Filters
total: 1710
displaying 1000 best results Help
Search results for: ELECTROSPRAY MASS SPECTROMETRY
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Five years of innovations in development of glow discharges generated in contact with liquids for spectrochemical elemental analysis by optical emission spectrometry
Publication -
Least Squares Estimators of Peptide Species Concentrations Based on Gaussian Mixture Decompositions of Protein Mass Spectra
Publication -
Towards a global historical emission inventory for selected PCB congeners - a mass balance approach. 3. An update
PublicationPoprzednie prace autorów zawierały bardzo istotne informacje do oceny stężeń związków polychlorobifenylowych (PCB) w rejonach oddalonych od dużych źródeł emisji tych związków jak i w środowisku globalnym. Okazało się, że niezbędna jest modyfikacja emisji PCB po roku 2000. Przedstawiono nowe dane o produkcji PCB w Polsce oraz nowe dane nt. składu chemicznego różnych produktów technicznych opartych na PCB. Ulepszono też metody oceny...
-
The Effect of the Body Mass Indexes of Young Healthy Individuals on the Glyacemic Indexes of Traditional and Modified Vegetarian Meals
Publication -
Recycling of Plastic Wastes for the Mass Production of Yolk–Shell-Nanostructured Co3O4@C for Lithium-Ion Batteries
Publication -
One-pot green mass production of hierarchically porous carbon via a recyclable salt-templating strategy
Publication -
Interconnected nanoporous carbon structure delivering enhanced mass transport and conductivity toward exceptional performance in supercapacitor
Publication -
Friction Tuned Mass Dampers in Seismic-Excited High-Rise Buildings with SSI Effects: A Reliability Assessment
Publication -
INDICES OF VASCULAR STIFFNESS AND WAVE REFLECTION IN RELATION TO BODY MASS INDEX OR BODY FAT IN HEALTHY SUBJECTS
Publication -
Recycling of Plastic Wastes for the Mass Production of Yolk–Shell-Nanostructured Co3O4@C for Lithium-Ion Batteries
Publication -
Towards Designing an Innovative Industrial Fan: Developing Regression and Neural Models Based on Remote Mass Measurements
PublicationThis article presents the process of the construction and testing a remote, fully autonomous system for measuring the operational parameters of fans. The measurement results obtained made it possible to create and verify mathematical models using linear regression and neural networks. The process was implemented as part of the first stage of an innovative project. The article presents detailed steps of constructing a system to...
-
Collaboration between a proportional-derivative and a model-based controllers in case of a variable mass redundantly articulated manipulators
PublicationW pracy zaprezentowano wyniki analizy numerycznej dynamiki złożonego układu mechatroniczego. Częścią mechaniczną analizowanego układu jest manipulator sterowany nadmiarowo. Rozważania ograniczono do analizy płaskiego manipulatora równoległego. Część sterująca to układ sterowania (regulacji) z modelem. Analizowane zadanie polega na wymuszeniu ruchu wzdłuż zadanej trajektorii. Problemy związane ze sterowaniem prowadzą nas do pierwszego...
-
Modeling and control of a redundantly actuated variable mass 3RRR planar manipulator controlled by a model-based feedforward and a model-based-proportional-derivative feedforward–feedback controller
PublicationIn the paper, dynamics of a complex mechatronics system is considered. A redundantly actuated planar manipulator is the base of the mechanical part of it. It is a 3RRR 1 platform based parallel manipulator. To control its trajectory, a model-based feedforward controller is employed. Three aspects are fundamental in the presented investigations. The first focus is on development of an accurate numerical model used to solve the inverse...
-
Recent Applications of 1D GC-MS and 2D GC-MS in Foodomics Studies
PublicationGas chromatography coupled with mass spectrometry and food chemistry have been tightly linked since the 1960s. This setup is also an integral part of the omics studies when it comes to low mass metabolites. Therefore, the marriage of GC-MS and foodomics is obvious. Two-dimensional gas chromatography coupled with mass spectrometry fits perfectly within the latest trends in foodomics, since it is tailored for holistic food analysis....
-
INNOVATIVE THERMODYNAMICAL CYCLES BASED ON ENHANCEMENT MASS, MOMENTUM, ENTROPY AND ELECTRICITY TRANSPORT DUE TO SLIP, MOBILITY, TRANSPIRATION, ENTROPY AND ELECTRIC JUMPS AS WELL AS OTHER NANO-FLOWS PHENOMENA
PublicationIn our work, a further development of the authors model of thermo-chemical flow of fuel, air, oxygen, steam water, species, ionic and electron currents within nano channels and nano-structures of novel devices is presented. Different transport enhancement models are taken into account -among them the most important are: the velocity slip connected with complex external friction, the Darcy mobility and the Reynolds transpiration....
-
Solid phase extraction and sequential elution for pre-concentration of traces of Mn and Zn in analysis of honey by flame atomic absorption spectrometry
Publication -
Molecularly imprinted stir bar sorptive extraction coupled with atomic absorption spectrometry for trace analysis of copper in drinking water samples
Publication -
Dariusz Mikielewicz prof. dr hab. inż.
PeopleProfessor Dariusz Mikielewicz – born on February 6, 1967. in Gdansk. Here in 1974 he enrolled first to the Elementary School No. 17, and then in the Grammar School No. 5, named after Stefan Żeromski in Gdansk-Oliwa. After graduating from the Secondary School, with honors, in 1985 he successfully passed the entrance exams to the Faculty of Mechanical Engineering of Technical University of Gdansk, where he graduated with a very good...
-
Absence of 6-Hydroxydopamine in the Rat Brain After Treatment with Stimulants and Other Dopaminergic Agents: A Mass Fragmentographic Study
Publication -
Determination of twenty pharmaceutical contaminants in soil using ultrasound-assisted extraction with gas chromatography-mass spectrometric detection
Publication -
Investigation of the flow, heat and mass transfer and emissions in pulverized fuel fired boiler using physical and numerical modeling.
PublicationPraca przedstawia wykorzystanie techniki modelowania fizycznego trójwymiarowego oraz obliczeń numerycznych umożliwiających symulację rzeczywistych procesów spalania paliw stałych i gazowych w urządzeniach energetycznych. Dodatkowo wyniki obliczeń porównano z wynikami modelowania fizycznego oraz pomiarów na obiekcie rzeczywistym.
-
Mass transfer in the bath reactor of the adsorption process of 1,2-dichloropropane from aqueous solution onto the activated carbon
Publication -
IEEE Conference on Mass Storage Systems and Technologies
Conferences -
Solid phase extraction with flame atomic absorption spectrometry for determination of traces of Ca, K, Mg and Na in quality control of white sugar
Publication -
Sensitive Determination of Cd in Small-Volume Samples by Miniaturized Liquid Drop Anode Atmospheric Pressure Glow Discharge Optical Emission Spectrometry
Publication -
Development of direct-current, atmospheric-pressure, glow discharges generated in contact with flowing electrolyte solutions for elemental analysis by optical emission spectrometry
Publication -
Hanging drop cathode-atmospheric pressure glow discharge as a new method of sample introduction for inductively coupled plasma-optical emission spectrometry
Publication -
Determination of methylcyclopentadienyl-manganese tricarbonyl in gasoline and water via ionic-liquid headspace single drop microextraction and electrothermal atomic absorption spectrometry
Publication -
Monitoring of volatile organic compounds (VOCs) in atmospheric air. Part I. On-line gas analyzers
PublicationThe paper reviews the subject literature concerning the analytical instruments routinely used for monitoring volatile organic compounds in atmospheric air. The analyzers are classified as stationary or mobile according to their ease of transport. Stationary DOAS (Differential Optical Absorption Spectroscopy) analyzer is characterized, as are MIMS (Membrane Introduction Mass Spectrometry), MESI (Membrane Extraction with Sorbent...
-
High-resolution synthesis of high-density breast mammograms: Application to improved fairness in deep learning based mass detection
Publication -
Characterization of the interactions between human high-molecular-mass kininogen and cell wall proteins of pathogenic yeasts, Candida tropicalis
Publication -
Characteristics of Cucumis metuliferus, Actinidia deliciosa and Musa paradisica fragrance profiles using a comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection (GC×GC-TOF MS)
PublicationComprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection (GC×GC-TOF-MS) is a modern analytical technique used in many fields. This technique enables an effective separation of volatile chemical compounds [1]. In recent years, the topic of healthy food and healthy living has become very popular. For this reason, more and more scientific publications related to the analysis of food products...
-
Funcionality assessment of Citrus Hysteria peel as a protective barrier using gas chromatography
PublicationThe aim of this study was to analyse the volatile fractions of fruit peel and pulp using two-dimensional gas chromatography technique coupled with mass spectrometry. The isolation of the compounds was achieved by microextraction to the stationary phase from the headspace of the sample (HS-SPME). Mass spectrometry with time-of-flight analyser (TOF-MS) was used to identify the chemical compounds. There are no reports in the literature...
-
On the coupling of hydride generation with atmospheric pressure glow discharge in contact with the flowing liquid cathode for the determination of arsenic, antimony and selenium with optical emission spectrometry
Publication -
Evaluation of the potential of Microwave Plasma–Atomic Emission Spectrometry for trace elements leaching assessment from the concrete matrix with sewage sludge ash additives
PublicationThe management of ash generated during the thermal utilization of sewage sludge is a significant environmental problem requiring an effective technological solution. One alternative way to dispose of sewage sludge is to bind it in concrete as a substitute for part of the aggregate. The properties of the C-S-H phase enable effective immobilization of harmful substances that sewage sludge contains. The amount of individual compounds...