Filtry
wszystkich: 597
wybranych: 31
-
Katalog
- Publikacje 452 wyników po odfiltrowaniu
- Czasopisma 55 wyników po odfiltrowaniu
- Konferencje 2 wyników po odfiltrowaniu
- Osoby 4 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Kursy Online 4 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 77 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: CELLULAR REDOX SIGNALLING
-
The study of the influence of ZnO nanoparticles on pyocyanin production - the optimization of production and the study of the physiological response of the cells
Dane BadawczeThis dataset presents the in-depth analysis of the influence of zinc oxide nanoparticles on pyocyanin production.
-
The complete list of two-dimensional number-conserving ternary cellular automata
Dane BadawczeThis dataset contains a complete list of all 1327 two-dimensional number-conserving cellular automata with the state set {0,1,2} (the so-called ternary cellular automata) based on adjacent cells only, i.e. with the von Neumann neighborhood. The detailed definitions and the method of enumerating are given in the paper:
-
The complete lists of 1D reversible number-conserving cellular automata with radius one of up to 7 states
Dane BadawczeThis dataset contains complete lists of all one-dimensional reversible number-conserving k-ary cellular automata with radius one of up to 7 states, i.e. with state sets {0,1}, {0,1,2}, {0,1,2,3}, {0,1,2,3,4}, {0,1,2,3,4,5} and {0,1,2,3,4,5,6}.
-
The complete list of two-dimensional rotation-symmetric number-conserving septenary cellular automata
Dane BadawczeThis dataset contains a complete list of all 30144 two-dimensional rotation-symmetric number-con-serving cellular automata with the state set {0,1,2,3,4,5,6} based on adjacent cells only, i.e. with the von Neumann neighborhood. The detailed definitions and the method of enumerating are given in the paper:
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer LNCaP cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer LNCaP cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer H460 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer H460 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal PNT1A cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal PNT1A cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer Du-145 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer Du-145 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal MRC-5 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal MRC-5 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
Analysis of cellular senescence following anthraquinone treatment in A549, H226, and H460 cells
Dane BadawczeThe datasets comprise microscopic images of A549, H226, and H460 cells following treatment with anthraquinones and staining with senescence-associated β-galactosidase. The images were captured using an Olympus BX60 microscope (Tokyo, Japan).
-
Electrochemical studies for screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Dane BadawczeThis dataset contains electrochemical examination of SPCE paste and SPCE containing boron-doped diamond BDD foils. The studies include kinetics analyses with cyclic voltammetry and electrochemical impedance spectroscopy with different redox probes: hexacyanoferrate(III) and Hexaammineruthenium(III) and potentiostatic open circuit potential at different...
-
Partial PLA composite surface activation by femtosecond laser ablation
Dane BadawczeThe dataset contains the studies on electrochemical activity of PLA composite (commercially available CB-PLA Protopasta), which was 3D printed in a form of 1x1cm electrodes. The electrodes were submitted to femtosecond laser ablation, etching a certain % of the electrochemically-exposed electrode size. The % value is in the name of each file. The goal...
-
Raman spectra and electrochemical data of carbon nanowall with tailored defects
Dane BadawczeThis dataset comprises of Raman spectra aquired with different excitation laser sources and the electrochemical data of defect-induced carbon nanowall electrodes (CNW).
-
New 3D printable filaments with nanodiamonds, physicochemical additives characteristics and electrochemical activity
Dane BadawczeThis dataset contains the physicochemical analyses (XRD, Raman spectroscopy, BET analyses) and electrochemical analyses (CV, EIS) for a new 3D-printable composite has been developed dedicated to electroanalytical applications. Two types of diamondised nanocarbons - detonation nanodiamonds (DNDs) and boron-doped carbon nanowalls (BCNWs) - were added...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion with different times and concentrations
Dane BadawczeThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K. DIfferent proteinase K concentrations and digestion times were evaluated, as described in subfolder names. The studies were performed before surface activation, during...
-
Electrochemical studies of poly(lactic acid)-carbon black-nanodiamond composites
Dane BadawczeThis dataset contains electrochemical investigation on electrodes 3D printed using a new composite composed of poly-lactic acid (PLA), carbon black (CB) and nanodiamond fillers. Two types of nanodiamonds were studied: detonation nanodiamonds (DND) and boron-doped carbon nanowalls (BCNW). The presented results contain:1. electrochemical characterisation...
-
The electrochemical studies of CB-PLA surface activation by electrolysis in 1M NaOH
Dane BadawczeThe dataset contains the electrochemical studies performed under different conditions of surface activation of the CB-PLA 3D printed electrodes. The activation was performed by electrolysis in 1M NaOH solution under cycling polarization with different anodic or cathodic overpotentials (data in different subfolders). The file names contain the exact...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion
Dane BadawczeThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K (72h digestion period). Different enzyme concentrations were evaluated: 0.2, 0.4, 0.6 and 0.8 mg/ml. The studies were performed before surface activation, during and...
-
The biotic and abiotic mercury at the coastal zone of Gulf of Gdańsk
Dane BadawczeConcentration of neurotoxin Hg (mercury) was determined monthly form 01.2012 to 05.2013 (total and suspended) in the surface microlayer and the surface water as well as in: phytoplankton, zooplankton, epilithon, epifithon, phytobenthos (macroalgae and angiosperms), zoobenthos, and in the sediment. The study was conducted in the coastal zone of the Puck...
-
The cyclic voltammetry studies of CB-PLA electrode after surface activation by electrolysis in 1M NaOH
Dane BadawczeThe dataset contains the electrochemical studies performed for surface activation of the CB-PLA 3D printed electrodes by electrolysis in 1M NaOH solution. The studies were performed after treatment at an anodic overpotential of 1V, found to be optimal for surface activation. The measurements were carried out with cyclic voltammetry (CV) under different...
-
Chromium FTW dataset
Dane BadawczeThis dataset contains the results of chromium and nutrients (N and PO4-P) removal in floating treatment wetland microcosm experiment with two cosmopolitan species of parennials: Phragmites australis and Iris pseudacorus.
-
Surface activation by cyclic polarization in 1M HCl and its effects on the electrochemical response of CB-PLA 3D printed electrodes
Dane BadawczeThe dataset contains the electrochemical studies performed for surface activation of the CB-PLA 3D printed electrodes by electrolysis in 1M HCl solution. The studies were performed after treatment at different polarization ranges, as labeled in subfolder names. For each electrode the consecutive studies describe different samples, as labeled in subfolders:...
-
Partial PLA composite surface activation by femtosecond laser ablation
Dane BadawczeThe dataset contains the studies on electrochemical activity of PLA composite (commercially available CB-PLA Protopasta), which was 3D printed in a form of 1x1cm electrodes. The electrodes were submitted to femtosecond laser ablation operating with different parameters. These were: gas atmosphere (He or air, data in different subfolders), the percentage...
-
Measurement data of cyclic voltammetry and electrochemical impedance measurements of carbon samples synthesized on axes and off axes
Dane BadawczeThe electrochemical performance of the multielectrode samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using a VMP-300 BioLogic galvanostat potentiostat (France) under the EC-lab software. All electrochemical investigations were carried out in a three-electrode cell system. The carbon multi-electrode,...
-
Determination of cytotoxic activity of new bisacridines IKE18, IKE19, IKE21 and IE10 against human kidney HEK-293 (ATCC® CRL-1573™) and liver cells HEPG2 (ATCC® HB-8065™)
Dane BadawczeThe datasets contain the results of determining in vitro cytotoxic activity of compounds using human cell lines assessed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, a method that evaluates cell viability by measuring cellular oxidoreductase activity. Initially, cells were seeded in 96-well culture plates and allowed...
-
The electrochemical studies of thin boron-doped diamond films deposited at conductive poly(lactic acid) 3D prints
Dane BadawczeThe dataset contains the electrochemical characteristics of the electrodes composed of thin boron-doped diamond films coated on commercially available graphene-doped polylactide acid. The boron doping level expressed as the [B]/[C] ratio in the gas phase for these studies was 500 and 10,000 ppm.
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Dane BadawczeThis dataset contains Dynamic EIS results obtained for the gold electrodes with non-functionalized gold nanocubes (AuNC) deposited at its surface. The deposition was the following: 2 uL of the solvent containing CTAB as the surfactant was put on the electrode and dried, the same procedure was applied 5 times. Afterward, the electrode was immersed in...
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Dane BadawczeThis dataset contains Dynamic EIS results obtained for the gold electrodes with non-functionalized gold nanocubes (AuNC) deposited at its surface. The deposition was the following: 2 uL of the solvent containing CTAB as the surfactant was put on the electrode and dried, the same procedure was applied 5 times. Afterward, the electrode was immersed in...
-
Polyacrylamide substrate viscosity impact on temozolomide activity in glioblastoma cells by flow cytometry and rheological measurements
Dane BadawczeDataset includes raw data on cell lines LN-229 and LN-18 treated with temozolomide measured by flow cytometry, rheometry and cell projections. It also includes calculations necessary for creation of figures and conclusions based on those figures in the publication titiled: "Substrate viscosity impairs temozolomide-mediated inhibition of glioblastoma...
-
The electrochemical response to glassy carbon electrode modification steps towards viral electrochemical immunosensor preparation
Dane BadawczeThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the glassy carbon GC electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration,...
-
The electrochemical response to Au electrode modification steps towards viral electrochemical immunosensor preparation
Dane BadawczeThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the Au electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration, with...