Filters
total: 4760
-
Catalog
- Publications 3615 available results
- Journals 33 available results
- Conferences 14 available results
- People 43 available results
- Projects 6 available results
- Research Teams 1 available results
- Research Equipment 1 available results
- e-Learning Courses 10 available results
- Events 2 available results
- Open Research Data 1035 available results
displaying 1000 best results Help
Search results for: LOW VOLTAGE GRID
-
Low cost microwave X-band generator
PublicationA low cost microwave X-band generator for educational purposes was designed and built. Its simple construction and user's interface makes it suitable for a student laboratory.The generator is based on a single frequency conversion concept. It uses a digitally tunable PLL chip for intermediate frequency generation and an active frequency multiplier for frequency conversion. The generator covers 9,7 - 11 GHz part of the X frequency...
-
ANN for human pose estimation in low resolution depth images
PublicationThe paper presents an approach to localize human body joints in 3D coordinates based on a single low resolution depth image. First a framework to generate a database of 80k realistic depth images from a 3D body model is described. Then data preprocessing and normalization procedure, and DNN and MLP artificial neural networks architectures and training are presented. The robustness against camera distance and image noise is analysed....
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031839801]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835991]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031832721]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031837111]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031832401]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [612073003183971]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031834931]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835891]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835811]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [612073003183841]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031834521]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Enhanced method of DS-CDMA low level singnals detection
PublicationThe following article comprises three main parts. The first one generally describes two methods of low level signals detection which are in the interest of this study. The signal spectrum averaging technique is shown as well as the method exploiting averaged spectrum of the signal raised to the power of 2n (nN). Additionally, this section briefly presents proposed enhancements and modifications of these two solutions, which allow...
-
On the low-cost design of abbreviated multisection planar matching transformer
PublicationA numerically demanding wideband matching transformer composed of three nonuniform transmission lines (NUTLs) has been designed and optimized at a low computational cost. The computational feasibility of the design has been acquired through the exploitation of low-fidelity NUTL models in most steps of the design procedure and an implicit space mapping optimization engine, providing high accuracy results with only a handful of EM...
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Low-power device simulator for micro-energy measurement methods testing
PublicationThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Low grade serous carcinoma - Female, 45 - Tissue image [4100730020135251]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Low grade serous carcinoma - Female, 45 - Tissue image [4100730020137471]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Low-Reflection Subgridding
PublicationArtykuł przedstawia technikę umieszczania makromodeli w trójwymiarowej siatce dyskretyzacji metody różnic skończonych. Umożliwia ona łączenie obszarów siatki o różnym kroku dyskretyzacji. Zastosowana prosta interpolacja liniowa wraz z kolokacją pól sąsiadujących ze sobą podobszarów prowadzi do uzyskania małego współczynnika odbicia od obszaru z gęstą siatką.
-
Assessment of Tensile Strength Reserve of Asphalt Mixtures at Low Temperatures
PublicationDuring winter conditions, low-temperature cracks develop at the surface of the asphalt pavement when tensile thermal stress induced in the asphalt layer during cooling equals and exceeds the tensile strength of the material. The paper presents the results of tensile strength reserve assessment of asphalt mixtures with neat and SBS-polymer modified bitumen application. The tensile strength reservewas calculated as difference between...
-
Experimental test of nonclassicality with arbitrarily low detection efficiency
PublicationWe theoretically introduce and experimentally demonstrate the realization of a nonclassicality test that allows for arbitrarily low detection efficiency without invoking an extra assumption of independence of the devices. Our test and its implementation is set in a prepare-and-measure scenario with an upper limit on the classical communication capacity of the channel through which the systems are communicated. The essence for our...
-
Low-Cost Automated Design of Compact Branch-Line Couplers
PublicationBranch-line couplers (BLCs) are important components of wireless communication systems. Conventional BLCs are often characterized by large footprints which make miniaturization an important prerequisite for their application in modern devices. State-of-the-art approaches to design of compact BLCs are largely based on the use of high-permittivity substrates and multi-layer topologies. Alternative methods involve replacement of transmission-line...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.
-
Magneto-thermal convection of low concentration nanofluids
PublicationThe main aim of this paper was to analyze possible utilization of the low concentration nanofluids and the magnetic field to enhance heat transfer. The studied fluids were based on water with an addition of copper particles (40-60 nm diameter). They belonged to the diamagnetic group of materials. As a first attempt to stated target the analysis of enclosure placed in the maximal value of square magnetic induction gradient was carried...
-
Novel microstrip low-pass filters with fractal defected ground structures
PublicationIn this study, three microstrip low-pass filters (LPFs) containing fractal-shaped defected ground structures have been designed and manufactured. To improve the performance of microstrip LPF, cascades of inductively coupled fractal resonators have been applied. Simultaneously, to achieve relatively constant microstrip impedance resulting in essentially low reflection losses, a modification of the strip geometry has been introduced....
-
Polarisation effects in low-energy positron–molecule scattering
PublicationThe UK molecular R-matrix method has been adapted to treat positron collisions from polyatomic targets. A simple empirical enhancement factor which corrects for the underestimation of electron–positron polarisation and correlation effects in the calculations performed with the static-plus-polarization model at low scattering energies is presented. Application of this model to positron scattering from carbon dioxide at energies...
-
Low energy differential elastic electron scattering from trichloromethane
PublicationExperimental differential cross sections for low energy electron scattering from trichloromethane is measured utilizing a crossed electron-molecular beam experiment via the relative flow method, for the incident electron energies in the range of E = 0.5 eV-30 eV and the scattering angles in the range of θ = 10◦ − 130◦ .
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012691141]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012696861]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [3300730069462421]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012698861]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012697521]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012699801]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012693811]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012697411]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012693381]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Ultra Low Noise Poroelastic Road Surfaces
PublicationNoise is one of the most important environmental problems related to road traffic. During the last decades, the noise emitted by the engines and powertrains of vehicles was greatly reduced and tires became a clearly dominant noise source. The article describes the concept of low noise poroelastic road surfaces that are composed of mineral and rubber aggregate bound by polyurethane resin. Those surfaces have a porous structure and...
-
The AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters
Open Research DataThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
Jumping Wave Characteristic during Low Plasticity Burnishing Process
PublicationDuring the low plasticity burnishing process of soft materials such as carbon steel with a hardness of up to 40 HRC (Rockwell grade) a raised structure of the material known as the Jumping Wave forms in front of the tool roll. This phenomenon significantly disturbs the burnishing process, but is very poorly described in the literature. This article presents studies of this phenomenon on the example of burnished 1.0562 steel. The...
-
Low-Temperature Requirements for Bitumen in Central East European Road Construction
PublicationThe paper presents the proposition of special assessment of lowtemperature requirements for bitumens in the region of Central and Eastern Europe where there is a moderate transitional area from sea to the continental type of climate. The results of the research program conducted on the road neat bitumens, Styrene-Butadiene-Styrene polymer and polymer-rubber modified bitumen, and multigrade bitumen types were presented and discussed....
-
Low grade serous carcinoma - Female, 45 - Tissue image [4100730020134161]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Low grade serous carcinoma - Female, 45 - Tissue image [4100730020132541]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [3300730069454481]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [1101063008856651]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [3300730069451541]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [11010630088562941]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [11010630088568781]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.