Search results for: SLAB–COLUMN CONNECTIONS
-
Analysis of floor-to-column pounding of buildings founded on different soil types
PublicationThe aim of this study is to investigate the effect of the soil type on buildings experiencing floor-to-column pounding during earthquakes. Five buildings with 4-storeys, 6-storeys, and 7-storeys were considered. Three types of the 4-storey building with different total heights were taken into account which leads to floor-to-column pounding at 1/3, 1/2 and 2/3 of the height of the impacted column. Two pounding scenarios were considered,...
-
Torque capacity of multidisc wet clutch with reference to friction occurrence on its spline connections
PublicationIn this article developed mathematical model that includes friction occurrence on spline connections is presented. The work also contains results of experimental research on torque capacity of multidisc wet clutch. These results are expressed as a function of contact pressure for different number of friction surfaces. Due to increased interest in research concerning multidisc wet clutches it is essential to determine impact of...
-
Bearing Capacity of aluminum bars with built-up cross section and glued or welded connections
PublicationThe paper is focused on numerical analysis and experimental test of aluminum bars with glued and welded connections between separate members. The connection properties were tested experimentally. The numerical analysis were conducted for the beam and shell model of the structure. The shape and magnitude of initial geometric imperfection was taken into account
-
The buckling analysis of a cold-formed steel C-sectional column resting on an elastic foundation
PublicationThe paper is focused on stability analysis of different models of steel cold-formed C-section column. The analysed element may be applied as a primary load-bearing member in steel trusses or silo columns. The column can be used as a support for a wall of roof plates made of corrugated sheets. The wall sheeting that restrains the column against buckling may be considered as an elastic foundation. Due to the design solutions the...
-
Characterization of rectangular waveguide with a pseudochiral omega slab
PublicationMetodę dopasowania rodzajów zastosowano do rozwiązania falowodu prostokątnego zawierającego materiał pseudochiralny typy Omega. Zdefiniowano własności rodzajów pola w badanej prowadnicy oraz zauważono wystąpienie efektu przemieszczenia pola. Określono pełnofalową macierz rozproszenia sekcji badanego falowodu oraz porównano wyniki symulacji charakterystyk transmisyjnych sekcji z eksperymentem. W oparciu o uzyskane wyniki dokonano...
-
Experimental Research of Implant-Fascia Connections
PublicationW pracy przedstawiono wyniki identyfikacji siły zrywającej połączenie implantu z powięzią wykonane z użyciem różnych typów łączników: zszywek lub szwów chirurgicznych. Rozważono pięć typów łączników i pięć typów implantów.
-
Influence of a Lighting Column in the Working Width of a W-Beam Barrier on TB51 Crash Test
PublicationRoad equipment, such as, e.g., road safety barriers and lighting columns, are subject to certification according to the EN1317 standard to be allowed for use on European roads. In engineering practice, due to the terrain conditions, there are cases where other road equipment is installed within the working width of road safety barriers. Such situations are not considered during the certification process. Hence, the aim of this...
-
Retention modeling of some saccharides separated on an amino column.
PublicationUsing an amino column (Supelcosil LC-NH2) and different mixtures of acetonitrile-water, quantitative structure-retention relationship models are discussed. These models are based on computed molecular descriptors representing numerically structured features of some saccharides. The obtained results are underlining the lipophilicity/hydrophilicity balance, and how this is controlling the separation of the saccharides. The resulting...
-
Enhancing seismic performance of rigid and semi-rigid connections equipped with SMA bolts incorporating nonlinear soil-structure interaction
PublicationNowadays, using smart connections can improve the performance of buildings with some recentering features that are from the superelastic behavior of Shape Memory Alloys (SMAs). It seems that there is different rigidity between the designed connection and the real one in Steel Moment-Resisting Frames (SMRFs), which can be considered as a problematic issue due to the importance of connections in seismic performance assessment. This...
-
Bifurcation of equilibrium forms of a gas column rotating with constant speed around its axis of symmetry
PublicationWe will be concerned with the problem of deformation of the lateral surface of a column that rotates with constant speed around its axis of symmetry. The column is filled by a gas and our goal is to investigate the deformation of the lateral surface depending on the pressure of the gas.
-
Parameter estimation of a discrete model of a reinforced concrete slab
Publication -
Differences and mutual connections of the transport safety systems
PublicationKażdego dnia w systemie transportowym na świecie ginie ponad 3 tys. osób, z czego większość w wypadkach drogowych. Z punktu widzenia zarządzania bezpieczeństwem, każdy z systemów gałęziowych jest zorganizowany w inny sposób. Dotyczy to baz danych, instytucji zarządzających infrastrukturą transportową i badających wypadki, systemów monitorujących ruch pojazdów, pociągów i statków. Pomimo wielu odrębności w funkcjonowaniu poszczególnych...
-
Radar technique in application of interlayer identification connections
PublicationOne of important issues in pavement construction is to ensure that layers applied directly one on top of the other make up a continuous whole and form an integral construction complex. An appropriate interlayer connection plays here significant role ensuring proper transmission of distortions generated by wheels of vehicles to lower layers and preventing water penetration between the layers. In case of damaged pavements where lack...
-
Stability and limit load analysis of a cold-formed channel section column
PublicationThe paper presents stability and limit load analysis of a steel column 1440 mm high of a cold-formed channel section, subjected to a combination of compression and bending. Experimental results were compared to the resistance of a code procedure and to the outcome of numerical non-linear analysis. Comparison was made of numerical solutions by means of static (Riks) and dynamic (Explicit and Implicit) methods. Perfectly elastic...
-
Production of tropane alkaloids in Hyoscyamus niger (black henbane) hairy roots grown in bubble-column and spray bioreactors
PublicationHairy root cultures of Hyoscyamus niger were cultivated in shake-flasks, a bubble-column bioreactor and a hybrid bubble-column/spray bioreactor and evaluated for alkaloid production.
-
Normal stress distribution in built‑up cold‑formed column in relation to interconnecting bolt spacing
PublicationIn order to increase a stiffness of cold-formed steel (CFS) elements it is practised to built-up the cross-section. In the analysed case, a main element is strengthened by adding extra chord in contact partially along the column. This additional chord acts as a longitudinal stiffener connected with the main section by series of bolts. Authors check whether rules applied over the years, for hot-rolled elements, can be indiscriminately...
-
Electromagnetic properties of a dielectric slab with an embedded silver nanowire grating
Publication -
Scattering of the plane wave from a periodically perforated dielectric slab
Publication -
Electromagnetic characterization of a silver nanowire grating embedded into a dielectric slab
Publication -
The optimisation of analytical parameters for routine profiling of antioxidants in complex mixture by HPLC coupled post-column derivatisation
PublicationIntroduction: The wide application of natural and artificial antioxidants in food, cosmetic and pharmaceutical industry as well as the recognition of the importance of food antioxidants for supporting human health created demand for reliable and industrially applicable methods of determining antioxidative activity. This requirement can be fullfilled with the recently proposed HPLC-post-column derivatisation approach enabling the...