Filters
total: 35
Search results for: EUROCODE
-
Application of the ‘CPT 2012’model of AFNOR standard for column design in Poland–Jazowa case study
Publicationhis paper presents the ‘CPT 2012’ model incorporated into the AFNOR NF P94-262:2012-07, French standard for pile design fully compatible with Eurocode 7, to the wider Polish audience. The bearing capacity of three reference columns for Vistula Marshlands have been calculated according to ‘CPT 2012’ model and AFNOR recommendations. Then, the design resistances have been compared with ultimate column bearing capacity measured during...
-
ANALYSIS OF BRACE STIFFNESS INFLUENCE ON STABILITY OF THE TRUSS
PublicationThe paper is devoted to the numerical and experimental research of stability of a truss with side elastic supports at the top chord. The structure is a model of a real roof truss scaled by factor ¼. The linear buckling analysis and non-linear static analysis were carried out. The buckling length factor for the compressed top chord was calculated and the limit load for the imperfect truss shell model with respect to brace stiffness...
-
Analysis of EN 1993-1-6 guidelines about determining amplitudes of equivalent imperfections of steel cylindrical shells subjected to uniform external pressure
PublicationCivil engineering structures should be designed with reference to relevant standards. One of them is a Eurocode 3 standard EN 1993-1-6:2007: Design of steel structures Part 1-6: Strength and Stability of Shell Structures. According to this standard, the value of buckling load can be determined using different approaches: classical hand calculations (stress design) and geometrical and material non-linear analysis of an imperfect...
-
PRELIMINARY FIELD TESTS AND LONG-TERM MONITORING AS A METHOD OF DESIGN RISK MITIGATION: A CASE STUDY OF GDAŃSK DEEPWATER CONTAINER TERMINAL
PublicationAppropriate risk assessment plays a fundamental role in the design. . The authors propose a possible method of design risk mitigation, which follows recommendations included in Eurocode 7. The so-called “Observational Method” (OM) can produce savings in costs and programmes on engineering projects without compromising safety. The case study presented is a complex design solution that deals with the heavy foundations of a gantry...
-
Stability and load bearing capacity of a braced truss under upward wind loading
PublicationThe paper is focused on the numerical and experimental investigation of stability of a steel truss under upward wind loading. The structure was stiffened by elastic braces situated at the top and bottom chord. Usually the lateral (translational) brace stiffness is considered. However, the rotational stiffness of braces caused by interaction between torsional stiffness of the truss top chord and bending stiffness of the roof elements...
-
Stability and load bearing capacity of a braced truss under upward wind loading
PublicationThe paper is focused on the numerical and experimental investigation of stability of a steel truss under upward wind loading. The structure was stiffened by elastic braces situated at the top and bottom chord. Usually the lateral (translational) brace stiffness is considered. However, the rotational stiffness of braces caused by interaction between torsional stiffness of the truss top chord and bending stiffness of the roof elements...
-
Investigation of stability and limit load of a truss overhead opened bridge
PublicationThe paper presents selected methods of determining stability and limit load of a truss top chord in opened bridges. These methods include linear buckling and non-linear static analysis based on the finite element method and algorithms based on design code procedures. The described methods were tested on an example of a steel footbridge situated in Straszyn. The results of stability analysis are compared. The results of geometrical...
-
Experimental Studies of Concrete-Filled Composite Tubes under Axial Short- and Long-Term Loads
PublicationThe paper presents experimental studies on axially compressed columns made of concrete-filled glass fiber reinforced polymer (GFRP) tubes. The infill concrete was C30/37 according to Eurocode 2. The investigated composite pipes were characterized by different angles of fiber winding in relation to the longitudinal axis of the element: 20, 55 and 85 degrees. Columns of two lengths, 0.4 m and 2.0 m, were studied. The internal diameter...
-
Concrete-filled FRP tubular members in marine and bridge structures
PublicationConcrete core of the concrete-filled tubes (CFTs) with circular cross-section is in the case of an axial compression subjected to a spatial state of compressive stresses. This state leads to enhancement in the concrete strength. The enhancement is utilized in Eurocode 4 design procedures for CFSTs (i.e. CFTs with tube made of steel). The structural design of CFFTs (i.e. CFTs with tube made of Fibre Reinforced Polymer - FRP) is...
-
Buckling resistance of a metal column in a corrugated sheet silo - experiments and non-linear stability calculations
PublicationThe results of experimental and numerical tests of a single corrugated sheet silo column’s buckling resistance are presented in this study. The experiments were performed in a real silo with and without bulk solid (wheat). A very positive impact of the bulk solid on the column buckling resistance occurred. The experimental results were first compared to the buckling resistance calculated by Eurocode 3 formulae. The comparison revealed that...
-
Porównanie obciążenia wiatrem wyznaczonego na podstawie procedur normowych z wynikami symulacji w cyfrowym tunelu aerodynamicznym dla hali stalowej.
PublicationW niniejszych badaniach porównano obciążenia od wiatru wyznaczonego metodą normową oraz w cyfrowym tunelu aerodynamicznym. Analizom poddano typowy budynek hali na planie prostokąta z dwuspadowym dachem w czterech wariantach geometrycznych. W pierwszym etapie budynki zwymiarowano bazując na obciążeniach od wiatru wyznaczonych według Eurokodu. Następnie dla poszczególnych elementów konstrukcyjnych określono poziom wytężenia. Dla...
-
INFLUENCE OF TIME ON THE BEARING CAPACITY OF PRECAST PILES
PublicationOne of the most popular types of foundations in layered subsoil with very differentiated soil shear strengths are precast piles. One of the reasons is a fact that we can well control the driving process during the installation of these piles. The principles of the assessment of bearing capacity and settlements of the piles given by Eurocode 7, concentrate on two main methods, i.e. Static Pile Load Tests (SPLT) and Dynamic Driving...
-
Experimental investigation of joint with positive eccentricity in CFS truss
PublicationDue to technological restrictions, in the case of trusses made of CFS open cross-sections, positive eccentricities in the truss joints have become very frequent. Therefore studies concerning the load-bearing capacity of truss joints with positive eccentricity were undertaken. It was assumed that the resistance of cold-formed steel (CFS) open cross-section truss joints located on compression chords and with positive eccentricity...
-
Influence of Actual Curing Conditions on Mechanical Properties of Concrete in Bridge Superstructures
PublicationThis article presents the research on the mechanical characteristics of concrete in the construction of three concrete bridges. A system of recording the internal temperature of concrete and automatic control of laboratory ovens was used for specimen curing. This allowed the specimens to be cured under conditions similar to those occurring in the structure. Before the construction, reference blocks were used to define similar curing...
-
Dariusz Kowalski dr inż.
People