Search results for: selectivity of ion-selective electrodes
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
PublicationIn potentiometry, high selectivity of the ion-selective membranes must be assured in order to reliably measure various analytes in clinical, industrial and environmental samples. Due to the toxic nature of lead(II) it is important to monitor Pb2+ distribution in natural waters. This may be achieved by implementation of ion-selective electrodes (ISEs) with high selectivity towards lead(II) and low detection limit. A great number...
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
Publication -
Equilibration Time of Solid Contact Ion-Selective Electrodes
Publication -
Kinetic Description of the Membrane–Solution Interface for Ion-Selective Electrodes
Publication -
Synthesis and application of tetrazole di and triamide derivatives in ion-selective membrane electrodes
PublicationA number of tetrazole diamides and triamides have been synthesized and applied as ion carries in ion-selective membrane electrodes. Their selectivity and sensitivity were studied towards alkali, alkaline earth, transition and heavy metal cations. it was found that membranes doped with 3 and 2-nitrophenyl octyl ether exhibit an almost theoretial Nernstian response for NH+ over relatively wide concentration range. Elestrodes with...
-
Poly(3-octylthiophene) as solid contact for ion-selective electrodes: contradictions and possibilities
Publication -
Selectivity of lithium electrodes: correlation with ion-ionophore complexstability constants and with interfacial exchange current densities
PublicationMembranowe elektrody selektywne na jony litu oparte na dwóch różnych dicyk-lohesyloamidowych jonoforach poddane zostały systematycznym badaniom. Potencjometrycznie wyznaczono wartości współczynników selektywności. Wartości stałych trwałości kompleksów z jonami litu, sodu i potasu wyznaczono metodą membran "sandwichowych". Transfer ładunków przez membranę oraz przez granicę faz membrana/roztwór badano metodą spektroskopii impedancyjnej....
-
A new phosphonium calix[4]arene for selective anion recognition: synthesis and studies in solution and in ion selective electrodes
PublicationZaprezentowana została synteza i charakteryzacja tetra (trifenylofosfoniowego) p-tert-butylkaliks[4]arenu 2. Oddziaływania z anionami były badane z użyciem (1)H oraz (31)P NMR i spektrofotometrii absorpcyjnej UV. Badania wykazały oddziaływania z anionami: CLO4-, I-, oraz SCN-. Selektywność jonoforu 2 badano również w membranowych elektrodach jonoselektywnych (ISE) PCV/o-NPOE. Elektroda zawierająca związek 2 generuje odpowiedź potencjometryczną...
-
Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective Electrodes
Publication -
Ion-selective electrodes based on p-tert-butyl-homooxacalixarene di(ethyl)amides
Publication -
Ion-selective electrodes based on p-tert-butyl-homooxacalixarene di(ethyl) amides
PublicationPochodne dietyloamidowe p-tert-butylodihomooksakaliks[4]arenu (1), p-tert-butyloheksahomotrioksakaliks[3]arenu (2) oraz p-tert-butylokaliks[4]arenu (3) były wykorzystane jako materiał aktywny w membranach elektrod jonoselektywnych w celu sprawdzenia detekcji kationów różnych rodzajów (Na+, K+, Cs+, Mg2+, Ca2+, Mn2+, Cu2+, Zn2+, Cd2+, Pb2+ oraz kation tetrametyloammoniowy). Wyznaczono charakterystyki elektrod oraz współczynniki...
-
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
Publication -
Solid-Contact Ion-Selective Electrodes with Highly Selective Thioamide Derivatives of p-tert-Butylcalix[4]arene for the Determination of Lead(II) in Environmental Samples
Publication -
Potentiometric sensor containing set of ion selective electrodes with lipid modified membranes for quality assessment of tested non-alcoholic beverages
PublicationPotentiometric sensors may be a good tool for fast quality control of commercial drinks. In this work, such a sensor, containing a set of ion-selective electrodes with lipid-modified membranes (benzylhexadecyldimethylammonium chloride monohydrate, hexadecylamine, 1-dodecanol, elaidic acid, cholesterol) was used for discrimination and quality control of non-alcoholic beverages, mainly composed of sugar and citric acid. It was found...
-
Dipodal Tetraamide Derivatives of 1,10-Diaza-18-Crown-6 and Alkylmalonic Acids—Synthesis and Use as Ionophores in Ion Selective Membrane Electrodes
PublicationNovel dipodal derivatives of an 18-membered diaza-crown ether with two diamide chains featuring methylmalonic or butylmalonic acid residues were obtained and tested as ionophores in ion-selective plasticized membrane electrodes. The objective of the study was to identify measurement conditions which ensure the most favorable performance for magnesium ion-selective electrodes. The relationship between the molar lipophilic anion...
-
Solid-Contact Ion-Selective Electrodes with Highly SelectiveThioamide Derivatives of p-tert-Butylcalix[4]arene for theDetermination of Lead(II) in Environmental Samples
PublicationThioamide derivatives of p-tert-butylcalix[4]arene were used as ionophores in the development of solid-contact ion-selective electrodes based on conducting polymer poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) which was synthesized by electrodeposition on the glassy carbon electrodes. The typical ion-selective membranes with optionally two different plasticizers [bis(2-ethylhexyl)sebacate (DOS) and 2-nitrophenyl...
-
Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo-15-crown-5) derivatives
PublicationGlassy carbon electrodes modified by conductive polymers and membrane with derivatives of bis(benzo-15-crown-5) were tested as solid contact ion selective electrodes for K+ ions concentration determination. PEDOT with PSS, Cl- and ClO4- counter ions was electrochemically deposited onto glassy carbon substrates using four different electrochemical approaches (potentiostatic, galvanostatic, potentiodynamic and potentiostatic pulses)....
-
Lower rim substituted tert-Butylcalix[4]arenes. Part 13. Interaction of calix-hydroxamates with Fe(III) and Pb(II); studies in ion-selective membrane electrodes (ISE)
PublicationPrzedmiotem pracy są badania oddziaływań pomiędzy trzema wybranymi hydroksamowymi pochodnymi t-butylo-kaliks[4]arenu i jonami metali z wykorzystaniem membranowych elektrod jonoselektywnych (ISE). Elektrody zawierające jako materiał aktywny wymienione związki jonoforowe charakteryzują się nernstowskim nachyleniem i szerokim zakresem liniowości na jony Pb(II), a także dobrą selektywnością na jony Pb(II)w stosunku do jonów UO2(II),...
-
Lower Rim Substitutedp-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based onp-tert-Butyl-calix[4]arene Thioamides
Publication -
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based on p-tert-Butyl-calix[4]arene Thioamides.
PublicationTetra podstawione tioamidowe pochodne para-tert-butylokaliks[4]arenu (1-5) zostały zastosowane jako jonofory w membranowych elektrodach jonoselektywnych (EJS) selektywne na kationy Pb(II). Wyznaczono współczynniki selektywności. Czwartorzędowe kaliks[4]aren-tioamidy (1,2) wykazują nadzwyczaj dobrą selektywność na kationy Pb(II) w porównaniu z kaliks[4]aren-amidami. Membrany z tymi ligandami wykazują dużą trwałość, a charakterystyki...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublicationLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Lower Rim Substituted p-tert-Butyl Calix[4]arenes(V). Synthesis of New 5,11,17,22-tetrakis-p-tert-Butyl-25-27-bis(dialkoxyphosphorylmethoxy)calix[4] arenes and Cation Complexation Studies in Ion Selective Membrane Electrodes.
PublicationZaprezentowano syntezę i właściwości trzech nowych związków (2-4), bis podstawionych na dolnym obrzeżu grupami z resztą fosforylową. Związki te były badane jako jonofory w membranowych elektrodach jonoselektywnych (ISE) wykazując selektywność na kationy Rb+,K+ oraz duży i płaski kation guanidyniowyG+). Badano korelację pomiędzy stereo-strukturą związków a ich selektywnością w ISE. Stałe trwałości kompleksów z kationami metali...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
O-substituted tetrahydroxamate derivatives of p-tert-butylcalix[4]arene as receptors for transition and heavy metal cations
PublicationTetrasubstituted O-hydroxamate derivatives of p-tert-butylcalix[4]arene were applied as active materials in ion-selective membrane electrodes and were tested towards Pb-selectivity. The electrodes gave near-Nernstian characteristics for Pb2+ cations. The selectivity coefficients were determined. The influence of plasticizer on the electrode behaviour was studied. The dependence of the chemical structure on selectivity coefficients...
-
Calix[4]arenes appended with thioamide moieties as powerful tool for heavy metals recognition
PublicationSelectivity of new thioamide derivatives was assessed using those ligands as sensor materials in ion-selective membrane electrodes and tested towards Pb2+ - selectivity. The influence of the nature of the thioamide function (linear, branched or cyclic substituents) on their ionophoric properties was investigated. Electrodes based on cyclic thioamide moieties are promising analytical tools for monitoring Pb2+ concentration in natural...
-
Inhibition of impurities formation in the synthesis of N-alkyltheobromines stimulated by microwave irradiation. Cationic and anionic response of membrane electrodes
PublicationN-Alkyltheobromine (1-9) derivatives were obtained by reacting theobromine with appropriate alkyl halide under microwave irradiation at 100-150 W and by conventional synthesis. Formation of by-products of oxygen atom alkylation and 1-N-alkyltheobromine ring opening were considered. The presented compounds 1-5 have been studied as ion carriers in ion-selective membrane electrodes. Selectivity of these membranes was studied towards...
-
New bis(azobenzocrown)s with dodecylmethylmalonyl linkers as ionophores for sodium selective potentiometric sensors
PublicationNovel biscrowns 1 and 2 were synthesized from 13-membered azobenzocrown ethers containing bromoalkylenoxy chains in para position relative to the azo group. The synthesized diester molecules are dodecylmethylmalonic acid derivatives differing by the linker length. The synthesized compounds have the potential of being used as sodium ionophores in ion-selective electrodes. They were characterized and used as ionophores in classic...
-
Selective detection of F- by chromogenic tetrazole receptor
PublicationA chromogenic anion host 4, containing two amide functionalities linked to azo dye and tetrazole rings was synthesized and its complexes with various anions were investigated. The results show that receptor 4 can recognize selectively biologically important F- ion. The binding affinity for F- was investigated by naked-eye colour change, UV-Vis and 1H NMR spectroscopy. Addition F- ion in CH3CN and DMSO to receptor 4 cause a colour...
-
Lower rim substituted p-tert-butyl-calix[4]arene. Part 17. synthesis, extractive and ionophoric properties of p-tert-butylcalix[4]arene appended with hydroxamix acid moieties
PublicationThe synthesis and characterization of four p-tert-butylcalix[4]arene-hydroxamic acidc are reported. The dependence of the metal ion binding, assessed by liquid extraction of the metal nitrates from water into dichloromethane in individual and competitive experiments, on the ligand structure, is presented. The results showed that those ligands could be successfully used in separation process of trnasition and heavy metals often...
-
Synthesis and properties of new 'N,'N-phenyltetrazole podand
PublicationThe synthesis of a new chromogenic N,N-phenyltetrazole receptor is reported here. The cationbinding properties of this receptor in solution were investigated by naked-eye colour change, electrochemical methods and UV-Vis spectroscopy in various solvents (CH3CN, dimethylsulphoxide (DMSO), DMSO/H2O, CH3CN/H2O and CH3CN/MeOH). In addition, the receptor was used as a sensing material in ion-selective membrane electrodes. The selectivity...
-
Calix[4]arene-Thioamides as Ionophores for Transition and Heavy Metal cations
PublicationCalix[4]arene derivatives play an important role as sensing materials in Ion Selective Electrodes(ISEs). Nowadays a high impact is put to control in natural waters the level of toxic heavy metals, like Pb ,Cd, Hg or Cu which may cause the great risk to human health. Our goal was to design and to synthesize ligands possessing ability to bind transition and heavy metal cations. The synthesis, crystal structures,extractive and ionophoric...
-
Jarosław Chojnacki prof. dr hab. inż.
PeopleBorn in 1961 in Bydgoszcz, professional education started at the Chemical Technical Highschool (I. Łukasiewicz). He graduated from the Faculty of Chemistry at the Gdańsk University of Technology in 1986, defending the work on ion-selective electrodes. Subsequent studies were related to organic and siliconorganic synthesis and, from 2002 year on, to crystallography. The doctoral thesis concerned the Silanotiolanes of coinage metals...
-
Chromogenic derivatives of new bis(phenylhydrazono-1H-tetrazol-5-yl-acetonitriles) - synthesis and properties
PublicationDerivatives of bis(phenylhydrazono-1H-tetrazol-5-yl-acetonitriles) with oxygen and sulphur atoms in the structure of aliphatic chains were successfully synthesised. The correlation between the ligand structure and its complexation properties was investigated by absorption spectroscopy. The formation of complexes of presented compounds with metal cations (Cu2+, Ni2+, Zn2+, Co2+, Fe2+ and Pb2+) was studied. Ligands 5-8 were additionally...
-
Simultaneous determination of Na+, K+, Ca2+, Mg2+ and Cl- in unstimulated and stimulated human saliva using all solid state multisensor platform
PublicationHuman saliva is one of the body fluids which collection method is relatively simple and non-invasive. The article is dedicated to assess concentration (activity) of Na+, K+, Ca2+, Mg2+ and Cl- in fresh, unstimulated or stimulated human saliva samples using single solid contact ion-selective electrodes with conventional reference electrode and self-made multisensor platform (MP) equipped with ion-selective membranes for Na+, K+,...
-
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
Wybrane aspekty oceny jakości produktów żywnościowych
PublicationPrzedstawiono wybrane aspekty oceny jakości produk tów żywnościo- wych: pojęcie jakości, wybrane metody oceny jakości ze szczególnym uwzględ- nieniem sztucznych potencjometrycznych sensorów sma ku składających się z szeregu elektrod typu ISE (Ion Selective Electrodes ) oraz ASSE (All Solid State Electrodes). Omówiono działanie sztucznych sensorów smaku. Przedstawiono 10 potencjometryczny sensor wprowadzony do obrotu hand lowego....
-
Functionalized azobenzocrown ethers as sensor materials—The synthesis and ion binding properties
PublicationNew 13- and 16-membered azobenzocrown ethers with aromatic amino, amide, ether–ester or ether–amide residue in para position to an azo moiety were obtained. Acid–base properties and ion binding ability of the colored compounds were studied by spectroscopic methods: UV–vis, fluorimetry and 1H NMR spectroscopy. Selected azobenzocrowns were tested as ionophores in ion-selective membrane electrodes (ISEs) – classic and miniature all...
-
Investigation of sour substances by five-channel potentiometric taste sensor containing all-solid-state-electrodes ( ASSEs)
PublicationAn elaboration of taste sensor for discrimination of different food products is of great importance for food industry. Potentiometric taste sensor containing ion selective electrodes with lipid/polymer membranes has already been applied commercially in food industry. However, time-consuming and demanding preconditioning method of ions selective electrodes as well as maintenance of electrodes’ bodies are disadvantages of this taste...
-
INVESTIGATION OF SOUR SUBSTANCES BY FIVE-CHANNEL POTENTIOMETRIC TASTE SENSOR CONTAINING ALL-SOLID-STATE- ELECTRODES (ASSEs)
PublicationAn elaboration of taste sensor for discrimination of different food products is of great importance for food industry. Potentiometric taste sensor containing ion selective electrodes with lipid/polymer membranes has already been applied commercially in food industry. However, time-consuming and demanding preconditioning method of ions selective electrodes as well as maintenance of electrodes’ bodies are disadvantages of this taste...
-
Chromogenic macrocyclic derivatives of azoles - synthesis and properties,
PublicationNew azocrown ethers comprising imidazoles in the macrocycle have been synthesized. Imidazole, 2-methyl-, 4-methyl-, and 4-phenylimidazole were incorporated to form macrocyclic units by coupling with the appropriate bis-diazonium salts. The syntheseswere performed under high dilution conditions. The X-ray structure of a water adduct of the 21-membered crown ether derivative of 4-methylimidazole 8 has been solved. Metal...
-
Azomacrocyclic derivatives of imidazole: synthesis, structure, and metal ion complexation properties
PublicationNew azocrown ethers comprising imidazoles in the macrocycle have been synthesized. Imidazole, 2-methyl-, 4-methyl-, and 4-phenylimidazole were incorporated to form macrocyclic units by coupling with the appropriate bis-diazonium salts. The syntheseswere performed under high dilution conditions. The X-ray structure of a water adduct of the 21-membered crown ether derivative of 4-methylimidazole 8 has been solved. Metal...
-
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
Azo and azoxythiacrown ethers: synthesis and properties
PublicationA series of 16- and 18-membered azo- and azoxythiacrown ethers have been synthesized by reductive macrocyclization of the respective bis(nitrophenoxy)oxaalkanes. The aromatic residues located in the polyether region of the molecule were introduced to macrocyclic skeletons and their affinities toward different groups of metal cations in ion-selective electrodes were described. X-ray structures for one dinitropodand and one azoxybenzothiacrown...
-
Calixthioamides as ionophores for transition and heavy-metal cations
PublicationThere is an increasing interest in applying p-tert-butylcalix[4]arenes as sensing materials in ion-selective electrodes(ISEs). Considerable efforts were made to design calixarenes that are selective for some heavy- or transitionmetal ions to be used in ISEs for controlling and monitoring the level of such pollutants in the environment. It has been reported that introduction of softer sulfur atoms instead of oxygen atoms in calix[4]arene...
-
Potentiometric taste sensor application for liquid product taste estimation
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiometric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
TASTE QUALITIES ESTIMATION BY TASTE SENSE AND ELECTROCHEMICAL SENSORS
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiom etric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
Self-assembly, stability and conductance of amphotericin B channels: bridging the gap between structure and function
PublicationAmphotericin B (AmB), one of the most powerful but also toxic drugs used to treat systemic mycoses, is believed to selectively permeabilize fungal cell membranes to ions in a sterol-dependent manner. Unfortunately, the structure of the biologically active AmB channels has long eluded researchers, obstructing the design of safer alternatives. Here, we investigate the structural and thermodynamic aspects of channel formation, stability,...
-
Rearrangement of azoxybenzocrowns into chromophoric hydroxyazobenzocrowns and the use of hydroxyazobenzocrowns for the synthesis of ionophoric biscrown compounds
PublicationThe Wallach rearrangement was used as a method for preparing p-hydroxyazobenzocrown ethers starting from different azoxybenzocrowns as substrates. Synthesis of a series of p-hydroxyazobenzocrowns under modified conditions and characterization of the obtained products are presented. o-Hydroxyazobenzocrowns were identified among the products of the photochemical rearrangement of azoxybenzocrowns. Novel biscrowns were synthesized...
-
How do sterols determine the antufungal activitiy of amphotericin B? Free energy of binding between the drug and its membrane targets.
PublicationAmphotericin B (AmB) is a well-known polyene antibiotic used to treat systemic fungal infections. It is commonly accepted that the presence of sterols in the membrane is essential for the AmB biological activity, that is, for the formation of transmembrane ion channels. The selective toxicity of AmB for fungal cells is attributed to the fact that it is more potent against fungal cell membranes containing ergosterol than against...