Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Data from environmental sensors installed in two locations
Open Research DataThe dataset contains data gathered from environmental sensors installed in two locations:
-
What entrepreneurs think about tax optimization?
Open Research DataThe study conducted on a group of 259 entrepreneurs concerned the behavioral attitudes of business owners regarding their opinion on tax optimization. From the study we will learn, among others, how tax optimization is defined according to entrepreneurs, their attitude towards it, as well as what optimization actions they have taken so far.
-
Electrochemical impedance spectroscopy spectra measured at 800 °C, 750 °C and 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrode sintered at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C; 750°C and 700 °C (synthetic air). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 800 °C, 750 °C and 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrode sintered at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C; 750°C and 700 °C (synthetic air). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 800 °C, 750 °C and 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrode sintered at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C; 750°C and 700 °C (synthetic air). Results converted to electrode surfaces area and dived by two electrodes.
-
Light transmission measurement through the fluidized bed photoreactor
Open Research DataDataset contains light transmission measurements through the fluidized bed photoreactor. Two sources of light were used: UV-LEDs and UV fluorescent. Measurements were performed at different air flows: 0, 80, 160 and 240 ml/min. The detailed measurement and equipment data was described in measurment info.txt file.
-
X-ray diffractometry results of the Sr0.86Ti0.65Fe0.35O3 powder
Open Research DataThis dataset contains results of X-ray diffractometry mesurement (XRD) of the Sr0.86Ti0.65Fe0.35O3-d (STF35) powder. The phase composition of the investigated STF35 powder was analyzed by XRD at room temperature. It confirms the formation of the cubic perovskite oxide phase. Calculated average lattice constant is a 3.90882(1) Å, with Goodness of Fit...
-
Series resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces area.
-
Influence of sintering temperature of porous SrTi0.30Fe0.70O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Influence of sintering temperature of porous SrTi0.50Fe0.50O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Influence of sintering temperature of porous SrTi0.65Fe0.35O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Structural and luminescence properties of B2O3-Bi2O3+10AlF3 glasses doped with Eu3+/Dy3+ ions
Open Research DataThe attached data contains the results of measurements of B2O3-Bi2O3 and B2O3-Bi2O3+10AlF3 glasses doped with Eu3+ and Dy3+ ions in different molar ratios. Glasses were synthesized by the melt quenching technique. On their basis, the structural, optical, and luminescence properties of synthesized samples were characterized. The dataset includes XRD,...
-
AVHRR Level1CD covering Baltic Sea area year 2005
Open Research DataThe dataset contains data derived from recordings of the AVHRR/3 radiometer operating on board the NOAA POES (Polar Orbiting Environmental Satellites) Series - 5th Generation Satellites covering the Baltic Sea area. The satellite data was recorded in the years 2000-2012 directly by the HRPT station installed at the University of Gdańsk. The registration...
-
AVHRR Level1CD covering Baltic Sea area year 2004
Open Research DataThe dataset contains data derived from recordings of the AVHRR/3 radiometer operating on board the NOAA POES (Polar Orbiting Environmental Satellites) Series - 5th Generation Satellites covering the Baltic Sea area. The satellite data was recorded in the years 2000-2012 directly by the HRPT station installed at the University of Gdańsk. The registration...
-
AVHRR Level1CD covering Baltic Sea area year 2003
Open Research DataThe dataset contains data derived from recordings of the AVHRR/3 radiometer operating on board the NOAA POES (Polar Orbiting Environmental Satellites) Series - 5th Generation Satellites covering the Baltic Sea area. The satellite data was recorded in the years 2000-2012 directly by the HRPT station installed at the University of Gdańsk. The registration...
-
AVHRR Level1CD covering Baltic Sea area year 2002
Open Research DataThe dataset contains data derived from recordings of the AVHRR/3 radiometer operating on board the NOAA POES (Polar Orbiting Environmental Satellites) Series - 5th Generation Satellites covering the Baltic Sea area. The satellite data was recorded in the years 2000-2012 directly by the HRPT station installed at the University of Gdańsk. The registration...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=6.2, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=7.3, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=2.1, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...