Filtry
wszystkich: 69
wybranych: 26
Wyniki wyszukiwania dla: T-TYPE INVERTER
-
Losses Model of the WPT System with Single-Phase T-Type Inverter
Publikacja -
Feasibility Study GaN Transistors Application in the Novel Split-Coils Inductive Power Transfer System with T-Type Inverter
PublikacjaA promising solution for inductive power transfer and wireless charging is presented on the basis of a single-phase three-level T-type Neutral Point Clamped GaN-based inverter with two coupled transmitting coils. The article focuses on the feasibility study of GaN transistor application in the wireless power transfer system based on the T-type inverter on the primary side. An analysis of power losses in the main components of the...
-
New type T-Source inverter
PublikacjaThis paper presents different topologies of voltage inverters with alternative input LC networks. The basic topology is known in the literature as a Z-source inverter (ZSI). Alternative passive networks were named by the authors as T-sources. T-source inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage of the T-source inverter (TSI) is its use of a common voltage...
-
New type T-Source inverter
Publikacja -
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublikacjaThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
THREE-LEVEL F-TYPE INVERTER
PublikacjaGiven the recent available IGBT switch modules up to 6.5 kV, 1200 A rating, the prospect of the diode-free variant topology of the three-level neutral-point-clamped (3-level, T-type) inverter in certain medium voltage applications is bright; due to its small part count and low conduction losses compared to the diode-clamped NPC inverter. However, within this voltage range, the input dc voltage rating of 50% of the switches per...
-
Inline Waveguide Filter With Transmission Zeros Using a Modified-T-Shaped-Post Coupling Inverter
PublikacjaThis letter reports the design techniques for a class 2 of inline waveguide bandpass filters with sharp-rejection capabil3 ities at the lower stopband based on a novel nonlinear-frequency4 variant-coupling (NFVC) structure. The proposed NFVC consists 5 of a modified-T-shaped metallic post (MTP) that is placed at the 6 center of the waveguide broad wall with its open arms lying 7 along the waveguide width. The engineered NFVC structure 8...
-
Design of three-phase three-level CIC T-source inverter with maximum boost control
Publikacja -
Retinoic acid‐induced autoantigen‐specific type 1 regulatory T cells suppress autoimmunity
Publikacja -
Inhibition of T-type calcium channel disrupts Akt signaling and promotes apoptosis in glioblastoma cells.
PublikacjaGlioblastoma multiforme (GBM) are brain tumors that are exceptionally resitant to both radio- and chemotherapy regimens and novel approaches to treatment are needed. T-type calcium channels are one type of low voltage-gated channel (LVCC) involved in embryonic cell proliferation and differentiation; however they are often over-expressed in tumors, including GBM. In this study, we found that inhibition of T-type Ca channels in GBM...
-
Factors affecting long-term efficacy of T regulatory cell-based therapy in type 1 diabetes
Publikacja -
Keratinocyte-derived small extracellular vesicles supply antigens for CD1a-resticted T cells and promote their type 2 bias in the context of filaggrin insufficiency
PublikacjaIntroduction: Exosome-enriched small extracellular vesicles (sEVs) are nanosized organelles known to participate in long distance communication between cells, including in the skin. Atopic dermatitis (AD) is a chronic inflammatory skin disease for which filaggrin (FLG) gene mutations are the strongest genetic risk factor. Filaggrin insufficiency affects multiple cellular function, but it is unclear if sEV-mediated cellular communication...
-
Induction of Secreted Human Immunodeficiency Virus Type 1 (HIV-1) Resistance Factors in CD4-Positive T Lymphocytes by Attenuated HIV-1 Infection
Publikacja -
The new type of [Zr6(μ3-O)4 (μ3-OH)4] cluster core: Crystal structure and spectral characterization of [Zr6O4(OH)4(OOCR)12] (R = Bu^t^,C(CH3)2Et)
PublikacjaSześciojądrowe oxo karboksylowe kompleksy cyrkonu(IV) zostały otrzymane z Zr(OR')4 i odpowiednich kwasów organicznych HOOCR (R=t-Bu, CMe2Et) w stosunku molowym 1:2. Struktury krystaliczne dwóch związków o wzorze [Zr6O4(OH)4(OOCR)12] (1 dla R=t-Bu i 2 dla R=-CMe2Et) zostały rozwiązane w grupie przestrzennej R-3. Substancje zostały przebadane termograwimetrycznie (TGA/DTA) oraz przy użyciu spektroskopii w podczerwieni ze zmienną...
-
Single-phase, Five-level Inverter with SPWM-Based Neutral Point Voltage Balancing Scheme
PublikacjaMultilevel inverter topologies provide several advantages over two-level inverter configuration. These benefits are the reason for the growing interest in multilevel topologies among research society. One of the most popular topological concepts (diode and active switch clamping) requires neutral-point potential balancing due to series-connected capacitor banks across the input dc link in such derived inverter configurations. This...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublikacjaThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
PublikacjaThis paper presents different topologies of buck-boost converters with passive input networks that have alternative topologies; this is known in the literature as a Z-source inverter. Alternative passive networks were named by the authors as T-inverters; these improve output voltage regulation of the PWM inverters. T-inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage...
-
Frequency-Variant Double-Zero Single-Pole Reactive Coupling Networks for Coupled-Resonator Microwave Bandpass Filters
PublikacjaIn this work, a family of frequency-variant reactive coupling (FVRC) networks is introduced and discussed as new building blocks for the synthesis of coupled-resonator bandpass filters with real or complex transmission zeros (TZs). The FVRC is a type of nonideal frequency-dependent inverter that has nonzero elements on the diagonal of the impedance matrix, along with a nonlinear frequency-variation profile of its transimpedance...
-
Three-Level Z-Source Neutral-Point-Clamped Inverter
PublikacjaThe paper describes construction and the principles of activity, attributes and potential of 3-phase Z-type inverters. The paper focuses on the basic system and suggested 3-level system of a NPC type Z-inverter, which was elaborated by authors. Simplified theoretical analysis of both systems has been verified by detailed simulation research. In the last section of the article, the possibility to build multilevel Z- inverters based...
-
Sensorless Control of Induction Machine Supplied by Current Source Inverter
PublikacjaThe paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.
-
Integrated Three-Level Dual-Phase Inverter
PublikacjaIn view of reducing the number of inverter legs that provide dual-phase, three-level output voltages (as may be needed in an uninterruptible power supply), and that also provide a wide range of output frequencies (as needed in an advanced motor drive system with wide speed ranges), a three-level, dual-phase inverter topology is presented in this paper. Its three-level attribute was based on the F-type inverter topological concept,...
-
KONCEPCJA DWU-ŚMIGŁOWEJ ELEKTROWNI WIATROWEJ I ELEKTROWNI SZCZYTOWO-POMPOWEJ NA WZGÓRZU SZUBIENICZNYM
PublikacjaDogodne warunki terenowe Wzgórza Szubienicznego w Gdańsku oraz istniejąca tam infrastruktura stanowią podstawę do rozważenia koncepcji doposażenia instalacji badawczej Laboratorium Innowacyjnych Technologii Elektroenergetycznych i Integracji Odnawialnych Źródeł Energii LINTE^2 w skojarzony, hydro-wiatrowy zespół wytwórczy. W artykule zaproponowano koncepcję budowy elektrowni pompowo-szczytowej z turbinami Francisa oraz elektrowni...
-
Wzmocnienie uszkodzonej belki typu T w przęśle wiaduktu drogowego
PublikacjaW artykule opisano metodę wzmocnienia belki prefabrykowanej typu T dźwigara wiaduktu drogowego uszkodzonej przez pojazd „wozidło”. Beton belki uległ zarysowaniom w wielu miejscach. Wystąpiły też ubytki otuliny strun sprężających. Zaproponowano naprawę i wzmocnienie przez dobetonowanie dodatkowej belki. Podczas naprawy zastosowano balastowanie przęsła w celu wciągnięcia nowego dźwigara do współpracy od ciężaru własnego i sprężenia....
-
EMC disturbances in connection of driving system
PublikacjaIt is known the steep voltage changes caused by IGBT frequency inverters may cause some electromagnetic problems in driving system. Special dU/dt type as well as sinusoidal filters are used in order to limit the level of the disturbances. The paper presents investigation results of EMC disturbances in inverter supplied induction motor. Experiments have proved that disturbances in current connection differ essentially. Important...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublikacjaThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
Power Hardware-In-the-Loop Approach for Autonomous Power Generation System Analysis
PublikacjaThe article presents the Power Hardware-In-the-Loop (PHIL) dynamic model of a synchronous generator of 125 kVA for autonomous power generation system analysis. This type of system is typically composed of electrical energy sources in the form of several diesel generator units with synchronous machines, the main distribution switchboard and different loads. In modern power distribution systems, the proposed power management strategies...