Publications
Filters
total: 816
Catalog Publications
Year 2016
-
An electronic nose for quantitative determination of gas concentrations
PublicationThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequen tly, there is considerable need for an instrument that can be a substitution of the human sense of smell. Electronic nose devices from the mid 1980s are used in growing number of applications. They comprise an array of several electrochemical gas sensors...
-
Analysis of the parameters of respiration patterns extracted from thermal image sequences
PublicationRemote estimation of vital signs is an important and active area of research. The goal of this work was to analyze the feasibility of estimating respiration parameters from video sequences of faces recorded using a mobile thermal camera. Different estimators were analyzed and experimentally verified. It was demonstrated that the respiration rate, periodicity of respiration, and presence and length of apnea periods could be reliably...
-
Balance recognition on the basis of EEG measurement.
PublicationAlthough electroencephalography (EEG) is not typically used for verifying the sense of balance, it can be used for analysing cortical signals responsible for this phenomenon. Simple balance tasks can be proposed as a good indicator of whether the sense of balance is acting more or less actively. This article presents preliminary results for the potential of using EEG to balance sensing....
-
Barium boron aluminum silicate glass system for solid state optical gas sensors
PublicationRecent increasing demand for new eco-friendly materials and for low cost fabrication process for use in optical sensors field, raise concern about alternative materials for this application. We have designed two glass-ceramics compositions from the quaternary ROAl2O3- SiO2-B2O3(R=Ba) alkali-earth aluminum silicate system, labeled B72 and B69, with high refractive index (>1.6), large values of Abbe number (94.0 and 53.0, respectively),...
-
Cardiovascular data analysis using electronic wearable eyeglasses-preliminary study
Publicationhe paper presents an alternative approach to the monitoring of the cardiovascular system. The study depicts configurations of the utilized system and preliminary results of electrical and mechanical parameters of the cardiac system which can be measured using a head-worn device.
-
CGO as a barrier layer between LSCF electrodes and YSZ electrolyte fabricated by spray pyrolysis for solid oxide fuel cells
PublicationPerovskite La0.6Sr0.4Co0.2Fe0.8O3 − δ (LSCF) is often used as a cathode material for solid oxide fuel cells (SOFC) due to high mixed ionic and electronic conductivity and good catalytic activity. Unfortunately, sintering of the LSCF cathode together with the yttria stabilized zirconia (YSZ) electrolyte, leads to formation of the La2Zr2O7 and SrZrO3 phases in the interface. These phases increase the resistance of the cell. To avoid...
-
Comparison of perforator location in dynamic and static thermographic imaging with Doppler ultrasound in breast reconstruction surgery
PublicationThis paper co mpares the effectiveness of the dTnorm and t90_10 parametrizations in dynamic thermography for imaging location of perforators in TRAM flaps in the intraoperative period. The results were compared with the location detected in a Doppler ultrasound examination. Cold and heat stimulation was used in dynamic thermography. Additionally, these results were compared with static...
-
Conductivity and viscosity changes of imidazolium ionic liquids induced by H2O and CO2
PublicationSeveral solutions of ionic liquids based on 1-ethyl-3-methylimidazolium cation saturated and unsaturated with carbon dioxide were prepared and characterized by electrochemical impedance spectroscopy. The in fluence of ILs saturation on its electrical conductivity was determined. Additionally, the in fluence of the water presence and variations of temperature on electrical properties of ionic liquids were investigated. Changes of...
-
Detekcja osoby w wannie
PublicationStarzenie się społeczeństwa powoduje narastanie problemów chorób wieku starczego. Częstym problemem są zasłabnięcia w wannie podczas kąpieli. Celem publikacji jest przedstawienie metody identyfikacji tkanki ożywionej w wodzie z wykorzystaniem technik elektromagnetycznych. Obserwując zmiany amplitudy i częstotliwości pracy generatorów, pracujących w pętli sprzężenia zwrotnego z cewką, istnieje możliwość scharakteryzowania i określenia...
-
Detekcja osoby w wannie
PublicationStarzenie się społeczeństwa powoduje narastanie problemów chorób wieku starczego. Częstym problemem są zasłabnięcia w wannie podczas kąpieli. Celem publikacji jest przedstawienie metody identyfikacji tkanki ożywionej w wodzie z wykorzystaniem technik elektromagnetycznych. Obserwując zmiany amplitudy i częstotliwości pracy generatorów, pracujących w pętli sprzężenia zwrotnego z cewką, istnieje możliwość scharakteryzowania i określenia...
-
Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
PublicationA periodic temperature modulation using sinusoidal heater voltage was applied to a commercial SnO2 semiconductor gas sensor. Resulting resistance response of the sensor was analyzed using a feature extraction method based on Fast Fourier Transformation (FFT). The amplitudes of the higher harmonics of the FFT from the dynamic nonlinear responses of measured gas were further utilized as an input for Artificial Neural...
-
Determination of the ionic conductivity of Sr-doped lanthanum manganite by modified Hebb–Wagner technique
PublicationThe Hebb–Wagne rpolarization method with the electron blocking electrode has been discussed in this paper in aim to determine a partial ionic conductivity of Sr-doped lanthanum manganite.The “limiting current” in the proposed system was measured using the two-point DC technique with additional Pt electrode between LSM and blocking electrode.The electrochemical model based on bulk diffusion processes and Boltzmann statistics has...
-
Electrochemicalsynthesis of 3D nano-/micro-structured porous polypyrrole
PublicationIn this work, electrosynthesis of electroactive, 3D nano-/micro-structured porous polypyrrole film is presented. The PPy film was synthesized potentiostatically in a one-step process from aqueous solution of pyrrole and lithium perchlorate. The growth mechanism of such structure included: the formation of typical globular PPy film, followed by the formation of the PPy fibers, which then took part in the formation of 3D highly porous...
-
EMG and gaze based interaction with graphic interface of smart glasses application
PublicationIn this paper we investigate the effectiveness of the interaction using eye tracking and electromyography. Smart glasses requires reliable interfaces for controlling the graphic content displayed directly in front of the user's eye. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of...
-
Enhanced Eye-Tracking Data: a Dual Sensor System for Smart Glasses Applications
PublicationA technique for the acquisition of an increased number of pupil positions, using a combined sensor consisting of a low-rate camera and a high-rate optical sensor, is presented in this paper. The additional data are provided by the optical movement-detection sensor mounted in close proximity to the eyeball. This proposed solution enables a significant increase in the number of registered fixation points and saccades and can be used...
-
Estimation of blood pressure parameters using ex-Gaussian model
PublicationThe paper presents an example of model-based estimation of blood pressure parameters (onset, systolic and diastolic pressure) from continuous measurements. First, the signal was low pass filtered and its quality was estimated. Good quality periods were divided into beats using an electrocardiogram. Next, the beginning of each beat of the blood pressure signal was approximated basing on the function created from the sum of two independent...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublicationRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublicationIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
-
Evaluation of respiration rate and pattern using a portable thermal camera
PublicationThe goal of this paper was to analyze the accuracy of the proposed method for the evaluation of respiration rate and respiration rhythm patterns (e.g. inspiration slope) using the portable and mobile thermal camera module that could be a part of smart glasses. Parameters were analyzed for 12 volunteers in two experiments, when subjects speak and do not speak. The pressure, chest belt was used as a reference measurement method....
-
Extraction and evaluation of gas-flow-dependent features from dynamic measurements of gas sensors array
PublicationGas analyzers based on gas sensors are the devices which enable recognition of various kinds of volatile compounds. They have continuously been developed and investigated for over three decades, however there are still limitations which slow down the implementation of those devices in many applications. For example, the main drawbacks are the lack of selectivity, sensitivity...
-
Face detection in image sequences using a portable thermal camera
PublicationFace detection is often a first step in quantitative analysis of face images. It is an important research area for visible images and recently also for thermography. Due to technological developments thermal cameras may be embedded into wearable devices to provide remote healthcare. In this paper, we compared three algorithms for face detection in thermal images by testing execution time, accuracy, symmetry ratio and false-positives....
-
Features extraction from the electrocatalytic gas sensor responses
PublicationOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Gas sampling system for matrix of semiconductor gas sensors
PublicationSemiconductor gas sensors are popular commercial sensors applied in numerous gas detection systems. They are reliable, small, rugged and inexpensive. However, there are a few problem limiting the wider use of such sensors. Semiconductor gas sensor usually exhibits a low selectivity, low repeatability, drift of response, strong temperature and moisture influence on sensor properties. Sample flow rate is one of the parameters that...
-
Graphene oxide, reduced graphene oxide and composite thin films NO2 sensing properties
PublicationA graphene oxide (GO), reduced graphene oxide (RGO) and poly(3,4-ethylenedioxytiophene)-reduced graphene oxide (PEDOT-RGO composite) gas sensors were successfully fabricated using an electrodeposition method. The electrodeposition was carried out in aqueous GO dispersions. To obtain RGO and PEDOT-RGO, the electrochemical reduction of GO and PEDOT-GO was carried out in 0.1 M KCl at a constant potential of −0.85 V. The GO, RGO and PEDOT-RGO...
-
High Temperature Corrosion Evaluation of Porous Hastelloy X Alloy in Air and Humidified Hydrogen Atmospheres
PublicationIn this work a commercially available porous Hastelloy X alloy is characterized in terms of high temperature corrosion resistance. The alloy was oxidized in the temperature range from 500C to 900C in air and humidified hydrogen for 100 hours. Corrosion rates and porosity changes were measured. Microstructural characterization was performed using X-ray diffractometry and scanning electron microscopy. Results show that porous alloys...
-
Increased inspiratory resistance alters the cardiac contribution to the dynamic relationship between blood pressure and pial artery pulsation oscillations in healthy subjects
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance will affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Influence of Sb-substitution on ionic transport in lanthanum orthoniobates
PublicationThe results of ionic transport measurements for the lanthanum orthoniobate substituted with 10 and 30 mol% of antimony (LaNb0.9Sb0.1O4 and LaNb0.7Sb0.3O4) are presented and discussed. The influence of calcium co-doping on these properties has also been analysed. It has been shown that for the investigated material protonic conductivity predominates at temperatures up to 800 °C in oxidizing atmospheres under wet conditions. The...
-
Inteligentne otoczenie w aplikacjach prozdrowotnych - przykłady rozwiązań
PublicationW artykule przedstawiono koncepcję inteligentnego otoczenia jako wyposażenia tzw inteligentnego budynku ukieunkowanego na wspomaganie diagnostyki medycznej osób zagrożonych określonymi chorobami. Przedstawiono bliżej dwa rozwiązania – układ inteligentnej wagi i krzesła kardiologicznego.
-
Inteligentne otoczenie w aplikacjach prozdrowotnych - przykłady rozwiązań
PublicationW artykule przedstawiono koncepcję inteligentnego otoczenia jako wyposażenia tzw inteligentnego budynku ukieunkowanego na wspomaganie diagnostyki medycznej osób zagrożonych określonymi chorobami. Przedstawiono bliżej dwa rozwiązania – układ inteligentnej wagi i krzesła kardiologicznego.
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublicationIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
-
Laser patterned platform with PEDOT–graphene composite film for NO2 sensing
PublicationThis work presents a simple and fully electrochemical route used for fabricating of a NO2 gas sensor made of reduced-graphene-oxide-poly(3,4-ethylenedioxythiophene) composite film. The sensing platform was fabricated from alumina substrate and equipped with gold interdigitated electrodes and built-in heater.The temperature distribution on the surface of interdigitated electrodes was investigated by a thermalimaging camera and compared...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublicationThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
Low temperature processed MnCo2O4 and MnCo1.8Fe0.2O4 as effective protective coatings for solid oxide fuel cell interconnects at 750 °C
PublicationIn this study two materials, MnCo2O4 and MnCo1.8Fe0.2O4 are studied as potential protective coatings for Solid Oxide Fuel Cell interconnects working at 750 °C. First powder fabrication by a modified Pechini method is described followed by a description of the coating procedure. The protective action of the coating applied on Crofer 22 APU is evaluated by following the area specific resistance (ASR) of the scale/coating for 5500...
-
Metrological characteristics of the flat voltammetric electrode in time domain with a reversible electrochemical reaction running on the surface
PublicationW artykule przedstawiono właściwości metrologiczne płaskich elektrod woltamperometrycznych. Omówiono wpływ napięcia polaryzującego na wartości parametrów charakteryzujących te elektrody.
-
Multichannel Human Body Communication
PublicationHuman Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog...
-
Performance Analysis of Interaction between Smart Glasses and Smart Objects Using Image-Based Object Identification
PublicationWe propose the use of smart glasses to collaborate with smart objects in the Internet of Things environment. Particularly we are focusing on new interaction methods and the analysis of acceptable reaction times in the process of object recognition using smart glasses. We evaluated the proposed method using user studies and experiments with three different smart glasses: Google Glass, Epson Moverio, and the developed eGlasses platform....
-
[PP.17.01] INCREASED INSPIRATORY RESISTANCE AFFECTS THE CARDIAC CONTRIBUTION TO THE RELATIONSHIP BETWEEN BLOOD PRESSURE AND PIAL ARTERY PULSATION OSCILLATIONS
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance would affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Real-time facial feature tracking in poor quality thermal imagery
PublicationRecently, facial feature tracking systems have become more and more popular because of many possible use cases. Especially in medical applications location of the face and facial features are very useful. Many researches have presented methods to detect and track facial features in visible light. However, facial feature analysis in thermography may also be very advantageous. Some examples of using infrared imagery in medicine include...
-
Reliability of Pulse Measurements in Videoplethysmography
PublicationReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
Self diagnostics using smart glasses - preliminary study
Publicationn this preliminary study we analyzed the possibility of the reliable measurement of biomedical signals with some potential hardware extensions of smart glasses. Using specially designed experimental prototypes four category of biomedical signals were measured: electrocardiograms, electromyograms, electroencephalograms and respiration waveforms. Experi- ments with volunteers proved that using even simple construc- tion of sensors...
-
Semi complex navigation with an active optical gesture sensor
PublicationThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
Stanowisko do aktywnej termografii dynamicznej do diagnostyki medycznej
PublicationW artykule omówiono budowę zestawu diagnostycznego metodą aktywnej termografii dynamicznej w medycznych aplikacjach takich jak: diagnostyka oparzeń, monitoring gojenia się ran pooperacyjnych oraz monitoring w kardiochirurgii. Podstawowy zestaw składa się z układu formowania wymuszenia termicznego w postaci nadmuchu schłodzonej mieszaniny gazów CO2 oraz powietrza lub tylko schłodzonego powietrza, układu akwizycji sekwencji termograficznych,...
-
Study of the electrochemical stability of polypyrrole coating on iron in sodium salicylate aqueous solution
PublicationIn this work electrochemical stability of optimized PPy film on iron in aqueous solution of sodium salicylate is studied. The main drawback of conducting polymers is their possibility to undergo an irreversible degradation (overoxidation). The overoxidized polymers lose their properties, for example, conductivity and redox activity, what excludes them from some practical applications. This study demonstrates that lowering the concentration...
-
Techniques of acquiring additional features of the responses of individual gas sensors
PublicationGas sensors usually exhibit lack of selectivity, require fre quent calibration, exhibit drift of the response and a lot of factors, such as humidity or ambient temperature, influen ce their performance. Different approaches can be used to overcome this shortcomings. Building arrays of different sensors and usage of pattern recognition methods to analyze responses of elements...
-
The accuracy of pulse rate estimation from the sequence of face images
PublicationThe goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...
-
The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard
PublicationIn this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...
-
The determinants of morphology and properties of the nanohydroxyapatite coating deposited on the Ti13Zr13Nb alloy by electrophoretic techniqe
PublicationThe titanium and its alloys belong at present to the most preferred and commonly applied biomaterials for load- bearing implants. The surfaces of biomaterials are subjected to modification, including the hydroxyapatite coatings deposited in order to ensure corrosion resistance and better joining between an implant and a bone through the possibility of ingrowth bone into the coating. In this paper, the morphology and properties...
-
The evaluation of eGlasses eye tracking module as an extension for Scratch
PublicationIn this paper we present the possibility of using eGlasses eye tracking module as an extension for Scratch programming tool which is a visual programming language supporting computer skills learning. The main concept behind this project is to setup the interface for rapid interaction design. Eye tracking is a powerful tool for hands free communication but for that requires a dedicated software. This software is rarely tailored...
-
The Evaluation of Use of Colors in Graphical User-Interfaces in Healthcare
PublicationIn this paper, color difference/contrast measures are investigated in reference to results of experiments with the participation of average, color-normal observers and with individuals with deuteranopia. Additionally, a new method for the automatic analysis of color contrast is proposed, which supports designers of graphical user- interfaces in healthcare. The method was verified using the GUI phantom of a vital signs monitor (the...
-
THE ROLE OF THIN FUNCTIONAL LAYERS IN SOLID OXIDE FUEL CELLS
PublicationWidespread commercialization of solid oxide fuel cells requires lowering its cost. It is generally accepted that to lower the cost of solid oxide fuel cells it is necessary to use metal alloys as interconnectors and, consequently, lower its operating temperature to slow down interconnectors degradation. As a result the area specific resistance of the cathodes should be lowered to sustain the performance of the cells. In order to...