combustion chamber. The second one, mainly devoted to higher steam/air ratio, is connected with separate steam production in a HRSG. The analysis has been...
-
Application of a catalytic combustion sensor (Pellistor) for the monitoring of the explosiveness of a hydrogen-air mixture in the upper explosive limit range
PublicationA new technique is presented for continuous measurements of hydrogen contamination by air in the upper explosive limit range. It is based on the application of a catalytic combustion sensor placed in a cell through which the tested sample passes. The air content is the function of the quantity of formed heat during catalytic combustion of hydrogen inside the sensor. There is the possibility of using the method in industrial installations...
-
An energetic analysis of a gas turbine with regenerative heating using turbine extraction at intermediate pressure - Brayton cycle advanced according to Szewalski's idea
PublicationIn this paper, a modification of a simple gas turbine into the Brayton cycle with regenerative heating, using turbine extraction at intermediate pressure, is presented. The main concept of the retrofitting is based on the transfer of heat from the turbine exhaust gases to the air entering the combustion chamber. The extracted gas transfers heat to air via the divided regenerative heat exchanger and after that is compressed and...
-
Adapting the pinch point analysis to improve the ORC design process
PublicationPinch point analysis can be adapted so as to assist in the early stages of designing the ORC systems. Typically used in determining the working parameters of heat exchangers, it can be employed to improve the heat fitting between the source of heat and the working fluids of the ORC system. To attain the parametric match, an algorithm was built enabling quick estimation of the possible heat reception by the specific working fluid....
-
Thermal-Hydraulic Studies on the Shell-and-Tube Heat Exchanger with Minijets
PublicationIn this paper a patented design of a heat exchanger with minijets, with a cylindrical construction is presented. It is followed by the results of its systematic experimental investigations in the single-phase convection heat transfer mode. Based on these results, validation of selected correlations (coming from the literature) describing the Nusselt number was carried out. An assessment of the heat exchange intensification level...
-
Empirical Relationship Describing Total Convective and Radiative Heat Loss in Buildings
PublicationOn the basis of theoretical considerations of convective-radiative heat transfer, a relationship was developed enabling the total convective and radiative heat flux QC+R emitted from any object at tw and its surroundings at t∞ to be calculated from known values of the surface temperature of such an object, i.e., the known temperature difference Δt=tw - t∞ and average air temperature Tav. This relationship is applied to thermal...
-
The topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope
Open Research DataThe topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope.
-
Experimental investigation on straight and u-bend double tube heat exchanger with active and passive enhancement methods
PublicationAuthors in this work want to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. In the study, Wilson plot approach was applied in order to estimate heat transfer coefficients for all heat exchanger (HX) configurations. The study focuses on experimental values of heat transfer coefficient...
-
Determination of benzo(a)pyrene content in PM10 using regression methods
PublicationThe paper presents an attempt of application of multidimensional linear regression to estimation of an empirical model describing the factors influencing on B(a)P content in suspended dust PM10 in Olsztyn and Elbląg city regions between 2010 and 2013. During this period annual average concentration of B(a)P in PM10 exceeded the admissible level 1.5-3 times. Conducted investigations confirm that the reasons of B(a)P concentration...
-
Cargo ships heat demand - operational experiment
PublicationThe paper presents the results of an experiment conducted on two cargo ships – a 5300 TEU container with a steam heating system and a 7500 dwt general cargo ship with a thermal oil system. On both ships research has been carried out using specially designed measuring equipment. After gathering data about flow velocity and temperatures (steam/ cooling water/ thermal oil/ seawater/ outside air), calculations have been done, resulting...
-
The topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with confocal microscope
Open Research DataThe topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with confocal microscope.
-
The topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with AFM
Open Research DataThe topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with AFM.
-
Photovoltaic module temperature stabilization with the use of phase change materials
PublicationThe worldwide growth of photovoltaics (PVs) has formed an exponential curve for more than four decades. During this period of time, PVs have evolved from a pure niche market of small-scale applications towards becoming a mainstream electricity source. The influence of temperature on the electrical parameters of crystalline silicon solar cells and solar modules is well described in the literature. In order to diminish these effects,...
-
Natural convection in symmetrically heated vertical channels
PublicationThe study describes natural convection through a vertical channel, open on four sides and bound by two isothermal walls. Both balancing and infrared experimental investigations were performed in air (Pr = 0.71) to estimate the impact of channel width s and wall-to-ambient temperature difference (tw - t∞) on natural convective heat transfer, the formation of air flow patterns and the rate of flow pattern formation. The study was...
-
The structure of vanadate glass-ceramics containing BaTiO3 measured with X-ray diffraction method
Open Research DataThe structure of vanadate glass-ceramics doped with BaTiO3 was measured by XRD. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated...
-
The morphology of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with AFM
Open Research DataThe morphology of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses was measured with the use of atomic force microscope.
-
SZACOWANIE ZAWARTOŚCI BENZO(a)PIRENU W PYLE ZAWIESZONYM PM10 W AGLOMERACJI TRÓJMIEJSKIEJ ZA POMOCĄ WIELOWYMIAROWEJ REGRESJI LINIOWEJ=ESTIMATION OF BENZO(A)PYRENE CONTENT IN SUSPENDED DUST PM10 IN TRI-CITY AGGLOMERATION USING MULTIDIMENSIONAL LINEAR REGRESSION
PublicationW pracy przedstawiono próbę oszacowania przy pomocy wielowymiarowej regresji liniowej modelu empirycznego opisującego czynniki wpływające na zawartość B(a)P w pyle zawieszonym PM10 w Aglomeracji Trójmiejskiej w latach 2008-2011. Na przestrzeni tych lat średnioroczne stężenie B(a)P w PM10 wzrosło ponad dwukrotnie i ponad trzykrotnie przewyższa poziom docelowy. Z przeprowadzonych analiz wynika, że główną przyczyną wzrostu stężenia...
-
Charakterystyka eksploatacyjna pomp ciepła zainstalowanych w oczyszczalni ścieków
PublicationW artykule przedstawiono charakterystykę eksploatacyjną sprężarkowych pomp ciepła zainstalowanych w oczyszczalni komunalnej i wykorzystujących ścieki oczyszczone jako dolne źródło ciepła. Zastosowanie ścieków oczyszczonych jest uzasadnione ich dostępnością oraz stosunkowo wysoką temperaturą (10-25°C). Prawidłowa eksploatacja układu wymaga zastosowania pośredniego obiegu parowacza oraz regularnych zabiegów czyszczenia wymiennika...
-
ENERGY STORAGE IN COMPRESSED AIR – SOLUTION SUPPORTING RENEWABLE ENERGY SOURCES
PublicationThis article presents a brief description of a power system, the current national power system daily load, the use of wind power as a renewable energy source and its share in the national load. It also discusses the methods for storing energy, their characteristics and possible solutions. The power storage and generation solution proposed in the article is based on the collaboration between a gas turbine and an air storage system....
-
Performance analyses of helical coil heat exchangers. The effect of external coil surface modification on heat exchanger effectiveness
PublicationThe shell and coil heat exchangers are commonly used in heating, ventilation, nuclear industry, process plant, heat recovery and air conditioning systems. This type of recuperators benefits from simple construction, the low value of pressure drops and high heat transfer. In helical coil,centrifugal force is acting on the moving fluid due to the curvature of thetube results in the development. It has been long recognized that the...
-
Increase of power and efficiency of the 900 MW supercritical power plant through incorporation of the ORC
PublicationThe objective of the paper is to analyse thermodynamical and operational parameters of the supercritical power plant with reference conditions as well as following the introduction of the hybrid system incorporating ORC. In ORC the upper heat source is a stream of hot water from the system of heat recovery having temperature of 90 °C, which is additionally aided by heat from the bleeds of the steam turbine. Thermodynamical analysis...
-
Combined operation of 900MW power plant with the ORC through the bleed steam extraction point and CO2 recovery system
PublicationThe work presented here is aimed at utylisation of waste heat in the reference supercritical power plant in the manner to produce electricity in ORC installation. The waste heat is available in the form of a stream of hot water at 90 C, recovered from the exhaust gases in the amount of 200MW. Such low enthalpy heat source is rather insufficient to produce a good quality vapour to feed the ORC turbine. Therefore an original approach...
-
Combined cold supply system for ship application based on low GWP refrigerants - Thermo-economic and ecological analyses
PublicationThe withdrawal of popular high-GWP refrigerants will significantly affect maritime industry. Refrigeration and air conditioning systems currently used on ships are not ready to fulfil future limitations. Therefore, there is a need for system, which will operate with low-GWP refrigerants and at the same time will be efficient and reliable in difficult environmental conditions. This paper explains the concept of a cold supply system,...
-
Experimental research on helical coil biomass boiler with oil as a heating fluid
PublicationThis paper presents an experimental research of helical coil biomass boiler with thermal oil heating agent. Heat exchanger consists of two coaxial helical coils swept by the flue gases. The burner is a single vertical retort connected to the fuel tank (wooden pellets). The boiler is a part of micro-power plant in which the heat from the boiler is exchanged with low-boiling HFE7100 to produce steam for a custom steam turbine. The...
-
Photovoltaic Roof Tiles: The Influence of Heat Recovery on Overall Performance
PublicationA photovoltaic (PV) roof tile serves both as a roofing material and as an electricity-producing surface. The main aim of the present study was to increase the overall system efficiency of PV tiles by using heat recovery. The chosen strategy was two-fold: determine the operational efficiency of PV tiles and optimize construction to increase the cooling effect when using air as the working medium. A detailed experimental study was...
-
The effect of laser on metal surfaces for multidisciplinary usage in material and thermal engineering
PublicationThe subject of heat transfer and cooling systems is still a matter of contention in many different fields of science and industry. Infrigidation is much more difficult than warming, and so, much more needed in more and more different devices, starting from massive industrial machinery and air conditioning in commercial buildings, up to micro and nano-surgery tools. In fact, the size of many cooling systems is still a problem. It...
-
Operation of the 900 MW power plant with the ORC supplied from three heat sources
PublicationThe chapter is aimed at utilisation of waste heat in the reference supercritical power plant in the manner to produce electricity in ORC installation. The waste heat is available in the form of a stream of hot water at 90°C, recovered from the exhaust gases in the amount of 200MW. Such low enthalpy heat source is rather insufficient to produce a good quality vapour to feed the ORC turbine. Therefore an original approach to increase...
-
Cooperation of ORC installation with a gas boiler as a perspective co-generation system for households
PublicationThis paper reports tests of an innovative micro-CHP unit prototype, consisting of a traditional gas boiler and organic Rankine cycle (ORC), which incorporates original system components such as an axial vapour microturbine, evaporator and condenser. The system co-generates heat and electricity for a single household or a group of households. Electricity is only a by-product during production of heat. While testing the prototype,...
-
Alternative cogeneration thermodynamic cycles for domestic ORC
PublicationThe Organic Flash Cycle (OFC) is suggested as a vapor power cycle that could potentially improve the efficiency of utilization of the heat source. Low and medium temperature finite thermal sources are considered in the cycle. Additionally the OFC’s aim is to reduce temperature difference during heat addition. The study examines 2 different fluids. Comparisons are drawn between the OFC and an optimized basic Organic Rankine Cycle...
-
Numerical analysis of high temperature minichannel heat exchanger for recuperative microturbine system
PublicationConsidering the development of energy sector, distributed small-scale power generation, e.g., gas micro-CHP, is attracting considerable interest. In such installations, the heat exchanger is one of the key components possessing a significant influence on overall performance. Most studies concentrate on units operating below 900C, which do not fulfil the requirements of gas micro-CHP. Therefore, there remains a challenge to design...
-
Effect of the inclination angle of the condenser on the heat transfer coefficient value – experimental study
PublicationWhen considering problem of the condensation of the refrigerant in a flow inside channel, one needs to pay attention to the shape of its cross-section, the hydraulic diameter, the channel length as well as the orientation of the channel axis in space (horizontal, vertical, inclined). This paper presents an experimental study concerning the effect of the inclination angle of the condenser with a single coil pipe on the heat transfer...
-
HIGH TEMPERATURE HEAT PUMPS – PERSPECTIVE HEATING SYSTEMS?
PublicationIn the paper presented are authors own concepts of high temperature compressor heat pumps for the utilisation of medium and low temperature sources of heat. Working fluids for use in high temperature heat pumps are discussed, as well as the criteria for their selection. Analyses are presented for the production of in the upper steam source at 130 °C. One-stage systems and cascade systems were analyzed. An analysis of the coefficient...
-
Domestic ORC micro-CHP combined with a commercial gas boiler
PublicationThe chapter presents the results of experimental studies conducted during the launch of the first in Poland demonstration prototype of the micro ORC coupled to a domestic gas boiler. The accomplished studies indicated the possibility for the ORC module to work with such boiler (autonomous source of heat) with a prototype single-stage axial micro turbine as the expansion machine. Confirmation of that fact has been delineated in...
-
Active management of equipment cooling in hoteling data centers
PublicationHoteling data centers are designated for housing computing and storage units of many, usually small customers, as opposed to traditional data centers supporting own computing and storage resources of a bigger company. One of the services to be provided to consumer’s equipment is cooling. Cooling in data centers is prevalently achieved by circulating air in computer room. Efficient cooling requires delivering cold air from central...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublicationCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Investigations of Energy Conversion and Surface Effect for Laser-Illuminated Gold Nanorod Platforms
PublicationAchieving a quick temperature increase is a burning issue for biophysical applications, like germ inactivation and tumor ablation, and for energy performances, like solar collectors and steam generators. Based on the plasmon resonance phenomenon, noble metallic nanoparticles have emerged as promising weapons due to their very high biocompatibility, optical properties, and high surface-to-volume ratio, increasing energy conversion...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...