Filters
total: 709
filtered: 493
Search results for: ORBITAL TRAUMA
-
Static and dynamic modelling blow- out type trauma of orbital wall
PublicationAuthors of the paper present initial results of finite element analysis of a blow-out type trauma of orbital wall. The research is liked with laboratory tests for the Young’s modulus of bones evaluation. In the finite element analysis the neighbourhood of orbital wall is modelled by triangle thin shell finite elements. In the paper results of nonlinear static and transient dynamic analysis (including damping) are compared. The...
-
Orbital blowout trauma occurring at the workplace – clinical, biomechanical and legal aspects
PublicationIntroduction and objective: Craniofacial injury at the workplace may lead to orbital blowout fractures. The aim of the study is the development of own numerical model of the eye orbit, assessment of the damage zones, and comparing them with clinical examinations. In addition, the current legal status of patients after injuries is presented Material and methods: In laboratory tests performed on bones collected from the upper and...
-
Sophistication assessment of existing FEM models of orbital blowout trauma: Is models valuation justified?
PublicationAfter a thorough study of the work entitled “Development and validation of an optimized finite element model of the human orbit”, some doubts aroused concerning the sophistication assessment of the existing finite element method (FEM) models of orbital blow-out. Although the work was unquestionably innovative, and the results were not only fascinating but also invaluable, the authors stated that their model was the most sophisticated...
-
Nonlinear dynamic analysis of the pure “buckling” mechanism during blow-out trauma of the human orbit
Publication -
Validation of Hydraulic Mechanism during Blowout Trauma of Human Orbit Depending on the Method of Load Application
PublicationThe more we know about mechanisms of the human orbital blowout type of trauma, the better we will be able to prevent them in the future. As long as the buckling mechanism’s veracity is not in doubt, the hydraulic mechanism is not based on equally strong premises. To investigate the correctness of the hydraulic mechanism’s theory, two different methods of implementation of the hydraulic load to the finite element method (FEM) model...
-
Nonlinear dynamic analysis of the pure “buckling” mechanism during blow-out trauma of the human orbit
PublicationConsidering the interplay between orbital bones and intraorbital soft tissues, commonly accepted patterns of the blow-out type of trauma within the human orbit require more thorough investigation to assess the minimal health-threatening impact value. Two different three-dimensional finite element method (FEM) models of the human orbital region were developed to simulate the pure “buckling” mechanism of orbital wall fracture in...
-
Trauma relacyjna
PublicationCelem artykułu jest krótkie przedstawienie aktualnej wiedzy na temat definicji traumy relacyjnej, miejsca w klasyfikacjach, rozpowszechnienia, konsekwencji oraz stosowanych metod terapeutycznych. Raporty z wielu krajów informują, iż w relacji z dorosłymi, zwykle rodzicami, od których dziecko jest zależne przez wiele lat, może dochodzić do różnych form krzywdzenia związanych nie tylko z przemocą, ale także z zaniedbaniem w sferze...
-
Successive orbital ordering transitions in NaVO2
PublicationPomiary właściwości fizycznych NaVO2, który charakteryzuje się trójkątną siecią krystalograficzną, pokazują dwa przejścia typu orbitalnego. W temperaturze 98 K w systemie wystepuje przejście drugiego rodzaju. Natomiast poniżej 93 K obserwowane jest przejście pierwszego rodzaju.
-
Successive Orbital Ordering Transitions inNaVO2
Publication -
Posttraumatic Orbital Emphysema: A Numerical Model
PublicationOrbital emphysema is a common symptom accompanying orbital fracture. The pathomechanism is still not recognized and the usually assumed cause, elevated pressure in the upper airways connected with sneezing or coughing, does not always contribute to the occurrence of this type of fracture. Observations based on the finite model (simulating blowout type fracture) of the deformations of the inferior orbital wall after a strike in...
-
Diasporic Identity in the Face of Trauma — Diasporic Identity and the Second World War Trauma in Kerri Sakamoto’s “The Electrical Field” (1998)
Publication -
The experience of movement in orbital space architecture: A narrative of weightlessness
PublicationBased upon a combination of architectural theories, the knowledge of space environment, and psychology of isolated and confined environments, this qualitative research aims to study orbital space settlement in a way to get the built space congenial to the human experience of movement. In this sense, sensors, self-propulsion or mechanical actuators, the inhabitant’s mental and visual capacity for movement, as well as the represented...
-
The experience of movement in orbital space architecture: A narrative of weightlessness
PublicationBased upon a combination of architectural theories, the knowledge of space environment, and psychology of isolated and confined environments, this qualitative research aims to study orbital space settlement in a way to get the built space congenial to the human experience of movement. In this sense, sensors, self-propulsion or mechanical actuators, the inhabitant’s mental and visual capacity for movement, as well as the represented...
-
Which airways management technique is optimal for trauma patient ventilation?
Publication -
The allergic and irritating reactions to metallic implants with trauma - orthopaedic patients
PublicationThe article presents the analysis of clinical operation complications after the treatment of long bones by mean of ostheosynthesis with the use of metal implants and endoprothesoplastic of hip joints.
-
Tensile and flexural moduli for human orbital wall bones – comparative study
PublicationThe main aims of the current research were: (1) to analyze in detail the tensile modulus and ultimate tensile strength (UTS) of orbital wall bones separately for the left and right orbit of the same cadaver and (2) to compare the obtained results with a flexural modulus of the left and right orbit reported earlier by A. C. van Leeuwen et al. [14]. A set of 54 specimens of orbital superior and/or medial walls harvested from 16 human...
-
Odontogenic orbital cellulitis in a young man with complete vision loss – a case report
Publication -
Electronic and dynamical properties of CeRh2As2 : Role of Rh2As2 layers and expected orbital order
Publication -
Tensile modulus of human orbital wall bones cut in sagittal and coronal planes
PublicationIn the current research, 68 specimens of orbital superior and/or medial walls taken from 33 human cadavers (12 females, 21 males) were subjected to uniaxial tension untill fracture. The samples were cut in the coronal (38 specimens) and sagittal (30 specimens) planes of the orbital wall. Apparent density (ρapp), tensile Young’s modulus (E-modulus) and ultimate tensile strength (UTS) were identified. Innovative test protocols were...
-
Destruction of shell structures under the dynamic load on the human skull trauma basis
PublicationThe main aim of this work is to investigate patterns of potential orbital bone fractures due to mechanical injuries. The solution of the main problem is followed by analysis of several testing examples having straight correlation with civil engineering structures, in which materials of wide range of stiffness are applied. To solve the main problem, the three-dimensional finite element method (FEM) model of the orbital region has...
-
Pediatric trauma and emergency surgery: an international cross-sectional survey among WSES members
Publication -
Diversity and ethics in trauma and acute care surgery teams: results from an international survey
Publication -
Changes of color coordinates of biological tissue with superficial skin damage due to mechanical trauma
Publication -
Custom-Made Antibiotic Cement Nails in Orthopaedic Trauma: Review of Outcomes, New Approaches, and Perspectives
Publication -
Spin and Orbital Effects on Asymmetric Exchange Interaction in Polar Magnets: M(IO3)2 (M = Cu and Mn)
PublicationMagnetic polar materials feature an astonishing range of physical properties, such as magnetoelectric coupling, chiral spin textures, and related new spin topology physics. This is primarily attributable to their lack of space inversion symmetry in conjunction with unpaired electrons, potentially facilitating an asymmetric Dzyaloshinskii–Moriya (DM) exchange interaction supported by spin–orbital and electron–lattice coupling. However,...
-
Time for a paradigm shift in shared decision-making in trauma and emergency surgery? Results from an international survey
Publication -
Traumatized women’s infants are bigger than children of mothers without traumas
Publication -
Fiberoptic intubation or video tube for trauma patient intubation—which method to choose? Randomized crossover manikin trial
Publication -
Synthesis and Selected Properties of Ester Elastomer Containing Sorbitol
Publication -
Ordinal pattern statistics for the assessment of heart rate variability
PublicationThe recognition of all main features of a healthy heart rhythm (the so-called sinus rhythm) is still one of the biggest challenges in contemporary cardiology. Recently the interesting physiological phenomenon of heart rate asymmetry has been observed. This phenomenon is related to unbalanced contributions of heart rate decelerations and accelerations to heart rate variability. In this paper we apply methods based on the concept...
-
The Efficiency of Polish Stock Market: Ordinal Patterns Approach
PublicationZunino et al. analyzed the problem of discrimination of developed and emergent markets by the use of ordinal patterns methods: number of forbidden patterns and ordinal pattern probability distribution as a basis for entropy and statistical measure of complexity. In this paper we apply the same methodology for the analysis of Polish stock market (index WIG). The results indicate that Polish market belongs neither to developed, nor...
-
Implant system for treatment of the orbital floor defects of blowout fractures in the maxillofacial region using polypropylene yarn and bioactive bone cement
PublicationFractures in the craniofacial region are a serious problem in terms of treatment. The most reasonable solution is the use of individual implants dedicated to a specific patient. The aim of this study was to develop the implant system specifically for treatment of the orbital floor defects of blowout fractures of maxillofacial region, using polypropylene yarn and bone cement. Three types of bone cement were used to fix the polypropylene...
-
Existence of periodic orbits for a perturbed vector field
PublicationPrzy nałożeniu pewnego warunku na odwzorowanie Poincarego, wyrażonego w języku indeksów iteracji, dowodzi się istnienia orbit periodycznych dla zaburzonego pola wektorowego.
-
Rigorous numerics for critical orbits in the quadratic family
PublicationWe develop algorithms and techniques to compute rigorous bounds for finite pieces of orbits of the critical points, for intervals of parameter values, in the quadratic family of one-dimensional maps fa(x)=a−x2. We illustrate the effectiveness of our approach by constructing a dynamically defined partition P of the parameter interval Ω=[1.4,2] into almost 4 million subintervals, for each of which we compute to high precision the...
-
Surgeons’ perspectives on artificial intelligence to support clinical decision-making in trauma and emergency contexts: results from an international survey
Publication -
Finding Valence Antibonding Levels while Avoiding Rydberg, Pseudo-continuum, and Dipole-Bound Orbitals
Publication -
Correction: Surgeons’ perspectives on artificial intelligence to support clinical decision-making in trauma and emergency contexts: results from an international survey
Publication -
Trauma wojenna na przestrzeni wieków. O człowieku w doświadczeniu granicznym przez pryzmat tekstów źródłowych i literackich
Publication -
TiCoCrFeMn (BCC + C14) High-Entropy Alloy Multiphase Structure Analysis Based on the Theory of Molecular Orbitals
Publication -
Computer assisted method for proving existence of periodic orbits
Publication -
The Conley Index and Rigorous Numerics for Attracting Periodic Orbits
Publication -
Fixed orbit index for equivariant maps
Publication -
The Symmetry of GPS Orbit Ascending Nodes
Publication -
Gelatin and gelatin/starch-based films modified with sorbitol for wound healing
PublicationGelatin-based films modified with sorbitol were produced from gelatin solution or gelatin/starch blends using a simple and low-cost solvent casting method, and subsequently, their physicochemical, mechanical, and biocompatibility properties were characterized. This work focused on developing and optimizing a biopolymeric blend to improve the pure biopolymers’ properties for potential biomedical applications such as wound dressing....
-
Connecting orbits for a periodically forced singular planar Newtonian system
PublicationW niniejszym artykule badamy problem istnienia i krotności rozwiązań homoklinicznych i heteroklinicznych dla nieautonomicznych układów Newtonowskich na płaszczyźnie z potencjałem okresowym ze względu na zmienną czasową, mającym maksimum globalne właściwe przyjmowane w dwóch punktach płaszczyzny i punkt osobliwy (studnię nieskończonej głębokości), w otoczeniu którego potencjał spełnia warunek Gordona (gradient potencjału ze względu...
-
Homoclinic and Heteroclinic Orbits for a Class of Singular Planar Newtonian Systems
PublicationThe study of existence and multiplicity of solutions of differential equations possessing a variational nature is a problem of great meaning since most of them derives from mechanics and physics. In particular, this relates to Hamiltonian systems including Newtonian ones. During the past thirty years there has been a great deal of progress in the use of variational methods to find periodic, homoclinic and heteroclinic solutions...
-
Homoclinic orbits for a class of singular second order Hamiltonian systems in ℝ3
PublicationWe consider a conservative second order Hamiltonian system \ddot{q}+ ∇V(q)=0 in R3 with a potential V having a global maximum at the origin and a line l ∩ {0} = ∅ as a set of singular points. Under a certain compactness condition on V at infinity and a strong force condition at singular points we study, by the use of variational methods and geometrical arguments, the existence of homoclinic solutions of the system.
-
Homoclinic orbits for a class of singular second order Hamiltonian systems in R3
PublicationW niniejszym artykule rozważamy autonomiczny układ Hamiltonowski w 3-wymiarowej przestrzeni euklidesowej, z potencjałem osiągającym maksimum globalne właściwe równe zero w początku układu współrzędnych i mającym za zbiór punktów osobliwych prostą, która nie przechodzi przez początek układu. Przy założeniu, że potencjał spełnia pewien warunek zwartości w nieskończoności i warunek Gordona w otoczeniu prostej punktów osobliwych, stosując...
-
Ab Initio Study of the Electronic Spectrum of 7-Hydroxyquinoline
PublicationThe electronic spectrum of 7-hydroxyquinoline has been studied by using ab initio Multi-State Multi-Reference Møller-Plesset Second-Order Perturbation Theory (MSMRMP2). The energy range up to 6.5 eV is taken into consideration. The lowest π–π* transition is calculated to have an energy of 3.65 eV in good agreement with experimental data. Several other π–π* transitions are predicted to have excitation energies of 4.93, 5.20, 5.47,...
-
Development of an orbital shaker-assisted fatty acid-based switchable solvent microextraction procedure for rapid and green extraction of amoxicillin from complex matrices: Central composite design
PublicationIn this study, a cheap, fast and simple orbital shaker-assisted fatty acid-based switchable solvent microextraction (OS-FASS-ME) procedure was developed for the extraction of amoxicillin (AMOX) in dairy products, pharmaceutical samples and wastewater prior to its spectrophotometric analysis. Fatty acid-based switchable solvents were investigated for extracting AMOX. The key factors of the OS-FASS-ME procedure were optimized using...