Wyniki wyszukiwania dla: klucz
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Evaluation Of Single Pole Auto-Reclosing Effectiveness With Nonlinear Secondary Arc Model
PublikacjaThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a non-linear secondary arc implementation is presented. The authors indicate, that precise representation of secondary electric arc leads to more...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublikacjaThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublikacjaThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublikacjaIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Zabezpieczanie dławika uziemiającego przyłączonego do punktu gwiazdowego dławika kompensacyjnego wysokiego napięcia
PublikacjaW artykule przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Załączono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015 roku, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Analiza napięć indukowanych i strat mocy w kablach elektroenergetycznych wysokiego napięcia dla wybranych sposobów uziemienia żył powrotnych
PublikacjaDostarczanie mocy do centrów miast coraz częściej odbywa się z wykorzystaniem linii kablowych o napięciu 110 kV. To dogodny sposób zasilania, a praktycznie jedyny możliwy w przypadku gęstej zabudowy miejskiej. Kable wysokiego napięcia zawierają współosiową żyłę powrotną, w której podczas normalnej pracy oraz w stanach zakłóceniowych (podczas zwarć) mogą indukować się znaczne napięcia względem ziemi, co zagraża porażeniem i/lub...
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia dla ich wybranych konfiguracji
PublikacjaW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Wybrane problemy detekcji zakłóceń w dławiku uziemiającym przyłączonym do punktu gwiazdowego dławika kompensacyjnego
PublikacjaW referacie przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Przedstawiono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia w wybranych konfiguracjach ich ułożenia
PublikacjaW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Uproszczone modelowanie linii kablowych wysokiego napięcia a napięcia indukowane w żyłach powrotnych – studium przypadku
PublikacjaLinie kablowe, obok linii napowietrznych, są jednym z podstawowych elementów składowych systemów elektroenergetycznych. Stosowane są głównie na terenach zurbanizowanych, gdzie prowadzenie linii napowietrznych jest mocno utrudnione lub wręcz niemożliwe. Linie kablowe wysokiego napięcia budowane są głównie z wykorzystaniem kabli, które oprócz żyły roboczej mają również współosiową żyłę powrotną. Istnieje kilka układów pracy takich...
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublikacjaIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
Ekwiwalentowanie farm wiatrowych
PublikacjaW artykule zaproponowano sposób modelowania i ekwiwalentowania dużych farm wiatrowych. Przedstawiono sposoby tworzenia modeli w celu ich wykorzystania do analiz stanów ustalonych i nieustalonych systemu elektroenergetycznego.
-
Influence of Added Water Mass on Ship Structure Vibration Parameters in Virtual and Real Conditions
PublikacjaModelling of ship structures in a virtual environment is now standard practice. Unfortunately, many engineers forget to consideri the influence of added water on the frequency values and the amplitude of natural vibrations. The article presents the effect of water damping on the frequency values of the individual natural vibration modes. The tests were carried out in two stages. First, the mentioned values were determined using...
-
The characterization of collagen‑based scaffolds modified with phenolic acids for tissue engineering application
PublikacjaThe aim of the experiment was to study the morphology of collagen-based scaffolds modified by caffeic acid, ferulic acid, and gallic acid, their swelling, and degradation rate, as well as the biological properties of scaffolds, such as antioxidant activity, hemo- and cytocompatibility, histological observation, and antibacterial properties. Scaffolds based on collagen with phenolic acid showed higher swelling rate and enzymatic...
-
p-Coumaric acid, Kaempferol, Astragalin and Tiliroside Influence the Expression of Glycoforms in AGS Gastric Cancer Cells
Publikacja -
Synthesis, Pharmacological Evaluation, and Computational Studies of Cyclic Opioid Peptidomimetics Containing β3-Lysine
Publikacja -
Tri(mesityloxy)silanethiol – The First Structurally Characterized Organoxysilanethiol (Contributions to the Chemistry of Silicon–Sulfur Compounds. 77 [1])
Publikacja -
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Tri(mesityloxy)silanethiol - The First Structurally CharacterizedOrganoxysilanethiol (Contributions to the Chemistry of Silicon-SulfurCompounds. 77 [1])
PublikacjaTri(mezytyloksy)silanotiol (TMST) wyizolowano jako jedyny produkt reakcji pomiędzy disiarczkiem krzemu a 2,4,6-trimetylofenolem. TMSTkrystalizuje w układzie trójskośnym. Dobra jakość kryształów pozwoliła na udokładnienie grupy SH bez narzuconych więzów. Długość wiązania S-H określono na 1,29(4) ang., a kąt Si-S-H na 95,4(17) deg. Cząsteczki TMST nie tworzą wiązań wodorowych w kryształach.
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublikacjaIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
Problemy pomiarów mocy i energii w linii elektroenergetycznej Polska-Litwa
PublikacjaW referacie przedstawiono zagadnienia związane z pomiarem mocy i energii w linii dwutorowej. Rozważania oparto na linii łączącej stacje elektroenergetyczne Ełk Bis i Alytus.
-
Wykorzystanie liczników AMI w procesie optymalizacji pracy sieci niskiego napięcia
PublikacjaPrezentowany jest opis projektu dotyczącego m.in. optymalizacji pracy sieci niskiego napięcia przy wykorzystaniu danych z liczników AMI. Prace były prowadzone w ramach europejskiego grantu UPGRID, realizowanego przez konsorcjum firm z siedmiu państw europejskich, w tym również z Polski.
-
Wykorzystanie infrastruktury systemu ami w monitorowaniu i sterowaniu sieciami niskiego napięcia
PublikacjaW referacie przedstawiono wybrane zagadnienia z prac prowadzonych w ramach europejskiego grantu UPGRID realizowanego przez konsorcjum firm z siedmiu państw europejskich, w tym również z Polski, który dotyczy między innymi optymalizacji pracy sieci niskiego napięcia przy wykorzystaniu danych z liczników AMI.
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
Power and energy measurement problems in transmission line between Poland-Lithuania
PublikacjaThe paper discusses problem of power and energy metering in double circuit overhead transmission line. Considerations are based on example of transmission line connecting Polish substation Bis Elk and Lithuanian substation Alytus.
-
Delivery of Ancillary Services in Distribution Power Systems
PublikacjaOne of the technical and organizational challenges the power system faces in deregulated market conditions is to organize an ancillary services market. The growing share of distributed generation of variable (intermittent) energy sources and a change in the market position of consumers, causes the demand for distributed delivery of ancillary services. For this purpose, it is sought to use the ability of the regulatory measures:...
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublikacjaCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
Computer-aided analysis of resonance risk in power system with Static Var Compensators
PublikacjaStatic Var Compensators operation in a power system may significantly improve voltage profiles in nodes and the reactive power balance, as well as ensure greater system stability in emergency conditions. However these devices may be a cause of a resonance in the system. The aim of this paper is to call attention to the need to include resonance phenomena in a compensator’s location evaluation process. The analysis performed in...
-
Influence of Shunt Compensation with SVC Devices on Resonance Risk in Power Systems
PublikacjaMany analyses are required to locate a new reactive power source in a power system. The choice of a location is a very complex matter which requires various aspects to be considered. Selecting a location also entails the necessity to assess it from the point of view of the selected compensator’s structure as well as the system’s performance in various states with the new device on. The paper presents the issues of assessing compensator...
-
Detection of high frequency current components by residual current devices
PublikacjaThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Cross-Bonding of MV Cable Lines for Energy Losses Decrease
PublikacjaCurrently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses...
-
Mechanisms shaping the synergism of zeaxanthin and PsbS in photoprotective energy dissipation in the photosynthetic apparatus of plants
Publikacja -
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublikacjaPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Energy losses reduction in the medium voltage cable line – case study
PublikacjaThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Projekt UPGRID
PublikacjaMiędzynarodowy projekt UPGRID realizowany jest w ramach programu Horyzont 2020 (H2020). Program ten to największy jak dotąd program Unii Europejskiej (UE) w zakresie badań naukowych i innowacji. W projekcie UPGRID uczestniczy 17 partnerów z 9 krajów EU. Głównym celem projektu UPGRID jest rozwój funkcjonalności, które służą integracji sieci nn oraz SN ze stroną konsumencką. W ramach projektu wybrane technologie Inteligentnych Sieci...
-
TRANSFER OF ELECTRIC ENERGY [2023/24]
Kursy OnlineCourse content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...
-
TRANSFER OF ELECTRIC ENERGY [2022/23]
Kursy OnlineCourse content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...
-
TRANSFER OF ELECTRIC ENERGY [2021/22]
Kursy Online -
TRANSFER OF ELECTRIC ENERGY [2024/25]
Kursy OnlineCourse content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...
-
QUICK Kwalifikacje, innowacje, kooperacje i kluczowy biznes w MSP; BSR - QUICK
ProjektyProjekt realizowany w Wydział Zarządzania i Ekonomii zgodnie z porozumieniem #32 z dnia 2009-11-12