Research on causes of corrosion in the municipal water supply system
PublikacjaThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
-
Hydrogen-enhanced stress corrosion cracking and corrosion fatigue of HSLA steels in sea-water
PublikacjaPrzedstawiono ocenę podatności stali o wysokiej wytrzymałości na naprężeniowe pękanie korozyjne i zmęczenie korozyjne wspomagane przez wodór. Wykonano próby powolnego rozciągania i zmęczenia niskoczęstotliwościowego na stalach 17HMBVA i 14HNMBCu oraz ich złączach spawanych, w środowisku wody morskiej, przy polaryzacji katodowej. Zamieszczono wyniki badań elektrochemicznych oraz przełomów na skaningowym mikroskopie elektronowym.
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublikacjaThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
Korozja rur ciepłowniczych = Heat water tubes corrosion
PublikacjaZbadano uszkodzenia korozyjne instalacji ciepłowniczej w aspekcie jakości rur zgrzewanych i korozyjności wody sieciowej. Rury przewodowe ze stali niskowęglowej zostały zniszczone przez korozję wżerową/podosadową zlokalizowaną w obszarze połączenia zgrzewanego wskutek nieodpowiedniej jakości wody.
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
Publikacja -
Sodium nitrite as a corrosion inhibitor of copper in simulated cooling water
PublikacjaThe corrosion inhibition behavior of sodium nitrite (NaNO2) towards pure copper (99.95%) in simulated cooling water (SCW) was investigated by means of electrochemical impedance spectroscopy (EIS) and dynamic electrochemical impedance spectroscopy (DEIS). NaNO2 interferes with metal dissolution and reduce the corrosion rate through the formation or maintenance of inhibitive film on the metal surface. Surface morphologies illustrated...
-
DETERMINATION OF THE EFFECT OF ENVIRONMENTAL FACTORS ON THE CORROSION OF WATER DISTRIBUTION SYSTEM BASED ON ANALYSIS OF ON-LINE CORROSION MONITORING RESULTS
PublikacjaCorrosion of water distribution system is a significant issue causing problems with quality, safety and continuity of distribution. The changes of corrosion rates of the water distribution systems in Cracow made of carbon steel were investigated by analysis of online corrosion monitoring system results. Corrosion rates were determined using the linear polarization method. The impact of rain, temperatures, conductivity, dissolved...
-
Influence of water salinity on corrosion risk - the case of the southern Baltic Sea coast.
PublikacjaWater corrosivity in Gdansk Bay, Poland, the southern part of the Baltic Sea, was investigated. The analysed region is heavily industrialized, and the coastline is very diverse. Twenty-seven test points along the coastline were selected. Water parameters such as salinity, total dissolved solids content, resistivity, conductivity, oxygenation, pH and corrosion rate were determined. The results of the investigation are presented....
-
Determination of causes of accelerated local corrosion of austenitic steels in water supply systems
PublikacjaThis paper concerns an inspection of a water supply system, made of AISI 304 steel, which showed signs of local corrosion at the weld. Such corrosion caused material perforation after very short periods of operation. It was revealed that steel was sensitised during the welding process. It was also proven that chromium micro-segregation occurred in the alloy leading to galvanic cell formation which initialised the process of pitting...
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublikacjaCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...