displaying 1000 best results Help
Search results for: SMOKELESS FUEL
-
Studies of the separation performance of silanized silica gel for simulated distillation
PublicationWe present the results of investigations of the chromatographic (sorptive) properties of silanized silica gel as a stationary phase for gas chromatography used for simulated distillation. Commercially available silanized sorbent (particle diameter range 63–200 m, average pore size 60 Å) was sieved to obtain the 80–100 mesh fraction (180–150 m). The obtained results revealed that silanized silica gel allows the complete separation...
-
Mass Spectrometric Identification of 13C-Labeled Metabolites DuringAnaerobic Propanoic Acid Oxidation
PublicationBiowaste digestion is a possibility to gain biogas as a renewable fuel source. However, the anaerobic food chain may be disrupted by, e.g., substrate overload or by inhibitors, leading to the accumulation of volatile fatty acids (VFAs), predominantly of propanoic acid (PA). VFA Accumulation may cause a rapid pH decrease, less biogas production, or even a total inhibition. To maintain high biogas productivity or to prevent a collapse...
-
Mass spectrometric identification of 13C-Labeled metaboloites during anaerobic propanoic acid oxidation
PublicationBiowaste digestion is a possibility to gain biogas as a renewable fuel source. However, the anaerobic food chain may be disrupted by, e.g., substrate overload or by inhibitors, leading to the accumulation of volatile fatty acids (VFAs), predominantly of propanoic acid (PA). VFA Accumulation may cause a rapid pH decrease, less biogas production, or even a total inhibition. To maintain high biogas productivity or to prevent a collapse...
-
Innovative Turbine Intake Air Cooling Systems and Their Rational Designing
PublicationThe improved methodology of the engine intake air cooling system designing based on the annual effect due to cooling was developed. It involves determining the optimal value of cooling capacity, providing the minimum system sizes at maximum rate of annual effect increment, and its rational value, providing a close to maximum annual effect without system oversizing at the second maximum rate of annual effect increment within the...
-
PERS - QUIET ROAD SURFACE FOR URBAN AREAS
PublicationTraffic noise is one of the most important environmental problems in densely populated urban areas. At low speeds the tyre/road interaction dominates all other sources. It is anticipated that when electric and hybrid vehicles gain dominance in city traffic, the importance of tyre/road noise will still increase as electric engines are much less noisy than combustion engines. On the other hand, electric and hybrid urban vehicles...
-
Non-linear circuit model of a single doubly-fed induction machine formulated in natural axes for drive systems simulation purposes
PublicationMathematical modelling and a circuit model formulated in natural axes of a single doubly-fed induction machine, with the account of magnetic circuit nonlinearity are presented in the paper. Derivation of the model differential equations was based on Lagrange's energy method. State functions of magnetic elements in the model are non-linear and depend on all currents flowing in the machine windings and on the angle of rotor position....
-
Application of wireless communication to small WECS with induction generator
PublicationWind energy conversion systems (WECS) seem to be self-evident elements of the future smart grids. Among many generator types the squirrel cage induction generator (SCIG) characterizes robustness and low cost. A full-scale power converter can perform smooth grid connection over wide speed range of multiple-stage geared SCIG. Increasing number of sensors can improve the WECS control and diagnostics but increasing number of thin wires...
-
Review of hydrogen production technologies for automotive sector – thermodynamic analysis of energy and exergy losses
PublicationFew recent years has shown that hydrogen technology has a good chance to replace petroleum technology in automotive sector. However, hydrogen in pure form practically does not occur on Earth. That is why H2 form is used only as an energy carrier and it must be produced using another source of energy form water or hydrocarbon fuels. In this paper short overview of hydrogen production technology has been presented, with energy and...
-
Composite Sandwich Footbridge – Numerical ESL FEM Calculations vs. In Situ Measurements
PublicationSelected results of the static analysis of composite sandwich footbridge with the corresponding in situ measured values are compared in the paper. The analysed bridge is a research object, which was built in 2015 and is currently located at the Gdańsk University of Technology campus. Since it is a novel structure, a proper definition of the bridge numerical model, allowing its safe design, is very important. Therefore, instead...
-
Description Logic As A Common Software Engineering Artifacts Language
PublicationDescription logic is proposed as a powerful language able to support chosen software engineering process tasks like: requirements engineering, software architecture definition, software design and configuration management. To do this there is presented a correspondence between description logic and UML. Description logic based integrated software engineering process framework is proposed which owing to automatic knowledge inferring...
-
Outlet Flow Velocity In Circular Culvert
PublicationThe outlet flow velocity in the end section of the culvert barrel depends in most cases on the culvert geometry, including the barrel slope, as well as on upstream and downstream channel parameters. Flowing water can create pressure flow or free surface flow in the culvert barrel. In the case of an unsubmerged barrel outlet, the free-surface flow is more frequent than the full flow. Increased velocities can cause channel bed scour...
-
Ultrasound monitoring for evaluation of damage in reinforced concrete
PublicationThe paper deals with automated monitoring of damage evolution in concrete elements subjected to three-point bending tests. The monitoring is based on the nonlinear interactions of traveling ultrasonic waves with micro-crack zones inside the concrete specimens and surface-breaking cracks. The developed procedure assumes semi-continuous ultrasonic testing during the element full loading cycle and generation of the power spectral...
-
Efficient synthesis and antifungal investigation of nucleosides’ quaternary ammonium salt derivatives
PublicationQuaternary ammonium salts are a group of compounds with diverse biological properties, the most important of which are their antiviral, antibacterial, and antifungal activities. The quaternization reactions of 5'-O-tosyl derivatives of uridine and thymidine with triethylamine, trimethylamine, 4-(N ,N -dimethylamino)pyridine, 2-methylpyridine, and pyridine are described in this article. Two of the synthesized compounds are exceptional...
-
Comments on various extensions of the Riemann–Liouville fractional derivatives : About the Leibniz and chain rule properties
PublicationStarting from the Riemann–Liouville derivative, many authors have built their own notion of fractional derivative in order to avoid some classical difficulties like a non zero derivative for a constant function or a rather complicated analogue of the Leibniz relation. Discussing in full generality the existence of such operator over continuous functions, we derive some obstruction Lemma which can be used to prove the triviality...
-
Human Centric Lighting. The New X Factor?
PublicationWe live in challenging times, and one could even claim we’re experiencing a revolution in lighting with LED technology taking over the world. Part of this rapid change involves a concept called Human Centric Lighting (HCL). In Frankfurt this year, during Light+Building, it was the buzzword, with nearly every second manufacturer’s stand claiming they had figured out the special formula necessary to create perfect HCL illumination....
-
Robustness of contact-less optical method, used for measuring contact wire position in changeable lighting conditions
PublicationThe article presents verification of robustness of contactless method based on 2D image camera, which is used to measure catenary contact wire position in changeable ambient lighting conditions. Robustness in changeable lighting conditions is ensured through the combination of advanced image processing for background information removal and the algorithm of error correction. This algorithm detects incorrect images and substitutes...
-
Design of novel microstrip directional coupler for differential signal decoupling
PublicationThis study describes a concept of a novel microstrip directional coupler for differential signal decoupling, which can be used to digital signal overhearing on printed-circuit-boards. The complete design method is proposed with rules given analytically. Considered methodology is suitable for synthesis of couplers with low coupling factors, which have negligible influence on the transmission in main line. Theoretical considerations...
-
The role of robotisation in improving bakery product quality
PublicationThe article aims to present the role of robotisation in increasing bakery product quality, as it is closely linked to machine reliability, as well as hygienic and sanitary conditions. All machines employed in the production process ought to be maintained at full production potential and reliability, which also has a fundamental influence on the final product’s quality. While participating in the 2014-2020 Smart Growth Operational...
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014738131]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014734381]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014727091]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014735321]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [9270729565544651]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [3300730069437711]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014731971]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [609073001473801]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014735071]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014731451]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [609073001473271]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014737341]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014734621]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014739561]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [9270729565545011]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [609073001472871]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014736251]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014736981]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [927072956554981]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [3300730069431061]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014732901]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [9270729565546121]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014734071]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014738971]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [9270729565547731]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [9270729565544511]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [9270729565541701]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [9270729565542261]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute lymphadenitis, unspecified - Female, 10 - Tissue image [927072956554661]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014731541]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014738071]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal histological findings - Female, 49 - Tissue image [6090730014731951]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.