Search results for: electromagnetic compatibility
-
Improvement of impulse radio electromagnetic compatibility
PublicationPublikacja zawiera opis jednej z możliwych technik modyfikacji widma sygnału ultraszerokopasmowego radia impulsowego na przykładzie standardu IEEE 802.15.4a, opartą o zmianę struktury sekwencji generowanych impulsów o bardzo krótkim czasie trwania. Technika ta może zmniejszyć ryzyko wzajemnych zakłóceń pomiędzy nowymi urządzeniami ultraszerkopasmowymi a istniejącymi urządzeniami radiokomunikacji wąskopasmowej
-
Concept of Compatibility Region for the Evaluation of IR UWB Electromagnetic Compatibility
PublicationThis paper presents a new proposal for the unified evaluation of ultra wideband and narrowband radio communication systems electromagnetic compatibility, called “compatibility region”. The idea of compatibility region is based on the relation between the ratio of narrowband to ultra wideband signal power in a receiver and some transmission quality indicators (bit error rate, effective data rate).
-
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY
Journals -
Electromagnetic Compatibility Magazine, IEEE
Journals -
Naval electromagnetic compatibility investigations by use of topological model
PublicationPublikacja przedstawia zagadnienie uwarunkowań kompatybilnościowych na statkach. Ze względu na trudności jakie stwarza analiza EMC dużych obiektów, środowisko elektromagnetyczne okrętów jest zwykle dzielone na fragmenty analizowane oddzielnie. Referat przedstawia topologiczny model środowiska elektromagnetycznego w formie macierzowej, który pozwala na kompleksową analizę zagadnień kompatybilnościowych wielu systemów pracujących...
-
Electromagnetic compatibility tests of warship antitorpedo jamming system
PublicationW artykule przedstawiono zagadnienie interferencji elektromagnetycznych na okręcie wojennym spowodowanych pracą antytorpedowego systemu zakłócającego. W warunkach laboratoryjnych, dla wybranej konfiguracji systemu, zostały przeprowadzone badania kompatybilnościowe i na podstawie otrzymanych rezultatów zostały sformułowane wnioski praktyczne.
-
Topological Model of an Electromagnetic Environment Inside a Ship for Electromagnetic Compatibility (EMC) Analysis
PublicationThe mutual electromagnetic (EM) interactions between electrical and electronic devices in a segmented space, such as a ship's environment, ared described. Firstly, the topological structure of a ship's segmented internal environment, which consists of many electrical screening walls (shielding planes), is presented. Then, taking into account the ship's topological structure, a general description of the EM disturbance distribution,...
-
IEEE Letters on Electromagnetic Compatibility Practice and Applications
Journals -
IEEE Electromagnetic Compatibility Magazine
Journals -
Reliability-Operational Analysis of the LED Lighting Module Including Electromagnetic Interference
Publication -
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Experimental and numerical investigation of crosstalk effect in coupled coplanar waveguides - part II: Multimode coupled line representation
PublicationW pracy przedstawiono metodę analizy nieidealności połączenia poszczegółnych fragmentów rozłożonego ekranu na zjawisko przesłuchu w strukturze sprzężonych falowodów koplanarnych z uziemionym centralnym paskiem. Analiza bierze pod uwagę efekty dyspersji oraz wielorodzajową naturę rozchodzenia się fali elektromagnetycznej w strukturze wieloprzewodowej. Teorię zweryfikowano praktycznie uzyskując bardzo dobrą zgodność pomiędzy wynikami...
-
Experimental and numerical investigation of crosstalk effect in coupled coplanar waveguides - part i: bi-mode coupled line representation
PublicationW pracy przedstawiono analizę zjawiska przesłuchu w strukturze sprzężonych falowodów koplanarnych. Analiza wykorzystując metodę przestrzeni widmowej i bazując na dwurodzajowym modelu pary linii sprzężonych uwzględnia efekty dyspersji obserwowane w zakresie wysokich częstotliwośći. Przedyskutowano zagadnienie sposobu definicji impedancji charakterystycznych dla prowadzonych rodzajów pola. Wyniki modelowania numerycznego potwierdzono...
-
An Efficient PEEC-Based Method for Full-Wave Analysis of Microstrip Structures
PublicationThis article introduces an efficient method for the equivalent circuit characterization and full-wave analysis of microstrip structures, leveraging the full-wave partial element equivalent circuit (PEEC). In particular, the multilayered Green's function is evaluated using the discrete complex-image method (DCIM) and employed to establish the mixed potential integral equations. The proposed strategy considers time delays for the...
-
CM Voltage Compensators for Power Electronic Interfaces
PublicationThe experimental results presented in the paper have shown that the application of the PEIs might cause EMC related problems, especially in the case of the application of a group of connected converters. The most convenient way to reduce EMI currents and prevent aggregation of EMI currents introduced by a group of converters is through passive compensation of voltage interference sources inside of the single converters. In the...
-
Objective selection of minimum acceptable mesh refinement for EMC simulations
PublicationOptimization of computational electromagnetics (CEM) simulation models can be costly in both time and computing resources. Mesh refinement is a key parameter in determining the number of unknowns to be processed. In turn, this controls the time and memory required for a simulation. Hence, it is important to use only a mesh that is good enough for the objectives of the simulation, whether for direct handling of high-fidelity EM...
-
Stanisław Galla dr inż.
PeopleStanisław Galla was born in 1970 in Gdańsk. He graduated from the Secondary Technical School of Mechanical and Electrical Engineering in Gdansk (1990). He studied at the Faculty of Electrical Engineering at Gdansk University of Technology (graduated in 1996). His PhD thesis entitled "Methodology for increasing the accuracy of low frequency measurements of periodic disturbance indicators in low voltage networks" was defended in...
-
Jacek Stefański prof. dr hab. inż.
PeopleJJacek Stefański received M.Sc., Ph.D. and D.Sc. degrees in telecommunications engineering from Gdansk University of Technology (GUT), Poland, in 1993, 2000 and 2012, respectively. Awarded title of Professor by the President of Poland in 2020. Currently, he works as a professor at the Department of Radio Communication Systems and Networks (DRCSN) in GUT. From 2005 to 2009, he worked as an assistant professor in the National Institute...
-
FPGA-Based System for Electromagnetic Interference Evaluation in Random Modulated DC/DC Converters
PublicationField-Programmable Gate Array (FPGA) provides the possibility to design new “electromagnetic compatibility (EMC) friendly” control techniques for power electronic converters. Such control techniques use pseudo-random modulators (RanM) to control the converter switches. However, some issues connected with the FPGA-based design of RanM, such as matching the range of fixed-point numbers, might be challenging. The modern programming...
-
Beata Pałczyńska dr inż.
People -
The standard radiated immunity test of an astable multivibrator at a normative field strength
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz are performed...
-
High Frequency Harmonics Emission of Modern Power Electronic AC-DC Converters
PublicationModern AC/DC converters with bidirectional power flow employing PWM boost topology generate harmonic distortions of input current in relatively high frequency range tightly related to modulation carrier frequency. These frequencies and its multiples in typical applications are usually located in frequency range from single up to several of kHz. Increased harmonic emission in this frequency range can easily and harmfully influence...
-
High Frequency Conducted Emission in AC Motor Drives Fed By Frequency Converters: Sources and Propagation Paths
PublicationProvides a concise and thorough reference for designing electrical and electronic systems that employ adjustable speed drives Electrical and electronic systems that employ adjustable speed drives are being increasingly used in present-day automation applications. They are considered by many application engineers as one of the most interfering components, especially in a contemporarily faced industrial environment. This book fills...
-
The radiated immunity test of an astable multivibrator at over-normative field strengths
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz were performed...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
PublicationThis paper presents different topologies of buck-boost converters with passive input networks that have alternative topologies; this is known in the literature as a Z-source inverter. Alternative passive networks were named by the authors as T-inverters; these improve output voltage regulation of the PWM inverters. T-inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage...
-
The radiated immunity test of an astable multivibrator for various supply voltages
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator supplied from a power supply with an output voltage of 6V and 7.5 V. Tests of immunity of electronic systems to radiated radio frequency (RF)...
-
The radiated immunity test of an astable multivibrator in the frequency range from 100 MHz to 300 MHz
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 100 MHz to 300 MHz were...
-
EMI mitigation of GaN power inverter leg by local shielding techniques
PublicationThis paper presents local shielding techniques applied to a half-bridge inverter leg with the aim to reduce the common mode (CM) current noise at converter’s DC input. The research study is conducted for 650V Enhancement mode Gallium Nitride (GaN) power transistor switches. Main contributors of parasitic capacitances referred to the inverter-leg middle point node are identified. Then, shielding solutions are proposed to reduce...
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...
-
Paweł Derkacz
PeoplePawel B. Derkacz was born in Miastko, Poland, in 1993. He received the B.Sc. and M.Sc. degrees in electrical engineering from the Gdansk University of Technology (GUT), Gdansk, Poland, in 2016 and 2017, respectively. In October 2017, he joined the Faculty of Electrical and Control Engineering at GUT Gdansk. In June 2019, he joined the Grenoble Electrical Engineering Laboratory (G2Elab) at Grenoble Institute of Technology (Grenoble...
-
High Frequency Harmonics Emission in Smart Grids
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Arsalan Muhammad Soomar Doctoral Student
PeopleHi, I'm Arsalan Muhammad Soomar, an Electrical Engineer. I received my Master's and Bachelor's Degree in the field of Electrical Engineering from Mehran University of Engineering and Technology, Jamshoro, Sindh, Pakistan. Currently enrolled as a Doctoral student at the Gdansk University of Technology, Gdansk, Poland. Also worked in Yellowlite. INC, Ohio as a Solar Design Engineer. HEADLINE Currently Enrolled as a Doctoral...
-
The Assessment of the Influence of Low-Frequency Electromagnetic Fields Originated from the Power Infrastructure on Humans’ Health
PublicationThe objective of this study is to assess the impact of low-frequency electromagnetic fields (LF EMFs) generated by power infrastructure on the nearby environment. Measurements of electric (E) and magnetic (H) field intensities were conducted around high-voltage power lines, transformer stations and facilities related to them. Numerical simulations were also performed to model the distribution of the field values around real buildings...
-
AC motor feeding cable consequences on EMC performance of ASD
PublicationHigh level of conducted EMI emissions of adjustable speed drives (ASD) is one of the most difficult problems in contemporary applications. Many investigations are carried out in order to find more effective methods allowing to predict this emission at early stage of design, and therefore to predict adequate countermeasures. This paper deals with the method which allows to estimate by simulation the influence of motor feeding cable...
-
Zero phase shift digital filtering for assessment of exposure to non-sinusoidal magnetic fields
PublicationAccuracy of assessment of human body exposure to magnetic fields is affected by several uncertainty sources. One of them is estimation of the total exposure to non-sinusoidal fields. Standard methods can be implemented using analogue or digital filters that introduce a phase shift that affect the result of total exposure level estimation. The paper presents a new method that allows performing more precise assessment of exposure...