Comparison of Evaluation of Air Odour Quality in Vicinity of Petroleum Plant Using a Prototype of Electronic Nose Instrument and Fast GC Technique
PublicationThe paper presents the results of investigation on classification of the ambient air samples collected in a vicinity of the LOTOS Group S.A. petroleum plant with respect to odour. The investigations were carried out with an electronic nose prototype and a commercial electronic nose of Fast GC-type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and a photoionization sensor of PID-type....
-
Comparison of Quality Evaluation of Agricultural Distillates Using Prototype of Electronic Nose and Fast/Flash GC
PublicationThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. In case of the prototype volatile fraction of the agricultural distillate was prepared via barbotage process. HERACLES II analysed the...
-
Thermographic images during testing measuring instrument boards
Open Research DataThe dataset presents thermografic images acquired during testing the prototype of measuring instrument for resistiometric corrosion monitoring. The testing was performed in the room temperature. VIGOcam v50 thermal imaging camera (VIGO System S.A., Ozarow Mazowiecki, Poland) was used for taking the pictures. These pictures were used as preliminary tests...
-
Application of an Electronic Nose Instrument to Fast Classification of Polish Honey Types
PublicationThe paper presents practical utilization of an electronic nose prototype, based on the FIGARO semiconductor sensors, in fast classification of Polish honey types—acacia flower, linden flower, rape, buckwheat and honeydew ones. A set of thermostating modules of the prototype provided gradient temperature characteristics of barbotage-prepared gas mixtures and stable measurement conditions. Three chemometric data analysis methods...
-
Monitoring of Odour Nuisance from Landfill Using Electronic Nose
PublicationThe paper presents the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type –HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. Classification of the air samples...
-
Quality evaluation of agricultural distillates using different types of electronic noses
PublicationThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with TGS type semiconductor sensors. HERACLES II included two chromatographic columns with different polarity of stationary phase and two FID detectors. In case of the prototype volatile fraction...
-
Comparison of different types of electronic nose instruments for evaluation of odour nuisance from landfill
PublicationThe paper presents and compares the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with six semiconductor sensors of TGS type. Classification of the air...
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublicationThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Discrimination of selected fungi species based on their odour profile using prototypes of electronic nose instruments
PublicationThe paper presents practical application of an electronic nose technique to fast and efficient discrimination of the samples of different fungi species such as: Penicillium chrysogenum, Cladosporium herbarum, Rhizopus oryzae, Alternaria alternata. Two prototypes of electronic nose instrument were utilized for investigation of discrimination capability with respect to odour profile of these fungi: the first prototype was based on...
-
Quality Evaluation of Agricultural Distillates Using an Electronic Nose
PublicationThe paper presents the application of an electronic nose instrument to fast evaluation of agricultural distillates differing in quality. The investigations were carried out using a prototype of electronic nose equipped with a set of six semiconductor sensors by FIGARO Co., an electronic circuit converting signal into digital form and a set of thermostats able to provide gradient temperature characteristics to a gas mixture. A volatile fraction...
-
Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks
PublicationThis paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills and sewage treatment plants were subjected...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublicationThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Use laser to measure girder deflection
PublicationThe paper presents a new, simple way to measure deflection of selected intens using the device dkkz-2010, which user a laser light source.