Search results for: voltage control
-
Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station
PublicationThis paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publicationhe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
Modified SPWM Technique with Zero-Sequence Voltage Injection for a Five-Phase, Three-Level NPC Inverter
PublicationThis article presents a modified sinusoidal pulse-width modulation (SPWM) scheme for a five-phase, three-level neutral-point-clamped inverter. The modulation scheme deploys a modified min–max function to inject the zero-sequence components into the reference modulating signals; hence enabling the effective utilization of the DC-link voltage. Balanced split-input DC-link voltages were achieved through further incorporation of adjustable...
-
Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection
PublicationThis paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...
-
VSC converters control for offshore wind farms HVDC grid connection
PublicationThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
-
Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation
PublicationIn this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublicationThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Improving voltage levels in low-voltage networks with distributed generation – case study
PublicationThe use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublicationRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublicationThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Impact of R/X ratio of distribution network on selection and control of energy storage units
PublicationThe interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...
-
Space Vector Pulsewidth Modulation Strategy for Multilevel Cascaded H-Bridge Inverter With DC-Link Voltage Balancing Ability
PublicationSpace vector pulsewidth modulation (SVPWM) algorithms for cascaded H-bridge multilevel (CHB ML) inverter usually provide the possibility of using several combinations of active voltage vectors to generate the same output voltage vector. For preselected H-bridges, some of them may generate output voltages opposite to the assumed direction. This results in the change of the dc-link voltages of these H-bridges in the opposite direction...
-
Voltage Transients Transfer over Medium Voltage Instrument Transformers
PublicationThis paper presents voltage harmonic transfer accuracy problems through voltage transformers which are used in power quality monitoring systems in medium and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid has been tested in the conducted disturbances...
-
Voltage Harmonics Transfer through Medium Voltage Instrument Transformers
PublicationVoltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...
-
Single-phase, Five-level Inverter with SPWM-Based Neutral Point Voltage Balancing Scheme
PublicationMultilevel inverter topologies provide several advantages over two-level inverter configuration. These benefits are the reason for the growing interest in multilevel topologies among research society. One of the most popular topological concepts (diode and active switch clamping) requires neutral-point potential balancing due to series-connected capacitor banks across the input dc link in such derived inverter configurations. This...
-
Problems with microprocessor voltage-to-frequency and frequency-to-voltage converters implementation
PublicationThe article presents the problems of digital voltage-to-frequency and frequency-to-voltage processing. Transducer systems implemented in microprocessor technology are presented, the timing of signals and functioning algorithms are discussed. An analysis of processing errors has been performed and the results of experimental studies of realized systems are presented.
-
Sensorless predictive control of three-phase parallel active filter
PublicationThe paper presents the control system of parallel active power filter (APF) with predictive reference current calculation and model based predictive current control. The novel estimator and predictor of grid emf is proposed for AC voltage sensorless operation of APF, regardless of distortion of this voltage. Proposed control system provides control of APF current with high precision and dynamics limited only by filter circuit parameters....
-
Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation
PublicationThe constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....
-
High Performance Control of AC Drives with Matlab/ Simulink
PublicationExplore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...
-
Grid-Forming Operation of Energy-Router Based on Model Predictive Control with Improved Dynamic Performance
PublicationThe focus of this study is on the grid-forming operation of the Energy Router (ER) based on Model Predictive Control (MPC). ER is regarded as a key component of microgrids. It is a converter that interfaces the microgrid (s) with the utility grid. The ER has a multiport structure and bidirectional energy flow control. The ER concept can be implemented in Nearly Zero-Energy Buildings (NZEB) to provide flexible energy control. A...